|
Order by:
Available to:
This site contains affiliate links for which I may be compensated
|
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO012. Length(ft. 100 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 4. Conductor Colors: Black. ... moreWhite, Red, Green. Nominal Jacket Thickness: 0.05 in. 1.27 mm) Voltage Rating: 600V. Nominal O.D. 0.86 in. 21.844 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 36. Weight(lbs/1000 ft) 664. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and cond
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO022. Length(ft. 10 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Ventura, United States ETL approved. SOOW stands for S = Service Cord, OO = Oil Resistant (both inside and outside insulation), W = Weather and Water Resistant. Internal conductors ... moreinsulated with colored coded flexible CPE insulation.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO021. Length(ft. 5 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made in
Buy It Now
Free Shipping Condition: New Location: Ventura, United States This SOOW cable is UL62 approved. SOOW stands for S = Service Cord, OO = Oil Resistant (both inside and outside insulation), W = Weather and Water Resistant.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO012. Length(ft. 100 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 4. Conductor Colors: Black. ... moreWhite, Red, Green. Nominal Jacket Thickness: 0.05 in. 1.27 mm) Voltage Rating: 600V. Nominal O.D. 0.86 in. 21.844 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 36. Weight(lbs/1000 ft) 664. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and cond
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO025. Length(ft. 25 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New – Open box Location: Talking Rock, United States Price is for 5 feet. May have dust from storage.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States Seoprene® 105– Black Features: Flexible and tough Seoprene jacket, 50°C to 105°C temperature extremes, Excellent abrasion. Ozone, sunlight, ... morechemical and oil resistance. Non-wicking lightweight polypropylene fillers, Water resistant with high dielectric insulation, Lightweight. Long lasting, easy to carry and easy to handle, Fully recyclable and non-hazardous for environmental landfill disposal, Color-coded conductors for easy identification. Applications: Special uses requiring flexibility and mechanical toughness. High environmental resistance and flame retardance, Push button remote controls. Motor control, stage equipment and lighting, industrial control and robotic systems, Outdoor applications and suitable and approved for submersion in water, Industry Approvals: Federal and Military use under Federal Spec. JC-580B. UL Listed SEOOW 600V to NEC Article 400, CSA certified STOOW or SJTOOW(TPE) 50°C to 105°C, MSHA approval for flame resistance for mining applications. ROHS Compliant,
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 75' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
$26.36 Shipping Condition: New – Open box Location: Pierre Part, United States TEMCo ID: SOO025. Length(ft. 25 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO023. Length(ft. 15 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Ventura, United States SOOW stands for S = Service Cord, OO = Oil Resistant (both inside and outside insulation), W = Weather and Water Resistant. Internal conductors insulated ... morewith colored coded flexible CPE insulation.
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 10' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO022. Length(ft. 10 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO027. Length(ft. 35 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 150' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO021. Length(ft. 5 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made in
Buy It Now
Free Shipping Condition: New Location: Waterford, United States 8 AWG 4 CONDUCTOR SOOW PORTABLE CABLE Features: ---Manufacturered with advanced synthetic rubber compounds ----40°C to 90°C temperature extremes ---Exceptional ... moreflexibility ---Excellent resistance to flame, deformation, ozone, oils, acids and chemicals ---Oil resistant insulation and jacket ---Abrasion resistant ---Flexible in cold temperatures Applications: ---Motor leads, portable lights, battery chargers, portable stage lights and portable machinery ---National Electric Code Article 400 applications Industry Approvals: ---MSHA approved for flame resistance in mining applications ---ROHS Compliant.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO023. Length(ft. 15 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Pittsburgh, United States This 9.5 feet long black rubber cord is suitable for outdoor and indoor use. Its flexible structure allows for easy installation and maneuverability. ... moreThe cord consists of multiple conductors made of high-quality copper material with a wire gauge of 6. It is cut by the foot, making it convenient for any length of use. With insulation material made of rubber, this cord is a durable and reliable option for all your electrical equipment and supplies needs. Its sheath color is black, and it belongs to the category of wire and cable conduit. Use it for all your business and industrial purposes without worrying about the condition of the cord.
