Precision Lcr Meter Rlc Digibridge Agilent Lcr Meter Digibridge Agilent Lcr Impedance Analyzer Lcz Meter Impedance Bridge Hp Lcr Meter Lcr Impedance Wayne Kerr Impedance Meter Hp Lcr Hp Impedance Hp Lcz Meter Lcr Bridge Hp 4284A Impedance Bridge Model General Radio Bridge Inductance Rf Impedance Hp 4262A Lcr Meter Vector Impedance Meter Digital Lcr Meter Inductance Bridge Impedance Tester Hp 4192A 4284A Precision Lcr Meter Pcb For Hp Quadtech Agilent 4284A Electro Scientific Capacitor Inductor Genrad Iet Gr Genrad Hp 4275A Multi-Frequency Lcz Meter Capacitance Meter Meter Option Inductor Analyzer Hp 4261A Lcr Meter Rcl Meter Rlc Bridge Genrad Iet 4192A Lf Hp 4193A Pcb For Hp 4275A Multi-Frequency Lcz Hp 8782A Vector Signal Generator Electro Scientific Industries Hp Agilent 4191A 4275A Multi-Frequency Lcr Meter Lcr Meter Battery Impedance 4263B Lcr Meter Lf Impedance Analyzer 4193A Vector Impedance Meter Inductance Capacitance Impedance Tested 4191A Rf Impedance Analyzer Esr Meter Lc Meter 1689 Precision Rlc Digibridge Pcb For Hp 4262A Lcr Meter Capacitor Tester Option 001 Precision Lcr Meter 20 Hz Impedance Stabilization Network 4194A Impedance Gain-Phase Analyzer Opt 001 Hp 4279A 1Mhz C-V Meter Rf Lcr Meter 13 Mhz Line Impedance Stabilization Inductance Meter Hioki 100 Khz Stanford Research Beckman Berkeley Div Impedance Measuring Manual W Schem Lcr Tester Leeds Northrup Ohm Meter Lcr Esr Lcr Esr Meter Inductance Capacitance Meter 1 Mhz 3 Ghz Agilent Agilent Keysight Alligator Clip Clamp Analyzer Opt Bk Precision Boonton Bridge Instructions Manual Capacitor Digital Multimeter Electrical Test Equipment Esi Esr Inductance Resistor Meter Fluke Fluke Multimeter General Radio Ham Radio Handheld Heathkit Hewlett Packard Hp Hp Agilent Hp Spectrum Impedance Inductance Meter Pf Inductance Meter Ph Instruction Manual Instructions Manual Instructions Manual W Schem Keithley Kelvin L Meter Lc Esr Lead Leakage Leakage Tester Maintenance Manual Meter Instructions Manual Meter Model Meter Tested Meter Tester Military Manual Modul Multimeter Not Working Omega Oper Service Manual Oscillator Oscilloscope Parts Or Repair Phillips Power Meter Power Supply Probe Q Meter Radio Model Resistivity Capacitance Resistivity Meter Resistor Sencore Service Manual Signal Generator Spectrum Analyser Spectrum Analyzer Tektronix Lcr Test Equipment Test Equipment Lcr Impedance Tested Fixture Tester Transistor Transistor Tester Esr Tubes Tweezer U1731 U1731c U1732 Uni T Uni-T Ut 511 Vector Vintage General Radio Wavetek Yokogawa Z Meter Handheld Lcr Meter Instruments Test Kelvin Clips In Circuit Esr Meter Smart Tweezers Megger Tester Capacitor Esr Meter Esr Capacitor Tester Oper Instructions Mastech Instruction Manual W Schemat Bridge Oper Instructions Manual W Schematics Transistor Tester Meter Vintage Test Equipment Tested Equip Low Resistance Tested Leads Rohde Schwarz Sme03 Signal Generator Lcr Meter Bench Fluke Lcr Meter
