HP Agilent Microwave Frequency Counter 5342A Opt. 001 002
HP Agilent Microwave Frequency Counter 5342A Opt. 001 002 Although we welcome your questions and inquiries by e-mail or phone. Bidders are expected to do their own research in regard to the compatibility and/or software/driver requirements for any item they are considering purchasing. In most cases. All information that we have available to us is included in the text of the auction. HP Agilent Microwave Frequency Counter 5342A Opt. 001 002 Model No. 5342A Opt. 001 002 No manuals. Cables, probes, or other accessories included. Auction will include a power cord. Used. Powers up, untested any further, sold AS-IS. Actual unit shown. Condition Used, Warranty Sold As Is. No Warranty. This item is sold"As-Is" with no warranty. And will not be considered for either refund or exchange. This is an"All Sales Final" item. Domestic ... moreShipping Information Shipping via UPS. Buyer can specify ground or air. Buyer is responsible for shipping costs. International Shipping $15.00 service charge will be applied to international shipments. Warranty will be voided on items shipped internationally. Payment Payment can be made by PayPal. Visa, Mastercard and Discover. 8.0% Sales tax applies to items shipped within California. Contact Information Send questions through the eBay email system. Or call(714) 523-2425 8am- 4pm Pacific M-F. We are located in Anaheim. CA. View our other Items for Sale on Auction We accept Visa. Mastercard and Discover Powered by The free listing tool. List your items fast and easy and manage your active items.
|
|
HP 5342A Microwave Frequency Counter (tested good)
TESTED GOOD AND IN WORKING ORDER
|
|
HP MODEL 5342A MICROWAVE FREQUENCY COUNTER #2440A09228
HP MODEL 5342A MICROWAVE FREQUENCY COUNTER#2440A09228 Click Photos to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Click to Enlarge Description Used counter which does power up and gets the readout as shown. No further testing has been done. Sold"as is" No warranty offered. No returns accepted. Sorry no instruction manual or other accessories. Cosmetically clean with minor scuffs and scratches. PLEASE CLICK ON THE PICTURES TO GET A LARGER MORE DETAILED VIEW OF THE ITEM. We do our best to describe all items to the best of our ability.Please do not assume that accessories that are not shown are present or the condition of the item is other than described or pictured.Any questions please feel free to ask. Payment and Shipping PAYMENT TERMS: Payment must be received within seven days of the closing. Item will be re-listed ... moreafter this period if I have not heard from the winning bidder. SHIPPING TERMS: We ship via FedEx ground to the lower 48 states.At this time we are not offering our items to residents in Hawaii or Alaska.Items normally ship in 3 days or less once payment is made. inkfrog terapeak. I000000.
|
|
HP 5342A Microwave Frequency Counter Tested & Working Serial# 2134A04923
HP 5342A Microwave Frequency Counter Tested& Working Serial# 2134A04923 This is for a HP 5342A MICROWAVE FREQUENCY COUNTER THAT HAS BEEN TESTED AND IS WORKING. SERIAL# 2134A04923 Model Details The 5342A Frequency Counter is particularly useful in the communication field since it can tolerate an FM carrier frequency of up to 50MHz peak to peak. ▪ Provides automatic frequency measurement to 18GHz in a highly portable package ▪ Selectable input attenuation of 50 ohms and 1 Mohm ▪ Two input frequency ranges: 10Hz to 500MHz& 500MHz to 18GHz. ▪ Utilizes microprocessor technology ▪ Keyboard allows you to perform various math functions to allow for such things as IF offsets ▪ An 11-digit display is sectionalized for easy readout to 1Hz resolution No Option cards are included with this model. Please Contact us with any Questions. THANK YOU ... moreFOR LOOKING. WE APPRECIATE YOUR BUSINESS NOW& IN THE FUTURE. WE SPECIALIZE IN ALL ASPECTS OF BROADCAST POST PRODUCTION. TEST AND MEASUREMENT AND CAN PROVIDE ANY ACCESSORIES OR EQUIPMENT IN ORDER TO FULFILL YOUR NEEDS. Pay with your credit card through PayPal. All California residents will be charged state and/or local sales tax at the time of checkout. Payment must be received within 7 days of the close of auction. If payment isn't received within 7 days. The auction will be revoked and a Non-Paying Bidder alert will be filed. Packages are usually shipped within 24 hours of payment receipt(excluding Saturday/Sunday) Shipping costs for all orders can be determined by the shipping calculator in this auction. All orders are shipped via UPS. FedEx, or USPS. International buyers, please be aware that you may incur a brokerage and/or customs fee upon delivery. Winning bidder is responsible for shipping charges. We reserve the right to choose carrier based on shipping method selected at time of payment. Combined shipping is done at the sellers discretion. If you purchase more than one item from us. They may arrive in separate packages. Telephone: 1-800-542-0646. ANY RETURNS WOU
