Order by:
Available to:
This site contains affiliate links for which I may be compensated
|
Buy It Now
$6.88 Shipping Condition: New Location: China Various of crank s(RPM,Frequency, Oil Pressure) can be chosen. Generator current A. Generator Frequency Hz. Generator active power KW. 1 switch value ... moreinput, and each can be set as max 20 functions. The waterof can reach IP54.
Buy It Now
$3.00 Shipping Condition: New Location: China DC92DR MK2: Based on DC92D MK2, it adds RS485 port. Genset working plan can be set as per week or month. - DC90D MK2: used for single machine automation. ... moreStart/Stop through remote start signal. - Indicator and number display through UI surface.
Buy It Now
Free Shipping Condition: New Location: China
Buy It Now
$3.99 Shipping Condition: New Location: China DC42MCR: Based on DC42MR: Change the speed sensor (MPU) detection to CAN communication interface, and adapt to more than 40 kinds of engines. - DC42MR: ... moreUsed for single machine automation. Start/Stop through remote start signal.
Buy It Now
$3.00 Shipping Condition: New Location: China DC42MCR: Based on DC42MR: Change the speed sensor (MPU) detection to CAN communication interface, and adapt to more than 40 kinds of engines. - DC42MR: ... moreUsed for single machine automation. Start/Stop through remote start signal.
Buy It Now
$17.80 Shipping Condition: New Location: Osceola, United States KUBOTA ONAN. ONAN GENERATOR K SERIES. What I have is mostly for the K series genset made by/for Onan in the 1990s. NUMBERS WHEN INQUIRING ABOUT OTHER ... morePARTS.
Buy It Now
$3.00 Shipping Condition: New Location: China DC72DR: Add RS485 interface on the basis of DC72D. - Adopting silica gel panel, effective waterproof, oil-proof, UV-proof, good operation feeling and ... morelong service life;. - Function and status display of input and output ports are clear at a glance;.
Buy It Now
$3.00 Shipping Condition: New Location: China Genset working plan can be set as per week or month. DC50CR-G4G: Used for single machine automation. - Generator Power Factor COS φ. - Generator active ... morepower KW. - Generator 3 phase current A. - Generator Frequency Hz.
Buy It Now
Free Shipping Condition: New Location: China
Buy It Now
Free Shipping Condition: New Location: Ljubljana, Slovenia • Rectifier fail output. The unit has overload and short circuit protections. They do not need disconnection during cranking. The high temperature protection ... moreof the unit reduces the output current in case of overheating.
Buy It Now
$3.99 Shipping Condition: New Location: China Serial Number: ADC120. - 1 x Set of Electric Actuator. - Function: speed actuator. - Application: diesel generator. Usually it cost about 35USD-50USD. ... more- Working Current: 2A.
Buy It Now
Free Shipping Condition: New Location: China With mains electricity monitoring and AMF functions;. Speed signals derive from ignition coil primary (diode need to be in series);. Three crank disconnect ... moreconditions can be optional (generator frequency, speed, and speed + gen frequency);.
Buy It Now
Free Shipping Condition: New Location: China DC40D MK3: used for single machine automation. Start/Stop through remote start signal. DC40DR MK3: Based on DC40D, it adds Rs485 port and CAN port. DC42DR ... moreMK3: Based on DC42D, it adds Rs485 port and CAN port.
Buy It Now
$13.99 Shipping Condition: New Location: China Various of crank conditions(RPM,Frequency, Oil Pressure) can be chosen. Generator current A. Generator Frequency Hz. Generator active power KW. 1 switch ... morevalue input, and each can be set as max 20 functions.
Buy It Now
$3.00 Shipping Condition: New Location: China Genset working plan can be set as per week or month. DC50CR-G4G: Used for single machine automation. - With RS485 communication port, can achieve "Three ... moreRemote" functions via MODBUS protocol. - Standard CAN communication port, built-in J1939 protocol, has matched more than 40 kinds of engines.
Buy It Now
$6.00 Shipping Condition: New Location: China DC60DR MK2: Based on DC60D MK2, it adds RS485 port. - DC60D MK2: used for single machine automation. Start/Stop through remote start signal. - With RS485 ... morecommunication port (optional), it can achieve "Three Remote" functions via MODBUS protocol.
Buy It Now
$8.00 Shipping Condition: New Location: China Input and output port status display;. Generator power factor COSφ;. The generator accumulates electrical energy Kwh;. Generator active power KW;. Generator ... moreapparent power KVA;. Generator reactive power KVar;.
