Manual R3-S32 Nec National Electrical Code National Electrical Code National Electrical Code Book Code Nfpa Wiring Simplified Trygon Model Manual R3s33 Power Supply Instruction Manual R3-S45 Manual R3-S31 Manual R3s31 Nec 2008 Manual R3-S24 Electrical Handbook Nfpa 70 Research Laboratory Eico Assembly Instruction Manual National Electrical Code Handbook Nec 2005 Datapulse Model Electrical Reference Polarad Model Test Measurement Catalog Vtg Rockwell Manual R3s32 Oscilloscope Instruction Manual Electrical Wiring Instruction Manual R3-S32 Schematic Parts List Instruction Manual R3-S31 Integrated Circuits Ohm's Law Instruction Manual R3-S24 Manual On Cd Free Usa Shipping Instruction Maintenance Manual R3-S45 Half Rack Hewlett Packard Model Heathkit Assembly Manual Electrical Manual Heathkit Assembly Electrical Equipment Mcgraw Hill Instruction Manual R3s31 Operators Instruction Agilent Basic Electrical Home Repair Catalog Brochure Catalog Brochures Circuits Breakers Data Book Digital Piano Servicing Manual And Schematic Electrical Engine Electrical Supply Catalogue Fluke Ge Ge Fanuc Generating Operators Generating Operators Maintenance Manual R3s31 Generator Operations Ham Radio Hewlett Packard Hewlett Packard Hp Hitachi Hp Industrial Installation Operators Manual Instruction Manual Kawai Digital Piano Servicing Manual Klein Tools Maintenance Manual Manual Model Multimeter Nec Operations Maintenance Manual Operations Manual Operators And Servicing Manual Operators Maintenance Manual Operators Manual Operators Servicing Manual Operators Servicing Manual R3s33 Plotter Power Designing Model Pulse Generating Operators Maintenance Reference Book Service Manual Servicing Manual And Schematic Servicing Manual R3s24 Servicing Manual R3-S32 Signal Generating Signal Generator Technical Manual Test Equipment Tools Transistor Usa Shipping User Guide User Manual Volume 1 Vtg Booklet Catalog Brochures Vtg Ge General Electrical Catalog Vtg Ge General Electrical Manual Watthour House Electrical Watthour House Electrical Meters Power Supplies Instruction Manual R3-S45 Electrical Meters Ge General Electrical Operations Service Manual Electrical Code Books Servicing Manual Electrical Motor Series Power Supplies Instruction Manual R3-S45 Ge General Electrical Research Laboratory
 In 
 
Order by: 
Available to: 
Price: 
 - 
This site contains affiliate links for which I may be compensated
$
110.95
Buy It Now
Free Shipping
Condition: New
Location: Toledo, United States
Applications: Copper UF-B cable is generally used as a circuit to outside loads. It may be used underground, including direct burial. Multiple conductor ... moreUF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
29.63
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
14/2 UF-B x 45' Southwire Underground Feeder Electrical Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride (PVC). 1 x #14 AWG Non-Insulated ... more(Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70.
$
97.99
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). 2 x #10 AWG Solid Insulated Copper Conductors (Black and White).
$
207.90
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
40.99
Buy It Now
Free Shipping
Condition: New
Location: Hebron, United States
Type: Generator Interlock Kit. High Quality:the interlock kit is made of corrosion-resistant aluminum alloy, and has been treated with surface anodization, ... morewhich has better heat insulation, electrical insulation, so that you can use electricity safely.
$
528.95
Buy It Now
Free Shipping
Condition: New
Location: Toledo, United States
Applications: Copper UF-B cable is generally used as a circuit to outside loads. It may be used underground, including direct burial. Multiple conductor ... moreUF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
300.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
1 AWG Aluminum XHHW-2 Building Wire 600V. They may be used in wet or dry locations with conductor temperatures not exceeding 90°C and may be used in conduit ... moreand recognized raceways as specified in the National Electrical Code.
$
42.88
Buy It Now
Free Shipping
Condition: New
Location: Ventura, United States
Stay connected with the Windy Nation 16 Gauge 3 Conductor SJOOW cable. 16/3 SJOOW cable designed with pure copper conductors and ultra-flexible insulation ... morejacket, this cable is perfect for portable power needs.
$
700.00
Buy It Now
Free Shipping
Condition: New
Location: Albuquerque, United States
Cross-linked polyethylene insulation (XLPE). They may be used in wet or dry locations with conductor temperatures not exceeding 90°C and may be used in ... moreconduit and recognized raceways as specified in the National Electrical Code.