|
|
HP Hewlett Packard Agilent 5342A Microwave Frequency Counter Option 001 & 011
HP Hewlett Packard Agilent 5342A Microwave Frequency Counter Option 001& 011 HP Hewlett Packard Agilent 5342A Microwave Frequency Counter Option 001& 011 Details: 1) HP Hewlett Packard Agilent 5342A Microwave Frequency Counter Option 001& 011 Condition: Good cosmetic condition with some minor scuffs and scratches as shown. Please refer to the photos for more details. Tested: Was removed from a working environment. I was able to power it on and it is responsive to the controls when manipulated. The display is bright and easy to read. No further testing. Warranty: 14-Day Right-of-Return SKU: 392186-D Please review our Help page for all of our Terms and Conditions before bidding or purchasing. By bidding or purchasing our merchandise. You are agreeing to these terms and conditions. Questions? Send us a message SALE TERMS AND CONDITIONS: ... moreOnly the pictured items are included in the listing. If it is not pictured or mentioned in the description it is not included. Place a bid only if you intend to purchase the item. If payment is not received within 3 days. The item(s) will be relisted at our discretion. PAYMENT INFORMATION: Payments are expected in a timely manner. Please contact us in the event that payment cannot be made within three days. Payment arrangements can be made. We accept: PayPal. All Major Credit Cards, and Bank Wire Transfers in USD(There is a $25 wire transfer fee) A 8.75% Sales tax applies to CALIFORNIA residents unless a resale tax ID is provided for our records. We cannot process the order until we receive sales tax or a copy of your tax ID. If you would like to pay using a credit card. Please call us at(408) 743-5609. Resellers Click Here* WARRANTY: Please see listing above for the warranty that applies to this item. AS-IS. No Warranty: When an item is stated as being AS-IS. The condition of the item is either unknown or has known issues(as stated in the description) and does NOT carry any warranty and NO returns will be accepted for this item. 14-Day Right-of-Return: You have fo
|
|
AGILENT HP 5342A 500MHZ-18GHZ MICROWAVE FREQUENCY COUNTER
ebay template AGILENT HP 5342A 500MHZ-18GHZ MICROWAVE FREQUENCY COUNTER. Click on the Enlarge button to see more images, Item Functionality, 50% AS-IS(Untested) Packaging, Not original packaging, Item Condition, 75% Great(Item looks presentable- shows signs of visible wear) AGILENT HP 5342A 500MHZ-18GHZ MICROWAVE FREQUENCY COUNTER, This listing is for an HP 5342A 500MHz-18GHz Microwave Frequency Counter with Option 001. Unit has been successfully tested for power. It did not read the RF signal being sent to it from the signal generator. No accessories/cables are included. It appears to be in good cosmetic condition with some signs of use/wear. See pix. Packed weight is about 9 lbs. Condition: AS-IS Warranty: No Returns on AS-IS Items Click on the blue Enlarge button inside of the listing. Not the one near the title, to see more pix including ... morethe back of the unit. Manufacturer: AGILENT HP, Model: 5342A, 500MHZ-18GHZ MICROWAVE FREQUENCY COUNTER, Shipping is via UPS. Not USPS! No PO Boxes!I usually ship on the same or next business day payment is received. You will receive the tracking number from carrier directly to your PayPal or eBay email address. All international bidders: please confirm shipping method and cost with me before placing the bid. I will need a complete postal address. Absolutely No Economy. Surface or Other Risky Shipment Methods Internationally, So PLEASE Do Not Inquire! Please include your telephone number with your payment for customs forms. Thanks for your consideration and welcome back for more purchases! Please read" which gives you more info about the company's policies. Please email Damon at bpaillc.com or call me 410-662-6380 and ask for Damon should you have any questions or concerns! Paypal preferred. Powers Your Online Marketplace Grow your business. Not your staff with Kyozou
|
|
HP 5342A Microwave Frequency Counter Opt 001, 005
You are purchasing an HP 5342A Microwave Frequency Counter Opt 001 and 005. 4" x 3" lettering on side of unit not removable Payment through PayPal. Contact us with any questions.