 In 
 
Order by: 
Available to: 
Price: 
 - 
eBay Affiliate Links
$
6990.00
Buy It Now
$85.00 Shipping
Condition: Seller refurbished
Location: Culver City, United States
Quadtech 7600 10 Hz to 2 MHz Precision LCR Meter- CALIBRATED! You are bidding on a Quadtech 7600 10 Hz to 2 MHz Precision LCR Meter with a fresh calibration ... moreperformed in November 2012. The unit will come with a certificate of calibration. The Quadtech 7600 LCR Meter is designed to perform precision impedance measurements over a wide frequency range of 10 Hz to 2 MHz. The instrument is capable of measuring 14 different parameters with 0.05% accuracy to meet today’s requirements for component and material testing. The ease of use and user friendly menu programming makes the 7000 Series ideal for applications in product development. Incoming inspections, or production line testing. PLEASE NOTE THAT THE CABLES AND TEST FIXTURES SHOWN IN THE PICTURES ARE NOT INCLUDED. THESE ACCESSORIES WERE USED TO CALIBRATE THE UNIT, BUT HAVE BEEN SOLD SEPARATELY. Features: Form Factor Benchtop Number of Digits(Max) 7 digits Min. Impedance Measurement 0.01 mOhm Max Impedance Measurement 99.9999 MOhm Minimum Capacitance 0.00001 pF Maximum Capacitance 9.99999 F Min Inductance Measurement 0.001 nH Maximum Inductance 99.9999 H Minimum Frequency 10 Hz Maximum Frequency 2 MHz Minimum Voltage 20 mV Maximum Voltage 5.0 V Minimum Current 250 uA Maximum Current 100 mArms Accuracy 0.05% Internal DC Bias 2 V 0.05% Basic Measurement Accuracy Programmable Test Voltage and Current Auto Ranging Test Setup and Measurement Data Storage Four-Terminal Kelvin Connections Interfaces: IEEE-488 and RS-232 Graphical and Tabular Display 6 Sequence automated testing Load Correction Binning(15) Built-in Automatic Calibration Routine Use for: Production Testing of LCR Components. Frequency Response Characterization of Components, Component Screening, Material Testing, Quality Assurance Testing, Measuring Dielectric Constant Using, Standard Test Cell, etc. You can view the specs for this unit here: This unit is in excellent condition. Has been fully tested and is guaranteed functional. It comes w/ a 5 day right of return should it not perform to your expecta
$
10920.00
Buy It Now
$160.00 Shipping
Condition: New – Open box
Location: 罗湖区, China
We take our reputation seriously.
$
224.00
Buy It Now
$25.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
7018.00
Buy It Now
$160.00 Shipping
Condition: New – Open box
Location: China
Your request will be replied within 12 hours.
$
18135.00
Buy It Now
$160.00 Shipping
Condition: New – Open box
Location: 罗湖区, China
We take our reputation seriously.
$
12200.00
Buy It Now
$150.00 Shipping
Condition: Used
Location: China
We will do our best and help you provide the solution.