$
210.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
Aluminum XLP USE Direct Burial. - 8/2 UF wire Permitted for use underground, including direct burial in earth as feeder, or branch circuit cable where ... moreprovided with overcurrent protection. Aluminum URD Direct Burial.
$
43.85
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
1 x #14 AWG Non-Insulated (Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). 3 x #14 AWG Solid Insulated Copper Conductors (Black,Red, and White).
$
38.91
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
12/2 UF-B x 35' Southwire Underground Feeder Electrical Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride (PVC). 1 x #12 AWG Non-Insulated ... more(Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70.
$
37.69
Buy It Now
Free Shipping
Condition: New
Location: Hebron, United States
This model fits both Siemans or ITE 100 amp panels with this style main breaker. Fits: For Siemans or ITE 100 Amp Panels. Type: Generator Interlock Kit. ... moreYou will love it! 1 x Generator Interlock Kit (as pictures shown).
$
34.99
Buy It Now
Free Shipping
Condition: New
Location: China
Fits: For Challenger & Westinghouse & Siemans 200 Amp Panel. Type: Generator Interlock Kit. You will love it! 1 x Generator Interlock Kit (as pictures ... moreshown). Our generator lockout switches are made of heavy gauge aluminum alloy and be chamfered for a smooth surface.
$
44.99
Buy It Now
Free Shipping
Condition: New
Location: Hebron, United States
Murray. ITE, Arrow Hart or Siemens Generator Interlock clip This fits older 100 amp panels with this style main Kit Includes: Instruction. Labeling, drill ... morebit and interlock clip Please check the pictures to make sure it matches your panel Please follow all National Electric Codes when installing this interlock Breakers and panelbox not included. If you are looking for a different style please check our store or contact us.
$
170.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
Aluminum XLP USE Direct Burial. - 8/2 UF wire Permitted for use underground, including direct burial in earth as feeder, or branch circuit cable where ... moreprovided with overcurrent protection. Aluminum URD Direct Burial.
$
342.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential ... moreor agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
2250.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
Copper THHN THWN-2. 2/0 AWG Copper THHN THWN-2 Wire 600V. • THHN Applications are suitable for use in dry locations only at temperatures not to exceed ... more90°C. Bus Drop Cable. Copper XHHW-2 Wire. Lengths 50 Feet to 1000 Feet.
$
105.00
Buy It Now
Free Shipping
Condition: New
Location: New York, United States
Southwire Romex Brand SIMpull NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures ... morenot to exceed 90C (with ampacity limited to that for 60C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.
$
139.98
Buy It Now
Free Shipping
Condition: New
Location: Chicago, United States
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted ... morefor new construction or rewiring for 600-volt applications.
$
280.94
Buy It Now
Free Shipping
Condition: New
Location: Waterford, United States
TEMCo ID: SOO028. Length(ft. 40 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
$
109.97
Buy It Now
Free Shipping
Condition: New
Location: Spanish Fork, United States
SUPER VERSATILE: THHN / THWN insulated Copper wire may be used in conduit and table trays for services, feeders, and branch circuits. 600 VOLTS CAPACITY: ... moreHas the ability to handle up to 600 volts which covers most common appliances.
$
37.69
Buy It Now
Free Shipping
Condition: New
Location: Hebron, United States
For both Siemans or ITE 100 amp panels with this style main breaker. The National Electric Code Requires a Generator Interlock Device When Powering a ... moreBreaker Panel with a Generator. Failure to Install an Interlock Could Have Fatal Consequences to a Lineman or Utility Worker!
$
153.94
Buy It Now
Free Shipping
Condition: New
Location: Waterford, United States
TEMCo ID: SOO051. Length(ft. 50 ft. Color: Black. Gauge: 8 AWG. No. of Strands per Conductor: 65. Number of Conductors: 4. Conductor Colors: Black. White, ... moreRed, Green. Voltage Rating: 600V. Nominal O.D. 0.76 in. 19.304 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 28. Weight(lbs/1000 ft) 506. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Ma
$
42.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
The NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft) copper. Stranded conductors ... moreare compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed.
$
62.94
Buy It Now
Free Shipping
Condition: New
Location: Chicago, United States
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted ... morefor new construction or rewiring for 600-volt applications.