|
|
HP 5342A Microwave Frequency Counter w/ Opt 01
You are purchasing an HP 5342A Opt 01 Microwave Frequency Counter. Unit has 2 feet missing from back of unit. The feet are included. But aren't attached to unit. Payment through PayPal. Contact us with any questions.
|
|
AGILENT HP 5342A MICROWAVE FREQUENCY COUNTER with OPT 01 02 011
Up for sale is a used AGILENT HP 5342A MICROWAVE FREQUENCY COUNTER with OPT 01 02 011 as can be seen in the pictures. This item was pulled out of a working environment but has been tested for power on ONLY. Therefore, it's sold as-is, as described. Included in this auction is the HP 5342A as described/pictured ONLY. Nothing else is included. The estimated shipping calculator is not always accurate. I only charge actual shipping cost so please wait for me to send you the total price before payment. This also applies to Canadian residents please wait until I get back to you with your total including shipping and applicable taxes. IF YOU HAVE A 0 OR NEGATIVE RATING. PLEASE CONTACT US PRIOR TO BIDDING OTHERWISE YOUR BID MAY BE CANCELLED. PLEASE MAKE SURE YOU KNOW WHAT YOU ARE BIDDING ON BEFORE PLACING A BID OR ASK FOR MORE DETAILS! Canadian ... morebuyers will have to add the appropriate GST/HST on purchase price. International Buyers- Please Note: Import duties. Taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Customs fees are normally charged by the shipping company or collected when you pick the item up. These fees are not additional shipping charges. This item is sold AS-IS and AS DESCRIBED. Payment is expected within 5 business days after end of auction. Please email me if you have any further questions or if you would like other accepted payment methods. I will leave feedback after I have received feedback.
|
|
HP Hewlett Packard 5342A Microwave Frequency Counter & Manual - Opt 001 004 011
HP Hewlett Packard 5342A Microwave Frequency Counter& Service Manual- Options 001 004 011 The HP 5342A Microwave Counter provides automatic frequency measurement to 18 GHz. Features•Automatic measurements to 18 GHz•Wide FM tolerance•Scaling and offset functions Included Options•Oven-controlled crystal oscillator time base(Option 001) Digital-To-Analog Converter(Option 004) Option 004 lets you convert any three consecutive displayed digits(frequency or amplitude) into an analog voltage output on the rear panel. This makes the monitoring of microwave-oscillator-frequency drift easy to make with only a stripchart recorder. HP-IB interface(Option 011) Specifications Frequency range 10 Hz to 18 GHz, Sensitivity 500 MHz to 12.4 GHz: 25 dBm 12.4 GHz to 18 GHz: 20 dBm, Dimensions 5.25" H x 8.38" W x 19.6" D, Shipping Weight 28 ... morelbs, Serial Number 2428A08826, Includes searchable PDF Operation and Service Manual on CD. Removed from working lab. Excellent condition and very clean. related: agilent 5343A 53150A
|
|
HP 5342A Microwave Frequency Counter 10Hz-18Ghz
HP 5342A Microwave frequency Counter. Meter is shown with 1Ghz input from my IFR 1200S also shown are inputs to the BNC connector of 500Mhz. Meter has signs of use. Case has some scratches, no dents. Meter comes as shown without IFR 1200S or power cable or input connectors. Some noise from the fan but does not sound like a bad bearing.