Buy It Now
$3.00 Shipping Condition: New Location: China Its compact, simple wiring, high reliability, and can be widely used in all types of generator automation systems. Conditions of crank disconnect can ... morebe selected. (magnetic pickup, oil pressure, generator);.
Buy It Now
$3.99 Shipping Condition: New Location: China Genset working plan can be set as per week or month. DC50CR-G4G: Used for single machine automation. - With RS485 communication port, can achieve "Three ... moreRemote" functions via MODBUS protocol. - Standard CAN communication port, built-in J1939 protocol, has matched more than 40 kinds of engines.
Buy It Now
$16.00 Shipping Condition: New Location: China Ø Multiple crank disconnect conditions (speed sensor, oil pressure, generator frequency) are optional. Ø Equipped with CANBUS port and can communicate ... morewith J1939 genset. In one word,JEENDA aims to provide one-stop service for your generator spare parts demand.
Buy It Now
Free Shipping Condition: New Location: United States 2x Surge Suppressor. RSK6001 Diode Rectifier Kits For Stamford Generator Genset Spare Parts. The RSK6001 Diode Kit is used on generators ends. RSK6001 ... moreis designed for generator. RSK1001 used for the generator of BC series.
Buy It Now
Free Shipping Condition: New Location: China The average load rate, by calculating the load rate, detect genset load operation, avoid overload operation. Alternator Input Range. Alternator Frequency. ... moreSpeed Sensor Frequency. Power Consumption. Big screen (240 128) LCD display, on a page can browse all the data, avoid frequent page breaks.
Buy It Now
$5.00 Shipping Condition: New Location: China DC92DR MK2: Based on DC92D MK2, it adds RS485 port. Genset working plan can be set as per week or month. - DC90D MK2: used for single machine automation. ... moreStart/Stop through remote start signal. - Indicator and number display through UI surface.
Buy It Now
$14.62 Shipping Condition: New – Open box Location: Osceola, United States 541-0121 ONAN GRILL MOUNTING KIT FOR AN L634 L423 SERIES GENSET. ONAN FAN GUARD OR GRILL.
Buy It Now
Free Shipping Condition: New Location: China NEW Universal General 20A Automatic Voltage Regulator GAVR-20A Genset Generator Available: The GAVR 20A fit for Gensets/Generator/Alternator. Application: ... moreAVR M16FA655A is provided with internal circuits in order toreduce the excitation. When running at low speed, in order toavoid damages to the excitation devices system of thegenerator(i.e. to the regulator, to exciter field, to rotatingrectifier, main rotor) The potentiometer“P2/FREQ” fixesthe corner-frequency, that is the frequency at which thatprotection becomes effective. Below that particularfrequency the voltage of the generator reduces further withspeed reduction(voltage reduction is twice the reduction inspeed) 1) M16FA650A DC30V Supply 170-270V DC8A Fit For M6B 160-200& M7B 160-200 2) M16FA655A DC30V Supply 170-270V DC5A Fit For M8B 160-200& MJB 160-225 3) M40FA610A DC30V Supply 170-270V DC8A Fit For M7B 315-400 4) M40FA640A DC80V Supply 150-278V DC8A Fit For M8B 250-500 5) M40FA644A DC30V Supply 150-278V DC8A Fit For MJB 225-500 Note: It is not genuine MARELLI M16FA655A.Just replacement.Works great. Shipping Shipping by FedEx/DHL/TNT service to USA need 3-4 business days. Shipping by FedEx/DHL/TNT service to other countries.Need 3-6 business days Reture and Refund Policy After receiving the item.Contact US within 30 days. Refund will be given as Money back or item exchange(buyer's choice) Return shipping:Buyer pays return shipping. Attention Please If you have any problems or need.Please don't hesitate to contact me first.We will answer you within 24 hours Due to the time differences all over the world. My mail:kevin@at)gmail.com. Phone:0086 158 5777 6935. MSN:kevin0226@msn.cn. InkFrog Analytics.
Buy It Now
$5.00 Shipping Condition: New Location: China DC80D MK II: used for single machine automation. Start/Stop through remote start signal. DC80DR MK II: Based on DC80D MK II, it adds RS485 port. 1 phase ... more2 wire: 20VAC-276VAC(ph-N). 2 phase 3 wire: 20VAC-276VAC(ph-N).
Buy It Now
Free Shipping Condition: New Location: China Monitor Interface:RS485. Programmable Interface:LINK/RS485. Display:LCD(128 64). Switch Over Priority:√. Applicable Switch Type:All types.