$
3500.00
Buy It Now
$65.80 Shipping
Condition: Used
Location: Baltimore, United States
HP/ Agilent 4284A 20Hz-1MHz Precision LCR Meter. Option 001/006 The 4284A/001/006 is in excellent physical and working condition. Includes NIST Calibration ... moreCertificate. The unit is offered with a 14 day right of return and a 30 Day Warranty. Please contact us with any questions! The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ HP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit includes the following options: 001- Power Amp/ DC
$
7003.64
Buy It Now
$120.00 Shipping
Condition: Used
Location: China
$
3950.00
Buy It Now
Free Shipping
Condition: Used
Location: San Diego, United States
HP/ Agilent 4284A 20Hz-1MHz Precision LCR Meter. Option 001/006 The 4284A/001/006 is in excellent physical and working condition. Includes NIST Calibration ... moreCertificate. The unit is offered with a 14 day right of return and a 30 Day Warranty. Please contact us with any questions! The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ HP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit includes the following options: 001- Power Amp/ DC
$
591.80
Buy It Now
$130.00 Shipping
Condition: New
Location: China
Up for sale is one NEW still in the box. Agilent U1733C 100kHz LCR meter. Never removed from the box. Lid was opened to take the picture. SOLD ASIS NO ... moreWARRANTY NO RETURN! PAYMENT—SHIPPING—RETURN STATEMENTS BASICS: I have no way to verify all functions. Any deficiencies known will be listed! Pictures are of actual item(s) for sale. PAYMENT: I accept Pay Pal(PayPal Preferred) Payment to be received within 3 days after auction ends! SHIPPING: I am currently only shipping to the United States! I normally ship on Tuesday and Thursday! I only ship by methods that provides tracking! Please keep in mind. I due refund shipping overages! As the Ebay calculator is sometimes wrong. Especially on large packages! I Do Not Ship to P.O. Boxes! EMAILS: I check emails regularly Monday thru Friday. Emails on the weekend may not occur depending on my schedule. So please be patient. As you might have to wait till Monday for an answer! RETURNS: If an item can be returned(see auction description) It must be in the same(original) condition that it was shipped in. Any tampering or breakage(not due to shipping accident) voids any return policy! Item will also be shipped back by original shipping method and packing! Return shipping is paid at the expense of the buyer! Good Luck. Thank you for looking and or bidding
$
1980.00
Buy It Now
$88.00 Shipping
Condition: Used
Location: China
Agilent/Keysight/HP 4263B LCR Meter. 100 Hz to 100 kHz, 1m ohm to 100M ohm with HP 16334A test fixture tweezers
$
975.00
Buy It Now
$140.00 Shipping
Condition: Used
Location: 罗湖区, China
We take our reputation seriously.
$
499.99
Buy It Now
$35.00 Shipping
Condition: Used
Location: China
What you see is what you get!
$
3600.00
Buy It Now
$160.00 Shipping
Condition: Used
Location: Hong Kong SAR China
HP/ Agilent 4284A 20Hz-1MHz Precision LCR Meter. Option 001/006 The 4284A/001/006 is in excellent physical and working condition. Includes NIST Calibration ... moreCertificate. The unit is offered with a 14 day right of return and a 30 Day Warranty. Please contact us with any questions! The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ HP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit includes the following options: 001- Power Amp/ DC
$
828.75
Buy It Now
$170.00 Shipping
Condition: Used
Location: 罗湖区, China
We take our reputation seriously.
$
74.78
Buy It Now
$5.00 Shipping
Condition: New
Location: China
Xp: equivalent shunt reactance. - Xs: equivalent series reactance. - Lp: inductor in parallel mode. - Ls: series inductor model. - ESR: equivalent series ... moreresistance. - Cp: capacitor in parallel mode.
$
417.25
Buy It Now
$25.00 Shipping
Condition: New – Open box
Location: China
Your request will be replied within 12 hours.
$
845.00
Buy It Now
$170.00 Shipping
Condition: Used
Location: China
$
4500.00
Buy It Now
$75.00 Shipping
Condition: Used
Location: Culver City, United States
This function ensures the reliability of PASS/FAIL testing with automatic handlers in production. The quick recovery system of the 4263B improves throughput. ... moreThe 4263B has five test frequencies that allow you to simulate testing under the correct conditions: 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz.