|
|
HEWLETT PACKARD 5342A 18 GHz. MICROWAVE FREQUENCY COUNTER OPTIONS 001 & 002
For sale is one Hewlett Packard 5342A counter in good working order. The first photo is with an input of 2.2 GHz.Input level 0 Dbm. The second photo is with an input frequency of 10 MHz. from a Racal 9475 rubidium frequency standard.The photos are of the counter being sold. Description: The HP 5342 A Microwave Frequency Counter provides automatic frequency measurement up to 18 GHz. The powerful and versatile microprocessor controlled keyboards can accomplish offset tasks as a standard feature as well as providing user interactive diagnostic information. The eleven digit display is sectionalized for easy readout to 1 Hz resolution. Wide FM tolerance- High sensitivity- Automatic or manual operation Frequency range(2 inputs) 10Hz.520MHz and 500MHz.18 GHz Note: The instrument was probably" rack mounted" as it has no feet. Weight: With ... morepackaging the instrument weighs 9 Kilos. Shipment to mainland continental Europe costs £23 to £35 depending on zone Powered by
|
|
HEWLETT PACKARD HP AGILENT 5342A MICROWAVE FREQUENCY COUNTER 18GHZ PARTS
TESTING& COSMETIC NOTES: This is a KNOWN BAD/ PARTS& REPAIR item in FAIR cosmetic condition that IS NOT WORKING and is SOLD AS-IS/ NOT GUARANTEED The fan turns on. But the display does not work properly. When switched from on to standby, the display flickers on then off. It is unknown if anything other than the display is not working. COMPONENTS INCLUDED IN THIS AUCTION: 1) HEWLETT PACKARD HP AGILENT 5342A MICROWAVE FREQUENCY COUNTER 18GHZ PARTS PARTS OR REPAIR- ONLY GUARANTEED TO BE AS PICTURED: Our descriptions. And photos represent our best effort to relay all pertinent information about a product. We assure the buyer that they will receive the quantity, components, and level of operation shown in the photos. This does not represent a guarantee or warranty about the item's functionality beyond what is depicted in the photos. ... moreWe expect to receive less money for items sold in this condition; as a trade-off, we do not accept returns or offer refunds. We ask that our prospective buyers take these purchase terms into account and bid accordingly. ADDITIONAL INFORMATION: See the following link to a HP journal article about the item: http:www.hpl.hp.com/hpjournal/pdfs/IssuePDFs/1978-05.pdf See the following link to specifications of the item: http:www.atecorp.com/ATECorp/media/pdfs/data-sheets/Agilent-5342-5343_Datasheet.pdf Please Click Here and Read Our Sales Policies at" at" src="http:ocdepot.com/template/Rounded_Middle_Right.gif" at" src="http:ocdepot.com/template/Rounded_Left_Bottom.gif" at" at" src="http:ocdepot.com/template/Rounded_Middle_Bottom.gif" at" src="http:ocdepot.com/template/Rounded_Right_Bottom.gif" SearchBy8- 55761 | Location: F02 | Lister: Sean | Tester: TESTER NAME HERE' | Tech: | Quan: 1 | List: 1 | Duplicate: False | Plan: D(Single Item) | Amazon: Size: 0x0x0 Weight: 27 | Start: $99.99 | BIN: $0.00 | Type: Auction | $hippingBump: $0 | Date: 12/16/2013 | Condition: Known Bad/ Parts& Repair | CONSIGNOR VIDE O
|
|
HP Agilent 5342A Microwave Frequency Counter (10Hz-18GHz)
HP Agilent 5342A Microwave Frequency Counter(10Hz-18GHz) HP Agilent 5342A Microwave Frequency Counter This HP Agilent model 5342A/ Opt: 001. 011 Microwave Frequency Counter(10Hz-18GHz) powers up, initializes, responds to controls, accepts and displays input. This item is in otherwise good physical condition and is being sold with a 14 day DOA warranty. Handling Charge: $19.95(included in shipping above) ESSSURPLUS is proud to have our 16.000+ repeat customer feedback for you to review. Thank you for looking. And Good Luck if you're bidding! Important: Auction winners have 7 days to complete the purchase of item(s) won. Feel free to contact our office for assistance in the completion of your transaction if you are having difficulty. The auction item will be relisted or sold after the 7 day window. Thank you for your assistance. Please ... moreNote: We DO NOT ship outside of the United States. However, Non-US buyers may have or find a US shipping address. Condition: Used andale andalesell. Click Images to Enlarge Payment Options: PayPal Shipping Options: Domestic shipping: Weight based Shipping Charges. Domestic Carriers are: Ups Ground I will ship to: United States[Weight] 45 lbs. Shipping and Handling: Electronic Surplus Services a pretty image. with Vendio Research. Vendio provides powerful selling automation for sellers of all sizes. Click Here. Double your traffic. Get Vendio Gallery- Now FREE!