$
142.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential ... moreor agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
57.94
Buy It Now
Free Shipping
Condition: New
Location: Waterford, United States
TEMCo ID: SOO022. Length(ft. 10 ft. Color: Black. Gauge: 6 AWG. No. of Strands per Conductor: 133. Number of Conductors: 3. Conductor Colors: Black. White, ... moreGreen. Voltage Rating: 600V. Nominal O.D. 0.79 in. 20.066 mm) Insulation Thickness: 0.05 in. 1.27 mm) Current(amps) per conductor: 45. Weight(lbs/1000 ft) 562. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: MSHA. ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant. Proudly Made i
$
290.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
Jumper Cable. Alpha Wire. Bus Drop Cable. - 8/3 NM-B Wire is primarily used in residential wiring as branch circuits for outlets, switches, and other ... moreloads. - Compressed Stranded Conductor. Aluminum URD Cable.
$
13.02
Buy It Now
$21.69 Shipping
Condition: Used
Location: Middlebury, United States
MPN: 9001KY3. Prefer to pick it up yourself?. Will there be a dock or forklift. Weight (lbs, oz): 5. Size: Length: 14 in. Width: 6 in. Height: 8 in. Need ... moreit urgently?.
$
62.93
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
270.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
Jumper Cable. Alpha Wire. Bus Drop Cable. - 6/2 NM-B Wire is primarily used in residential wiring as branch circuits for outlets, switches, and other ... moreloads. - Compressed Stranded Conductor. Aluminum URD Cable.
$
2.25
Buy It Now
$30.00 Shipping
Condition: New
Location: Carlyle, United States
SEU can also be used in certain branch circuits as permitted by the 2005 National Electric Code. Jumper Cable. Bus Drop Cable. Aluminum Service Drop Cable. ... moreAluminum URD Cable. Copper SER. Copper XHHW.
$
229.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential ... moreor agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
17.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential ... moreor agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
259.94
Buy It Now
Free Shipping
Condition: New
Location: Waterford, United States
TEMCo ID: SOO262. Length: 100 ft. Color: Black. Gauge: 10 AWG. No. of Strands per Conductor: 105. Number of Conductors: 5. Conductor Colors: Black. White, ... moreGreen, Red, Orange. Voltage Rating: 600V. Nominal O.D. 0.77 in. 19.558 mm) Insulation Thickness: 0.045 in. 1.143 mm) Current(amps) per conductor: 20. Weight(lbs/1000 ft) 425. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: UL. CSA, MSHA, ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil re
$
25.00
Buy It Now
$11.70 Shipping
Condition: Used
Location: Dallas, United States
Breaker Hub specializes in the sales, purchasing, removal, rental, dismantling.
$
169.44
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
513.95
Buy It Now
Free Shipping
Condition: New
Location: Toledo, United States
Applications: Copper UF-B cable is generally used as a circuit to outside loads. It may be used underground, including direct burial. Multiple conductor ... moreUF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
240.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
SEU can also be used in certain branch circuits as permitted by the National Electric Code. Jumper Cable. Alpha Wire. Bus Drop Cable. Copper XHHW-2 Wire. ... moreFire Alarm Cable. Aluminum Service Drop Cable.
$
155.16
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
47.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential ... moreor agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
42.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Mattoon, United States
UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential ... moreor agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
35.69
Buy It Now
$1.99 Shipping
Condition: New
Location: Hebron, United States
This model fits both Siemans or ITE 100 amp panels with this style main breaker. • Siemans or ITE panels. This Interlock Kit mounts toSiemans or ITE electrical ... morepanels and requires Type: Generator Interlock Kit.
$
182.44
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
45.00
Buy It Now
$4.75 Shipping
Condition: New
Location: Huntington Station, United States
PKG IN ORIGINAL MILITARY CONTRACT # SP0414-02-M-2465.
$
41.99
Buy It Now
Free Shipping
Condition: New
Location: Hebron, United States
Type: Generator Interlock Kit. High Quality:the interlock kit is made of corrosion-resistant aluminum alloy, and has been treated with surface anodization, ... morewhich has better heat insulation, electrical insulation, so that you can use electricity safely.
$
582.95
Buy It Now
Free Shipping
Condition: New
Location: Toledo, United States
Applications: Copper UF-B cable is generally used as a circuit to outside loads. It may be used underground, including direct burial. Multiple conductor ... moreUF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
$
156.86
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). 3 x #10 AWG Solid Insulated Copper Conductors (Black,Red, and White).