$
4300.00
Buy It Now
$200.00 Shipping
Condition: Used
Location: Japan
HP 4284A LCR METER DESCRIPTION The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ ... moreHP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit comes with the following options: 001- Power Amp/ DC Bias, 002- Bias Current Interface, All of our equipment has been tested. Additional calibration may be available upon request! ~Item sold with shown accessories. A power cord and manual on CD(when available)~ PAYMENT AND SHIPPING INFO Warranty I
$
3450.00
Buy It Now
$115.00 Shipping
Condition: Used
Location: Newbury Park, United States
HP/ Agilent 4284A 20Hz- 1MHz Precision LCR Meter with Options 001& 006- CALIBRATED! You are bidding on an HP/ Agilent 4284A 20Hz- 1MHz Precision LCR ... moreMeter with Options 001(High Power(20V. 200mA, 0-40V DC Bias) and 006(2m/4m Cable Length Operation) This unit was just calibrated in February 2014 and will come with a fresh certificate of calibration. The 4284A precision LCR meter is a cost-effective solution for component and material measurement. The wide 20 Hz to 1 MHz test frequency range and superior test-signal performance allow the Agilent 4284A to test components to the most commonly-used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent 4284A will meet all of your LCR meter test and measurement requirements. Features: Wide Range DC Current Biased Inductance Measurement-List sweep measurement capability You can view the specs for this unit here: This unit is in excellent condition. Has been fully tested and is guaranteed functional. It comes w/ a 5 day right of return should it not perform to your expectations. Please review pics and text carefully before bidding to verify accuracy of description. If you don't see it in the pictures, it is not included. Insurance is included in UPS shipping charges. I cannot ship internationally. I will accept payment for this item by company check. Cashiers check and wire transfer only. Feel free to send any questions regarding this item to: in fact I encourage you to do so) If you have zero feedback. Please before you bid to let me know that you are serious. Otherwise I may cancel your bid before the auction closes. It should be obvious that you should only bid if you are serious and do intend to complete the transaction. Any stated warranty will be voided if the unit is opened or if any calibration or lockout stickers have been tampered with or removed. Please note that shipping and insurance costs are
$
3839.04
Buy It Now
$200.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
339.50
Buy It Now
$120.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
669.00
Buy It Now
$140.00 Shipping
Condition: Used
Location: China
We will do our best and help you provide the solution. Price reduction is not acceptable.
$
652.28
Buy It Now
$140.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
625.00
Buy It Now
$100.00 Shipping
Condition: Used
Location: China
We will do our best and help you provide the solution.
$
357.74
Buy It Now
$20.00 Shipping
Condition: Used
Location: China
$
8899.00
Buy It Now
$400.00 Shipping
Condition: Used
Location: Taiwan
Spec:1 MHz - 3 GHz. I hope the item is able to comply with your test engineering and applications.
$
18800.00
Buy It Now
$150.00 Shipping
Condition: New – Open box
Location: China
※All faulty due to improper installation or improper use will NOT be covered by the warranty.
$
915.00
Buy It Now
$150.00 Shipping
Condition: Used
Location: China
$
3744.00
Buy It Now
$120.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
6950.00
Buy It Now
$135.00 Shipping
Condition: Used
Location: Culver City, United States
10 Adc with the Agilent 42841A. Not a problem. Agilent / HP 8720C 50MHz - 20GHz RF Vector Network Analyzer w/ Options 001 & 010. HP / Agilent 8566B 100 ... moreHz to 22 GHz Microwave Spectrum Analyzer w/ Cables.
$
49.99
Buy It Now
$20.00 Shipping
Condition: Used
Location: China
04261-77010 D1545 Mother Board for HP 4261A LCR Meter/ Working It is moved from a workig HP-4261A. What you see is what you get!