|
|
Agilent HP 5342A 18 GHz Microwave Frequency Counter Options 001 NICE Warranty
HP 5342A 18 GHz Microwave Frequency Counter Late Model Options 001- HS Time Base 15 Day Warranty
|
|
HP 5342A Microwave Frequency Counter - Excellent Working Condition
HP 5342A Microwave Frequency Counter with Option 001(Oven Stabilized 10 MHz clock) Option 001: Model 10811 S/N: 2332A18474 was added to this counter during alignment. The10 MHz clock frequency was set to 10.000000 MHz +/ 0.1 Hz using a Rubidium Secondary Standard after warm up. Basic Specifications: Input 1: High Frequency N- connector Frequency Range: 500 MHz- 18 GHz Sensitivity: 25 dBm to 12.4 GHz; 20 dBm 12.4- 18 GHz Input 2: Low Frequency BNC connector Frequency Range: 10 Hz to 500 MHz Sensitivity: 50 Ohm. 25 mv rms; 1 M Ohm, 50 mv rms, 10 Hz to 25 MHz HP 5342A S/N: 2440A09602 See photos for sensitivity and frequency measurements. This counter has been aligned to HP specifications and meets or exceeds all sensitivity specifications. Note: The measurements at 5.6 GHz to 18 GHz were made using a HP 8684D Cavity Tuned Generator which has ... morelimited frequency resolution and can be set to only 18.00 GHz- the HP counter is much more accurate. The HP 8648C was used primarily to verify the HP counter sensitivity. Shipping will be FedEx Ground with full insurance for selling price. I ship to Continental USA ONLY. I only accept PayPal for payment. Paypal payment is expected within 24 hours of close of auction.
|
|
CL6E08 HP 5342A Microwave Frequency Counter Used Hewlett Packard
HP 5342A Microwave Frequency Converter DESCRIPTION Item is tested and powers on; no further testing was able to be performed. Item is USED in FAIR cosmetic condition with heavier than normal wear from use. Including missing foot on front bottom right as pictured. AUCTION INCLUDES HP 5342A Microwave Frequency Converter Power Cord AUCTION DOES NOT INCLUDE Manual Original Packaging WARRANTY INFORMATION 30-Day Hassle-Free DOA Warranty! CONTACT US Store hours: Monday- Friday 7AM- 4PM Central Time Closed: Saturday& Sunday. We are also closed on holidays. Address: 11543 S. Memorial Parkway Huntsville. AL 35803 PAYMENT Payment is due within 7 days of the auction's close. Payment is only accepted by PayPal and eCheck payments Before paying. Ensure both your eBay Ship To address is the same as your PayPal Ship To address. Local pickup fee is ... more$10.00. BUYERS MUST PICKUP LOCAL ITEMS WITHIN 10 BUSINESS DAYS OF PAYMENT* SHIPPING We ship within five business days from the day of your Cleared Payment! Once your item has shipped the tracking information will be available in your eBay account. We only ship within the 48 contiguous states in America. WARRANTY If your item is covered under our 30-Day DOA Warranty. You may return this at anytime within 30 days. Buyer pays return shipping! We will provide a full refund for the original sale price. This does not include shipping fees. When bidding on an item that is'SOLD AS IS' please take notice that this item has NO warranty and we will not be able to provide you with a refund.
|
|
HP 5342A Microwave Frequency Counter. Option: 001, 011. 10Hz to 18GHz, Good
HP 5342A Microwave Frequency Counter. Option: 001. 011. 10Hz to 18GHz, Good Frequency Range: 10Hz to 18GHz. Sensitivity: Input#1: 10Hz to 520MHz-25mV. Input#2: 500MHz to 18GHz- 30dBm. Maximum Input: +7dBm. Number of digits: Input#1-9 digits. Input#2-11 digits. Option 001-High stability time base. Option 011-HP-IB. PDF of specifications: NOTE-NOTE-Both inputs have been tested as shown in the first two pictures. These inputs meet specifications. This unit is fully operational and in good condition. Shipping anywhere outside the USA will be via USPS priority international. Shipments to Alaska. Hawaii or US Territories require you to contact me for shipping options and cost. They will not ship at the quoted US shipping cost. For shipments outside the USA please contact me for shipping options and cost as they vary from country to country. Payment ... morefrom outside the USA must be made by PayPal. I ask that the winning bidder pay for this sale within 3 days of sale end. Good luck in bidding, testeq
|
|
HP 5342A 18 GHz Microwave Frequency Counter & Operations Manual
For sale is a used HP 4352A Microwave Frequency Counter. The unit powers up and functions the majority of the time. Every once in a while the unit will power up and then start cycling off and on. This has been notice most often when the unit is cold(below 50 degrees Fahrenheit) The test frequencies in the second and third pictures are 100 MHz as measured on the low frequency input and 1600 MHz as measured on the high frequency input. There is no calibration history on the unit. The unit has the GPIB interface and includes the Operations Manual. This is a no return listing so please ask questions prior to purchase. I am always happy to answer questions.