Buy It Now
$8.00 Shipping Condition: New Location: Rowland Heights, United States Description: Brand New ESD5500E Series Speed Governor Item Specifics: ●ESD5500E series speed governor is high cost effective,the best quality,large stock,lower ... moreprice,perfectly electric speed governor. ●Widely used to all kinds of generator together with ADC120 12V ,high performance and perfectly realize electronic speed governor. Color: As shown in picture Package Included: 1x ESD5500E speed controller 1x MSP6729 Magnetic Speed Sensor 1x ADC120 actuator Speed Sensor MSP6729 Specifications: Inductance:142MH+25% Resistance:300 Ohms Maximum Thread Size: 3/8-24UNF-2A Proximity to Gear Teeth:0.025-0.035in.(0.64-0.89mm.) Temperature Range:-55℃ to 105℃ IDLE Ouput:1.5 volts AC minimum Max Output:30 volts AC ADC120-12 Actuator SPECIFICATIONS PERFORMANCE: Available Torque Max1.0Lb-ft(1.4Nm) Maximum.
Buy It Now
$10.60 Shipping Condition: New – Open box Location: Osceola, United States KUBOTA ONAN 185-4460 BRAKE ASSEMBLY for "K" SERIES GENERATOR NOS. What I have is mostly for the K series genset made by/for Onan in the 1990s. NUMBERS ... moreWHEN INQUIRING ABOUT OTHER PARTS.
Buy It Now
$10.60 Shipping Condition: New Location: Osceola, United States ONAN GENERATOR K SERIES. What I have is mostly for the K series genset made by/for Onan in the 1990s. NUMBERS WHEN INQUIRING ABOUT OTHER PARTS.
Buy It Now
$10.60 Shipping Condition: New Location: Osceola, United States KUBOTA ONAN. 185-3542 ONAN. ONAN GENERATOR K SERIES. What I have is mostly for the K series genset made by/for Onan in the 1990s. NUMBERS WHEN INQUIRING ... moreABOUT OTHER PARTS. 185-3542 CRANKCASE COVER KUBOTA.
Buy It Now
$5.00 Shipping Condition: New Location: China DC92DR MK2: Based on DC92D MK2, it adds RS485 port. Genset working plan can be set as per week or month. - Various of crank conditions (RPM, Frequency, ... moreOil Pressure) can be chosen. - Indicator and number display through UI surface.
Buy It Now
Free Shipping Condition: New Location: China By placing your bid. You are agree to follow our store policy below: ●All purchased are final, will replace defective product only. ●Return package must ... morebe in the original packaging, everything must be in new condition.Missing part’s or anything in original contact will not qualify for any refund. ●Unless marked in the auction, all product follow our 2 months warranty policy. ●Defective item can be exchanged within 7 days of receipt.Please send us some photoes as evidence. ●Within warranty period, all exchanges due to defects are free(Buyer is responsible for shipping charges) ●Shipping and handling fees are NOT refundable in any case. ●Custom duty is responsible by buyer. ●Replacement and refunds will not be processed until the return item received. ●Customer is responsible for correct address and received of package. Customer is responsible to all shipping if return package due to customer unable to received the package. ●Please do not ask us to reduce the price and shipping and handling fee of the item after you have won the auction. ●We are not responsible for wrong or undeliverable address, customer responsible undeliverable Express package return fee and re shipping fee.A valid phone number can make the delivery process more quickly and more safely. Description: External Generator Actuator ADC120-S24 1.Electronic Actuator ADC120-24 2.Engine Actuator ADC120-24 3.Genset Actuator ADC120-24 4.electronic damper actuator ADC120 Series· Rotary output linear torque proportional servo. Small. Low cost, low friction model. 1.0 lb-ft of torque. 25° rotation, Suitable for rotary or small inline fuel pumps of small carburetors. Ideal for fuel systems on engines up to 150 HP. Note: Ship many country! Please inquire us for the actual freight to your location. Post Code is required! A phone number is required for the smoothly delivery of your goods! Combined purchase is welcomed! We accept 1.UK Bank transfer 2.PayPal www.paypal.com 3. Moneybookers www.moneybookers.com 3.the customers want use a Credit Card or
Buy It Now
Free Shipping Condition: New Location: China The cloud monitoring communication module is a 4G full Netcom wireless network communication protocol conversion module, which can realize the connection ... moreof the generator set (with serial communication interface) to the Internet.