$
14.50
Buy It Now
$2.99 Shipping
Condition: New
Location: 福田区, China
1set 16mm 5pin XLR DIN Jack Female Socket to Kelvin Clip 4 Wires LCR Teset Cable Description Quantity: 1set Condition: Spec: 100% Brand new. Never used- ... more5 Pins DIN Socket connection for LCR Meter/ DC Low Ohmmeter- Wire configurations fit to the LCR meter/ DC Low Ohmmeter such as HP. Agilent, Anritsu.etc- One 12mm 5 Pin XLR DIN Jack Socket& 2 Kelvin Clips- Cable Color: Black- Length:0.7M. Part. No. 12-0031. International Buyers– Please Note: a) Import duties. Taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. b) Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. We combine shipping. Shipping Information All packages to United Stated will be shipped via ePacket/USPS with tracking number from China. Expect about 7-12 days for delivery. Tracking service: $ 2. Optional. Items will be shipped within 1 business days after payment received. Items ship from China and take about 10-15 business days(2-3 weeks) usually on the way. Via post air mail. Please contact us if you want other couriers such as UPS. DHL, Fedex, TNT, EMS etc. The shipping time depends on the efficiency of your local post office and customs. If you do not receive item within 30 days(4 weeks) Please contact me. The following is the shipping time reference for some countries. USA/Canada around 10 business days Western Europe(excluding France. Spain and Italy) around 10 business days France. Spain around 12 business days Italy around 21 business days South America around 28 business days We reserve the right to sell this items to some countries since some countries imposed complex customs regulation. Please check with us in advance. Payment Information Accept only Paypal payment. Payment must be made within 3 days after purchased. Unpaid will be reported. Return Policy Must return within 14 days after received the items. Returned item has to be in it's original condition. Buyer must pay for return
$
1800.00
Buy It Now
$350.00 Shipping
Condition: Used
Location: Japan
Agilent(HP) / 4263B. ・Discoloration, scratches, deformation, etc. of the exterior.
$
64.99
Buy It Now
$25.00 Shipping
Condition: Used
Location: China
04261-77005 D1614 PCB for HP 4261A LCR Meter/ Working It is moved from a workig HP-4261A. What you see is what you get!
$
3199.00
Buy It Now
$249.00 Shipping
Condition: Used
Location: Israel
Questions? Call us: 1-877-328-9236. HP 4284A Precision LCR Impedance Meter 20Hz-1MHz HP-IB Interface Options 001 006. Manufacturer: Hewlett Packard HP ... moreModel: 4284A Condition: Used Price: The photos show the exact item(s) the buyer will receive. Manufacturer: Hewlett Packard HP Condition: Used. Comes in non-original packaging. This meter is in Fair-to-Good cosmetic condition aside from several heavy dents/dings on the metal panels. There are also scuffs/scrapes and residues from old adhesive labels. Notes: This meter is in Good working condition. Using our own cables and samples(not included) for a quick test. We were able to measure an inductor, capacitor, and resistor as well as a short. The indications came back close to what we expected. We are not able to guarantee calibration will be within specification. No other testing was done. No manuals, cords/cables, or additional items are included if not listed or shown. Included: 1) HP 4284A Precision LCR Meter, Specifications: Manufacturer: Hewlett Packard, Model: 4284A, Precision LCR Meter, With HP-IB interface, Frequency range: 20Hz to 1MHz, for wide-range DC current biased measurement, 0.05% basic accuracy rating, 40A DC support when used with 42841A Bias Current Source(not included) Installed options: 001: Power Amp/DC Bias, 006: 2m/4m cable length operation, SKU: O12D012 For questions regarding this item. Please reference the SKU to help us better serve you. Questions? Give us a call. 877) 328-9236 or(512) 933-0081 Monday to Friday 8:30 am- 5:30 pm CST. Se habla espanol! DougDeals is an ISO 14001 and OHSAS 18001 registered company. DougDeals Terms and Conditions DougDeals Terms of Use. By bidding. Purchasing via Buy-It-Now or submitting a Best Offer you agree to the DougDeals terms of use located at: Payment. Paypal Orders are shipped to the confirmed PayPal address. DougDeals accepts PayPal from select countries. Visa. Mastercard, Discover, American Express Orders are shipped to the card holder’s billing address. A signed is required for order
$
4950.00
Buy It Now