|
|
HP 5342A MICROWAVE FREQUENCY COUNTER OPT 01, 06 011 INTERMITTANT FUNCTIONALITY
HP 5342A MICROWAVE FREQUENCY COUNTER OPT 01. 06 011 INTERMITTANT FUNCTIONALITY Condition: Powers-up and will sometimes function and other times locks up. Will require unknown repair(s) Package Specifcs: Packaged Weight: 26 lb. Packaging Charge: $0.00, Shipping: Shipping Information: Before purchasing the item. Please remember the following: This item is not available for International Bidding or Shipping. USPS will ship to PO Boxes and street address. UPS will only ship to street address. Please use the shipping calculator on this page for shipping charges to your zip code. You will be responsible for paying these shipping charges in addition to the sale price should you win. Handling charges are included in the shipping calculator. Delivery to a United States address should be expected in 7-10 days after funds have been received and cleared ... morethrough either our Pay Pal account(Pay Pal payment) or bank account(money order or check) We ship after we have verification of funds. Normally. UPS Ground delivery is 4 days after it is placed in their system, but, unfortunately, we cannot gurrantee the rate of speed of UPS. Please understand, we cannot be held responsible for delivery delays or damages caused by UPS. All items are shipped insured in the amount of the item's final sale price. Once your item is shipped. Tracking information will be uploaded to eBay. Click the logo below to track your shipment. Payment Options We accept the following forms of Payment: Pay Pal Credit Cards- Credit card or debit card processed through the seller's Internet merchant account. Export Control/ITAR Liability Please read carefully. By purchasing this item. You are doing so knowing and agreeing to the following conditions and agree to hold harmless Test Gear Nation Incorporated and all its agents should you improperly export this item. This item may be designated an Export Control Item. The use. Disposition, export and re-export of this item is subject to all applicable United States Laws and Regulations. This includes the
|
|
HP 5342A Microwave Frequency Counter Used Hewlett Packard 5342 A
Hewlett Packard 5342A Microwave Frequency Counter For sale is a used. HP 5342A Microwave Frequency Counter. This counter has been tested for power up only. As you can see from the photos above, the unit does power up. The power cord does not come with the unit, it is only to show it working. We are selling this as is, for parts and/or repair only. I am unsure what is wrong with the display, but it does not appear to work correctly. It has been used. So cosmetically there are some scratches on the front and around the unit. It could use a good cleaning! All knobs and buttons appear to be in fine shape though! Again, we have not tested this past power up. Please read below. The owner of Fredrich Electronics. My father, was recently injured very badly in an accident. We are praying he will make a recovery; however, the road ahead is a very long ... moreone. The accident has left my mother in need of someone to manage family business affairs. I am selling a wide variety of electronic equipment from his workbench, along with antique Aladdin lamps, glassware, and many other unique and rare items he has collected over the years. I can only assume that the equipment on his workbench has full functionality. Please bid accordingly. Thanks and HAPPY BIDDING! ALL ITEMS WILL BE SHIPPED WITHIN 1 BUSINESS DAY. FROM OUR SHOP IN CENTRAL MISSOURI, ENSURING FAST SHIPPING TIME! Fredrich Electronics Serving Boonville. Missouri for Over 40 Years! Fast Shipping from Central Missouri! Specializing in hand made ham radio cables& accessories! NOTICE TO ALL BUYERS: Customer satisfaction is#1 to us! We strive to ensure that each piece of equipment that leaves our door has been properly described and priced accordingly. If you do not feel 100% satisfied with your purchase. Please contact us via phone or email before leaving feedback. Give us a chance to make it right! Your Paypal mailing address MUST match your eBay mailing address. We will not ship items with discrepancies. And buyers doing this will be reported. Buyer is responsible for provid
|
|
HP 5342A GENUINE MICROWAVE FREQUENCY COUNTER 10Hz - 18GHz
THIS SALE IS FOR 1 HP 5342A MICROWAVE FREQUENCY COUNTER. HAS BEEN TESTED FOR FUNCTIONALITY. POWERS ON AND OFF NORMALLY. ALL FUNCTIONS WORK. PULLED FROM A WORKING ENVIRONMENT. UNIT ONLY. HP 5342A MICROWAVE FREQUENCY COUNTER 10Hz- 18GHz IF ITS NOT LISTED IN THE AUCTION OR PICTURED IN THE AUCTION DO NOT ASSUME ITS INCLUDED IN THE AUCTION.