Buy It Now
Free Shipping Condition: New Location: Ljubljana, Slovenia The Datakom DKG-119 is a comprehensive generator control unit designed to start and stop the generating set both manually and remotely. The manual control ... moreis made using the pushbuttons on the front panel. The remote control is made via the REMOTE START input signal. In AUTOMATIC position. DKG-119 monitors the REMOTE START signal and controls the automatic starting, stopping and load transfer of the generating set. Once the generator is running, it monitors internal protections and external fault inputs. If a fault condition occurs, the unit shuts down the engine automatically and indicates the failure source with the corresponding red led lamp and text. The operation of the unit is controlled with front panel pushbuttons. The RUN. AUTO and STOP pushbuttons select the operating mode. Other buttons select the display parameter scroll, alarm mute and lamp test functions. The DKG-119 provides a comprehensive set of digitally adjustable timers, threshold levels, input and output configurations and operating sequences. The unauthorized access to program parameters is prevented by a 3 level password protection. All programs may be modified via front panel pushbuttons, and do not require an external unit. The fault conditions are considered in 3 categories as Warnings, Loaddumps and Shutdown Alarms. Measured values have separate programmable limits for warning and shutdown conditions. The unit is able to send SMS messages in fault conditions. Last 100 faults are stored in the event log file. The event log includes a comprehensive list of measured genset parameters at the time that the fault has occurred. The unit offers the magnetic pickup input as standard for engine rpm measurement. The service request warning turns on at the expiration of either engine hours or time limits. It is possible to monitor and control the operation of the system locally or remotely with the WINDOWS based RAINBOW program(external adapter required) The unit supports MODBUS protocol enabling communication with PLCs and building management sy
Buy It Now
$3.99 Shipping Condition: New Location: China DC70DR: Add RS485 interface on the basis of DC70D;. - With RS485 interface, three remote functions can be realized by using the protocol for MODBUS; (Only ... morefor DC70DR and DC72DR). DC72DR: Add RS485 interface on the basis of DC72D.
Buy It Now
$8.00 Shipping Condition: New Location: China It is especially suitable for the automation system composed by mains and genset. Genset working plan can be set as per week or month. - Mains Frequency ... more(Only for DC52CR-G4G). DC50CR-G4G: Used for single machine automation.
Buy It Now
$3.00 Shipping Condition: New Location: China DC72DR: Add RS485 interface on the basis of DC72D. - With RS485 interface, three remote functions can be realized by using the protocol for MODBUS; (Only ... morefor DC70DR and DC72DR). DC70DR: Add RS485 interface on the basis of DC70D;.
Buy It Now
Free Shipping Condition: New Location: China It is an ideal option for ATS. Applicable for ATS of one neutral position, two neutral position and non-position. With standard LINK communication interface. ... moreSystem type can set as: Mains (1#) & Generator (2#), Generator (1#) & Mains (2#), Mains (1#) & Mains (2#), Generator (1#) & Generator (2#).
Buy It Now
$10.00 Shipping Condition: New Location: China Part No.:DC20D. DC20D is one Panel used for Diesel Engine or Generator. It is with the functions of Auto Star/Stop,Protection and Alarm indication.DC ... morePower and Running situation is indicated on the front panel.
Buy It Now
$3.99 Shipping Condition: New Location: China DC92DR MK2: Based on DC92D MK2, it adds RS485 port. - Various of crank conditions (RPM, Frequency, Oil Pressure) can be chosen. - Indicator and number ... moredisplay through UI surface. - DC90D MK2: used for single machine automation.
Buy It Now
$20.00 Shipping Condition: New Location: China Conditions of crank disconnect can be selected. (magnetic pickup, oil pressure, generator);. 132x64 LCD with backlight, optional language interface (Chinese, ... moreEnglish, Spanish and Russian), push-button operation;.
Buy It Now
$5.00 Shipping Condition: New Location: China Generator three-phase current A;. Input and output port status display;. Generator frequency Hz;. Generator power factor COSφ;. The generator accumulates ... moreelectrical energy Kwh;. Generator active power KW;.
Buy It Now
$20.00 Shipping Condition: New Location: China Conditions of crank disconnect can be selected. (magnetic pickup, oil pressure, generator);. 132x64 LCD with backlight, optional language interface (Chinese, ... moreEnglish, Spanish and Russian), push-button operation;.
Buy It Now
$3.00 Shipping Condition: New Location: China DC92DR MK2: Based on DC92D MK2, it adds RS485 port. - DC90DR MK2: Based on DC90D MK2, it adds RS485 port. - With RS485 communication port, can achieve ... more“Three Remote” functions via MODBUS protocol.