$115.00 Shipping
Condition: Used
Location: Newbury Park, United States
HP/ Agilent 4284A 20Hz- 1MHz Precision LCR Meter with Options 001& 006- CALIBRATED! You are bidding on an HP/ Agilent 4284A 20Hz- 1MHz Precision LCR ... moreMeter with Options 001(High Power(20V. 200mA, 0-40V DC Bias) and 006(2m/4m Cable Length Operation) This unit was just calibrated in February 2014 and will come with a fresh certificate of calibration. The 4284A precision LCR meter is a cost-effective solution for component and material measurement. The wide 20 Hz to 1 MHz test frequency range and superior test-signal performance allow the Agilent 4284A to test components to the most commonly-used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent 4284A will meet all of your LCR meter test and measurement requirements. Features: Wide Range DC Current Biased Inductance Measurement-List sweep measurement capability You can view the specs for this unit here: This unit is in excellent condition. Has been fully tested and is guaranteed functional. It comes w/ a 5 day right of return should it not perform to your expectations. Please review pics and text carefully before bidding to verify accuracy of description. If you don't see it in the pictures, it is not included. Insurance is included in UPS shipping charges. I cannot ship internationally. I will accept payment for this item by company check. Cashiers check and wire transfer only. Feel free to send any questions regarding this item to: in fact I encourage you to do so) If you have zero feedback. Please before you bid to let me know that you are serious. Otherwise I may cancel your bid before the auction closes. It should be obvious that you should only bid if you are serious and do intend to complete the transaction. Any stated warranty will be voided if the unit is opened or if any calibration or lockout stickers have been tampered with or removed. Please note that shipping and insurance costs are
$
49.99
Buy It Now
$25.00 Shipping
Condition: Used
Location: China
04261-77008 A1622 PCB for HP 4261A LCR Meter/ Working It is moved from a workig HP-4261A. What you see is what you get!
$
3600.00
Buy It Now
$200.00 Shipping
Condition: Used
Location: China
HP/ Agilent 4284A 20Hz-1MHz Precision LCR Meter. Option 001/006 The 4284A/001/006 is in excellent physical and working condition. Includes NIST Calibration ... moreCertificate. The unit is offered with a 14 day right of return and a 30 Day Warranty. Please contact us with any questions! The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ HP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit includes the following options: 001- Power Amp/ DC
$
575.00
Buy It Now
$30.00 Shipping
Condition: Used
Location: China
Used and working condition.
$
64.99
Buy It Now
$25.00 Shipping
Condition: Used
Location: China
04261-77006 F1946 PCB for HP 4261A LCR Meter/ Working It is moved from a workig HP-4261A. What you see is what you get!
$
347.00
Buy It Now
$20.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
3182.50
Buy It Now
$189.60 Shipping
Condition: Used
Location: Cupertino, United States
Tested: Good.
$
7990.00
Buy It Now
$135.00 Shipping
Condition: Used
Location: Culver City, United States
Not a problem. If you don't see it in the pictures, it is not included. 10 Adc with the Agilent 42841A.
$
3605.50
Buy It Now
$130.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
3570.00
Buy It Now
$130.00 Shipping
Condition: Used
Location: China
We will do our best and help you provide the solution.
$
1842.40
Buy It Now
$160.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
94.99
Buy It Now
$25.00 Shipping
Condition: Used
Location: China
04261-77103 B1622 PCB for HP 4261A LCR Meter/ Working It is moved from a workig HP-4261A. What you see is what you get!
$
3300.00
Buy It Now
$300.00 Shipping
Condition: Used
Location: Japan
HP/ Agilent 4284A 20Hz-1MHz Precision LCR Meter. Option 001/006 The 4284A/001/006 is in excellent physical and working condition. Includes NIST Calibration ... moreCertificate. The unit is offered with a 14 day right of return and a 30 Day Warranty. Please contact us with any questions! The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ HP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit includes the following options: 001- Power Amp/ DC
$
7020.00
Buy It Now
$160.00 Shipping
Condition: New – Open box
Location: 罗湖区, China
We take our reputation seriously.