$
28.94
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
14/3 UF-B x 35' Southwire Underground Feeder Electrical Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride (PVC). 1 x #14 AWG Non-Insulated ... more(Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70.
$
297.94
Buy It Now
Free Shipping
Condition: New
Location: Waterford, United States
TEMCo ID: SOO072. Length: 35 ft. Color: Black. Gauge: 10 AWG. No. of Strands per Conductor: 105. Number of Conductors: 4. Conductor Colors: Black. White, ... moreRed, Green. Voltage Rating: 600V. Nominal O.D. 0.715 in. 18.161 mm) Insulation Thickness: 0.045 in. 1.143 mm) Current(amps) per conductor: 20. Weight(lbs/1000 ft) 371. Temperature Rating: 40°C to +90°C. Conductor: Fully annealed stranded bare copper per ASTM B-174. Class K. Insulation: Ethylene Propylene Rubber(EPR) Agency Approvals: UL. CSA, MSHA, ROHS Compliant. Applications: For use as portable electrical power and portable control cable. Not for direct burial applications. Can be used for ground test or motor leads. Also can provide heavy-duty service for industrial tools. Portable lights, battery chargers and equipment exposed to oils, solvents, flame. Manufactured with advanced synthetic rubber compounds. 40°C to 90°C temperature extremes. Exceptional flexibility. Excellent resistance to flame. Deformation, ozone, oils, acids and chemicals. Oil resistant insulation and jacket. Abrasion resistant. Flexible in cold temperatures. ICEA Method 1. Table E-1. Designation Background or Base Color 1 Black, 2 White, 3 Red, 4 Green, 5 Orange, 6 Blue, What do all SO Cord letter designations stand for? See the table below for a simple breakdown. Designation What this means S Service grade. Extra hard service when not followed by J. P, or V. J Hard service, V Vacuum cleaner cord and light duty cable. P Parallel cord(also known as zip cord) Light duty only. E Thermoplastic Elastomer(UL/NEC designation only) O Oil resistant* T Thermoplastic, W Outdoor. Sunlight-resistant jacket. Wet location rated conductors. Formerly"W-A" H Heater cable, VW-1 Flame retardant, FT2 Flame retardant, When one"O" is in a designation(for example. SJOW" only the outer jacket material is oil resistant. If there are two"O's" are in the classification(such as"SOOW" both the outer jacket and conductor insulation are oil resistant.
$
65.99
Buy It Now
Free Shipping
Condition: New
Location: Chicago, United States
Copper wire, THWN, building wire, hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, etc…. 14 Gauge THHN ... moreStranded Copper Building Wire. Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC).
$
228.08
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
279.78
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
35.00
Buy It Now
$6.25 Shipping
Condition: New
Location: Huntington Station, United States
MRC CSFJ CONDUCTOR ACCOMMODATION TYPE SLANT LUG W/ONE HOLE SINGLE END. PRICE IS FOR 42 PCS OF PART # MS77066-2. MRC AAKV MAXIMUM CONDUCTOR SIZE ACCOMMODATED ... more12 AWG. MRC AGTA BASIC SHAPE STYLE SOLDER, ANGULAR.
$
62.47
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
1 x #12 AWG Non-Insulated (Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). 3 x #12 AWG Solid Insulated Copper Conductors (Black,Red, and White).
$
159.99
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
National Electrical Code (NEC), NFPA 70. 1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
47.78
Buy It Now
Free Shipping
Condition: New
Location: Owings, United States
1 x #10 AWG Non-Insulated (Bare) Solid Copper Ground Wire. National Electrical Code (NEC), NFPA 70. Conductor Insulation is 90 °c Rated Polyvinyl Chloride ... more(PVC). Copper Conductors are Annealed (Soft) Copper, Solid or Compressed Stranded.
$
115.00
Buy It Now
Free Shipping
Condition: New
Location: Carlyle, United States
Jumper Cable. Alpha Wire. Bus Drop Cable. Aluminum URD Cable. Aluminum Service Drop Cable. Belden Cable. Diesel Locomotive Cable. Festoon Cable.
$
45.00
Buy It Now
Free Shipping
Condition: New – Open box
Location: Bhavnagar Wadva S.O, India
Thermal Overload Relay 3 Pole (NEW). The MITSUBISHI TH-N12 is a THERMAL OVERLOAD RELAY. Overload release current setting - min 2.8A. Overload release ... morecurrent setting - max 4.4A. MITSUBISHI TH-N12 3.6A(2.8-4.4A).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
 In