Buy It Now
$8.00 Shipping Condition: New Location: China Genset working plan can be set as per week or month. Adapt to 3P4W,1P2W,2P3W (120V/240V,50/60HZ). - Various of crank conditions (RPM, Frequency, Oil Pressure) ... morecan be chosen. - Generator 3 phase current A.
Buy It Now
$6.88 Shipping Condition: New Location: China Various of crank s(RPM,Frequency, Oil Pressure) can be chosen. Generator current A. Generator Frequency Hz. Generator active power KW. 1 switch value ... moreinput, and each can be set as max 20 functions. The waterof can reach IP54.
Buy It Now
Free Shipping Condition: New Location: China It is an ideal option for ATS. Applicable for ATS of one neutral position, two neutral position and non-position. With standard LINK communication interface. ... moreSystem type can set as: Mains (1#) & Generator (2#), Generator (1#) & Mains (2#), Mains (1#) & Mains (2#), Generator (1#) & Generator (2#).
Buy It Now
$5.00 Shipping Condition: New Location: China It can be widely used in power systems. - ATS520R: RS485 interface + ATS520;. - Automatic/manual switching. In manual mode, closing and opening can be ... moreachieved;. - 3.5"240 128 LCD display of high resolution.
Buy It Now
$5.00 Shipping Condition: New Location: China Mains frequency (only for DC52D-4G);. Input and output port status display;. A variety of starting conditions (speed, frequency and oil pressure) combination ... morecan be selected;. GPRS antenna interface: standard SMA interface (female), antenna is SMA interface (male).
Buy It Now
Free Shipping Condition: New Location: China
Buy It Now
Free Shipping Condition: New Location: China It is an ideal option for ATS. Applicable for ATS of one neutral position, two neutral position and non-position. With standard LINK communication interface. ... moreSystem type can set as: Mains (1#) & Generator (2#), Generator (1#) & Mains (2#), Mains (1#) & Mains (2#), Generator (1#) & Generator (2#).
Buy It Now
$10.60 Shipping Condition: New Location: Osceola, United States ONAN GENERATOR K SERIES. What I have is mostly for the K series genset made by/for Onan in the 1990s. NUMBERS WHEN INQUIRING ABOUT OTHER PARTS.
Buy It Now
$8.00 Shipping Condition: New Location: China Genset working plan can be set as per week or month. DC50CR-G4G: Used for single machine automation. - Generator Power Factor COS φ. - Generator active ... morepower KW. - Generator 3 phase current A. - Generator Frequency Hz.
Buy It Now
$8.00 Shipping Condition: New Location: China Product series: ADC120. - Function: speed actuator. - 1 x Set of Electric Actuator. - Application: diesel generator. Usually it cost about 35USD-50USD.
Buy It Now
$8.99 Shipping Condition: New Location: China Various of crank conditions(RPM,Frequency, Oil Pressure) can be chosen. Generator current A. Generator Frequency Hz. Generator active power KW. 1 switch ... morevalue input, and each can be set as max 20 functions.
Buy It Now
$6.00 Shipping Condition: New Location: China DC92DR MK2: Based on DC92D MK2, it adds RS485 port. - Dual core 32bit high performance single chip microcomputer. - Various of crank conditions (RPM, ... moreFrequency, Oil Pressure) can be chosen. - Indicator and number display through UI surface.
Buy It Now
$8.25 Shipping Condition: New Location: Minneapolis, United States P/N: 3S-9643 (PTFE Lip Seal). CAT Caterpillar. 924G 928HZ 930H 950F 950F II 960F 966F 966G II 966H 972G II 972H 980 980B 980C 980F 980F II 980G 980G II ... more980H 980K 980K HLG 980L 980M 980XE 982 982M 982XE 986H 986K 988 988B 988F 988F II 988G 988H 988K 988K XE 990 990 II 990H 990K 992 992B 992C 992D 992G 992K 993K 994 994D 994F 994H 994K.
Buy It Now
$14.90 Shipping Condition: New Location: China Conditions of crank disconnect can be selected. (magnetic pickup, oil pressure, generator);. 132x64 LCD with backlight, optional language interface (Chinese, ... moreEnglish, Spanish and Russian), push-button operation;.
Buy It Now
$20.00 Shipping Condition: New Location: China 1x Generator ADC120 Actuator. Connector ADC120 Supplied with Actuator. 1x MSP6729 Magnetic RPM Sensor. Lever ADC120 LE 1500-2. Actuator 4. Genset Actuator. ... moremotor operated valve actuator. External Actuator.
|
|
|