$
1900.00
Buy It Now
$350.00 Shipping
Condition: Used
Location: South Korea
Agilent 4263B LCR Meter. 100 Hz to 100 kHz, 1m ohm to 100M ohm. In excellent condition. Works fine. 30 Day Right to Return. Shipping: Domestic: $20. FedEx ... moreGround(including insurance) shipment within the United States. International: FedEx is our primary carrier. Charges will be calculated after the auction. Please include a contact phone number for shipping purposes. For shipping quotes please email. You may also use your own shipping account(UPS or FedEx or DHL) Please email your account number and the type of shipping service. Items will usually ship the same day payment clears. We will attempt to combine shipping wherever possible. Items is available for local pickup. However an appointment is required. Payment: Domestic: Paypal. Wire Transfer, Check, Credit Card(Visa/MC only) All transaction must clear before item ship. Unsecured funds must clear prior to shipment. International: Paypal or Wire Transfer only(US dollar only) Duties Taxes are the buyer's responsibility. No credit card purchases are accepted. Sales Tax: Charged to all California Purchases unless a valid tax exemption certificate is provided. Payment must be received within 7 days. Warranty: Warranted returns will be replaced or repaired. A refund will only be issued if the item cannot be replaced or repaired. This privilege does not cover items purchased in error. Damaged by customer misuse. Sales Listed"AS-IS" Items that are sold AS-IS are not covered under any warranty; express or implied. We do not accept returns on items sold AS-IS. NO EXCEPTIONS. Sales Listed"30 Day Right to Return" The buyer has 30 days in which to check the functionality of their purchase. If a problem is discovered. The buyer must notify us within the 30 day period. Defective items will be replaced or repaired. A refund will only be issued if the item cannot be replaced or repaired. Warranty starts the day item is shipped. Terms and Conditions: Your bid is a contract. Once you have placed a bid. You have entered a legally binding contract to purch
$
956.60
Buy It Now
$150.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
990.00
Buy It Now
$120.00 Shipping
Condition: Used
Location: China
$
499.99
Buy It Now
$35.00 Shipping
Condition: Used
Location: China
What you see is what you get!
$
3600.00
Buy It Now
$200.00 Shipping
Condition: Used
Location: China
HP/ Agilent 4284A 20Hz-1MHz Precision LCR Meter. Option 001/006 The 4284A/001/006 is in excellent physical and working condition. Includes NIST Calibration ... moreCertificate. The unit is offered with a 14 day right of return and a 30 Day Warranty. Please contact us with any questions! The Agilent/ HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent/ HP 4284A Meter has a wide frequency range and superior test signal performance. Which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent/ HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements. Features and Specifications of the Agilent/ HP 4284A LCR Meter include: 20 Hz to 1 MHz. With over 8,600 test frequencies 0.05% basic accuracy. 6-digit resolution Constant V or I test signal level List sweep measurement capability Parameters Measured: |Z |-q. |Y |-q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and% deviation Measurement Circuit Modes: Series and parallel Ranging: Auto and manual Trigger: Internal. External, manual, and bus(HP-IB) Delay Time: 0 to 60.000s in 1 ms steps Measurement Terminals: Four-terminal pair Test Cable Length: Standard: 0 and 1 m Integration Time: Short. Medium, and long Averaging: 1 to 256. Programmable Test Signal: 20 Hz to 1 MHz. 8610 selectable frequencies Test Signal Modes Normal: Programs selected voltage or current at the measurement terminals open or shorted. Respectively, and not at the device under test. Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance. Test Signal Levels(rms) Normal: 5mV to 2V. 50µA to 20mA Constant: 10mV to 1V. 100µA to 10mA DC Bias: 0V. 1.5V and 2V This unit includes the following options: 001- Power Amp/ DC
$
3690.00
Buy It Now
$330.00 Shipping
Condition: Used
Location: South Korea
$
973.00
Buy It Now
$120.00 Shipping
Condition: Used
Location: China
Your request will be replied within 12 hours.
$
420.00
Buy It Now
$25.00 Shipping
Condition: New – Open box
Location: China
We will do our best and help you provide the solution.
$
975.00
Buy It Now
$120.00 Shipping
Condition: Used
Location: 罗湖区, China
We take our reputation seriously.
1 2 3 4 5
 In