|
|
HEWLETT PACKARD HP 5342A MICROWAVE FREQUENCY COUNTER OPTION-H16 AS-IS
Normal 0 false false false EN-US X-NONE X-NONE For Auction HEWLETT PACKARD HP 5342A MICROWAVE FREQUENCY COUNTER OPTION-H16 AS-IS Description Up for bid a Vintage Hewlett Packard HP 5342A Microwave Frequency Counter Option H16. It powers up and the fan works fine. However the SAMPLE RATE“hold-knob” is missing. Also the threaded-connector is skewed. Not straight, looks recessed at an angle(see pictures) The Counter can be fixed or used for parts. Otherwise. Cosmetically in very good condition with some scratches and scuffs. Item is sold exactly as pictured. No power cord, or any other accessories are included. Item sold AS-IS, sales final, no returns. Sorry no International shipping for this item. Feel free to ask any questions you may have BEFORE YOU BID and I will be glad to answer you. Please view the pictures for more details and buy with ... morefull confidence. Thanks for looking and bidding! Included Agilent/Hewlett Packard HP 5342A Microwave Frequency Counter Option H16 SN: 2228A60638. As pictured. Remarks The pictures are of the item you will receive. I do not profess to be an expert for item from a surplus sale. However item is listed as seen and best effort made to describe item. PLEASE VIEW ALL THE PICTURES FOR DETAILS. I am available to answer any questions you may have. Key Features Brand: HP Model: 5342A(Microwave Frequency Counter Option H16) Export Control/ITAR Liability Please read carefully. By purchasing this item. You are doing so knowing and agreeing to the following conditions and agree to hold harmless lister: AKOKOMAN and all its’ agents should you improperly export this item. This item may be designated an“Export Control Item. The use. Disposition, export and re-export of this item is subject to all applicable United States Laws and Regulations. This includes the Export Administration Control Act of 1979(50 USC.2401, et, seq) the Arms Export Administration Control Act(22 USC2751, et, seq) the International Traffic in Arms Regulation(22 CFR 121) and the Export Administration Regulation
|
|
HP 5342A GENUINE MICROWAVE FREQUENCY COUNTER 10Hz - 18Hz T6-A.2
TECHWASTE RECYCLING. LLC EARTH- FRIENDLY ELECTRONIC REUSE& RECOVERY 1940 E Occidental St Santa Ana. CA 92705 CONTACT: 714-813-5390 HOURS OF OPERATION: 8am-4pm MON-FRI IF ITS NOT LISTED IN THE AUCTION OR PICTURED IN THE AUCTION DO NOT ASSUME ITS INCLUDED IN THE AUCTION. DESCRIPTION THIS SALE IS FOR AN HP 5342A MICROWAVE FREQUENCY COUNTER. HAS BEEN TESTED FOR FUNCTIONALITY. POWERS ON AND OFF NORMALLY. ALL FUNCTIONS WORK. PULLED FROM A WORKING ENVIRONMENT. COMES WITH UNIT AND POWER CABLE ONLY. HP 5342A GENUINE MICROWAVE FREQUENCY COUNTER 10Hz- 18Hz T1-A2 LOCATION: T1-A2 PRODUCT DISCLAIMER/SHIPPING WE DO NOT TRANSFER OWNERSHIP. RESET PASSWORDS OR INCLUDE ANY SOFTWARE UNLESS STATED IN THE AUCTION. PLEASE ASK QUESTIONS BEFORE PURCHASING ANY ITEMS. OUR GOAL IS 100% CUSTOMER SATISFACTION AND TO ENSURE A POSITIVE EBAY EXPERIENCE. WE RESERVE THE ... moreRIGHT TO SHIP PRODUCTS USPS. FEDEX SMARTPOST AND FEDEX GROUND. RcmdId ViewItemDescV4,RlogId p4%60bo7%60jtb9%3Feog4d71f%2B%3F4f%3E-1475fc3f298-0x10f-
|
|
HP Agilent 5342A Microwave Frequency Counter Unit Opt 001, 011 Industrial PARTS