Buy It Now
Free Shipping Condition: New Location: Canton, United States TEMCo ID: SOO023. Length(ft. 15 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 50' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO028. Length(ft. 40 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO021. Length(ft. 5 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made in
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 5' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO022. Length(ft. 10 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO028. Length(ft. 40 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO012. Length(ft. 100 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 4. Conductor Colors: Black. ... moreWhite, Red, Green. Nominal Jacket Thickness: 0.05 in. 1.27 mm) Voltage Rating: 600V. Nominal O.D. 0.86 in. 21.844 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 36. Weight(lbs/1000 ft) 664. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and cond
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO025. Length(ft. 25 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 25' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Burke, United States SOOW is a water and weather-resistant service electrical cable with an oil-resistant jacket and insulation. The cable exhibits premium flexibility and ... moreis resistant to chemicals, oil, water, sunlight, and air.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 40' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 100' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO024. Length(ft. 20 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 200' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO031. Length(ft. 75 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New Location: Waterford, United States 6 FT 8”inches 2/4 SOOW SO SOO SOW BLACK RUBBER CORD EXTENSION WIRE/CABLE
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Waterford, United States TEMCo ID: SOO031. Length(ft. 75 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 60' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New – Open box Location: Mattoon, United States 125' 6-4 SOOW BLACK RUBBER CORD/CABLE. GREAT FOR PROJECTS THAT YOU NEED A HEAVY DUTY WIRE, LIKE EXTENSION CORDS. THIS IS NEW RUBBER CORD. SPECS ON WIRE ... more6 GAUGE 4 CONDUCTOR - CONDUCTORS ARE BLACK, WHITE, RED & GREEN.
Buy It Now
Free Shipping Condition: New Location: Brooksville, United States These are unused cut-offs and the length is in feet and will be equal to the stated length or longer. If a label is on an item, the label must remain ... moreon the item in the condition it was sent.
Buy It Now
Free Shipping Condition: New Location: Toledo, United States So, a 2 wire cord has black and white only, a 3 wire cord has black, white, and green only, and a 4 wire cord has black, white, green and red only. No ... moreextra ground. Standards: Subject 62 CSA flexible cord C22.2-49 OSHA accepted MSHA approved.
Buy It Now
Free Shipping Condition: New Location: Mankato, United States SOOW is a water and weather-resistant service electrical cable with an oil-resistant jacket and insulation. The cable exhibits premium flexibility and ... moreis resistant to chemicals, oil, water, sunlight, and air.
|
|
6/4 SOOW SO Cord Approx. 95' 600V 50A Hubbell Twist & Lock Portable Power Cord
For sale is a 95' 6/4 SOOW 600V Poratble Power Cord with 50A Hubbell Twist and Lock Plugs. These are in very good used condition. There was no cuts or defects noticed in the cable. SALES TERMS: All products are purchased under an as-is condition with no warranties or guarantees of any kind. PAYMENT INFORMATION: We accept PAYPAL as payment. All items must be paid in full before they are shipped. SHIPPING INFORMATION: We ship within the United State and use all common carriers and truck freight. When requested we will combine multiple orders to reduce shipping costs. If possible. If you have a specific carrier you would like to use or have an account that you would like the shipping to be billed to, tell us and we will prepare your item for shipment for a small handling fee. RETURN POLICY: Our goal is to please our customers. We do our ... morebest to describe each item accurately. If an item arrives damaged or incorrectly described. We will work with you to resolve the situation. Any item damaged or incorrectly described must not be used by the buyer or altered after receipt or no refund will be granted. Any refund given will be less all shipping costs. If there is a problem, please email us.
|
|
6/4 SOOW SO Cord 29 ft Outdoor Indoor 600 V Flexible Wire cable
This cable is in very good condition. It was left over from moving some CNC Machines around in our shop. It may be a little dirty from sitting in the shop but otherwise in great shape. No cuts or breaks in any of the rubber. We have a lot of different lengths listed. If you buy multiples we will combined shipping to save you money. Email with any Questions.
|
|
6/4 soow so cord 20 ft portable outdoor indoor 600 volt flexible cable w/plug
Very nice piece of 6/4 copper rubber cord. SOOW. 600Volt, Rubber, this is a high quality piece of cable. 20ft+. 4 wire plug with kellum supports. Flat rate shipping to the lower US 48 states only of $16. RcmdId ViewItemDescV4,RlogId p4%60bo7%60jtb9%3Fuk.rp*a4%601gc%3E-149d90f62f1-0x10d-
|
|
|