Search our eBay Store! HP Agilent 5342A Microwave Frequency Counter Unit Opt 001. 011 Industrial PARTS SKU: JV-MAT-A-MICROWAVE5342 Condition: For parts or not working Packaging: OEM Warranty: AS-IS FOR PARTS OR REPAIR This auction only comes with what is pictured or listed in the description. All parts. Accessories, cables, etc. are only included if pictured or listed in description. If in doubt, please contact us before purchasing. Click an Image to Enlarge HP Agilent 5342A Microwave Frequency Counter Unit Opt 001. 011 Industrial PARTS BEING SOLD AS-IS FOR PARTS OR REPAIR Model: 5342A· Unit powers on with functional display and responsive controls. Unit displays error message whenever any of the number keys are pressed. Dimensions(L”xW”xH” 20.5*8.5*5.25 As a large liquidator for many vendors. Our rating system is as follows. On a scale ... morefrom 1- 10. With 10 being in new or excellent condition, this item is rated as a 7. SEE PHOTOS. All images taken in house of the unit(s) being sold. Except for multiple quantities where item received will be in similar or better condition. Please review images thoroughly before purchasing. Additional information may be found searching online. We do not have additional info. Only pictured items will be included. All parts. Including accessories and cables are only in cluded if pictured or listed in the description. All pictures are taken in house. If you require more information. Please contact the manufacturer and/or research online. As a large liquidator, we do not carry additional information beyond what has been provided to us above. This FDA DISCLAIMER is for MEDICAL DEVICES only and not for all our products: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so. D0 N0T bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. This unit has been
|
|
HP / Agilent 5342A MICROWAVE FREQUENCY COUNTER 10Hz - 18Ghz Opt's 001-002-011
HP/ Agilent 5342A MICROWAVE FREQUENCY COUNTER 10Hz- 18Ghz Opt's 001-002-011 Item was removed from a local semi-conductor business in good condition. UPS Shipping within US continent(lower 48 states only) Any questions. Feel welcome to email us!
|
|
HP/Agilent 5342A Microwave Frequency Counter 18GHz See picture
HP 5342A Microwave Frequency Counter Unit Has Option 011 GPIB and Option 001 High Stability Time Base Last Calid in 2012 Seal still intact. Unit Is in Excellent Working Condition I show it working to 20 GHz at-25 dBm Shown also at at 2 Ghz and 100MHz Input A 10Hz-500Mhz Input B 500MHz-18GHz Questions Call 540-775-0495 or email
|
|
HP Agilent 5342A Microwave Frequency Counter - Option 002 Amplitude Measurement
The Agilent 5342A is an automatic CW microwave frequency counter featuring-25 dB sensitivity. Frequency range: 500 MHz to 18 GHz; 500 MHz to 18 GHz(input 1) 10 Hz to 520 MHz(input 2) Sensitivity: 25 dB to 12.4 GHz. 20 dB 12.4 GHz Maximum input: +7 dB Coupling: dc to 50 ohm termination. Ac to instrument Input impedance: 50 ohm(input 1) 50 ohm or 1 megohm(input 2) Standard time base accuracy: 10 MHz. Eleven digit LED display* Amplitude measurement(Option 002) N(f) connector 100. 120/220, 240 Vac, +5% 10% 48-66 Hz operation* Option 002 adds the ability to measure and display the power level of the input in dBm. The 11 digit LED display presents amplitude measurement to 0.1 dBm resolution. Also the same option extends the instruments dynamic range to enable frequency measurements to + 22 dBm. Full spec. sheet can be viewed here- http:www.atecorp.com/ATECorp/media/pdfs/data-sheets/Agilent-5342-5343_Datasheet.pdf ... moreWe have many test electrical items available. Please visit our shop for more. Please note as we are a business our opening hours are Monday to Thursday 08:00-17:00. Friday 08:00-12:00. Extra delivery charges will be applied for Channel Islands. Isle of Wight, Isle of Man, Scilly Isles, Northern Ireland& Scottish Highlands. Should you require delivery to any of these areas please contact us before purchase. Will ship worldwide please contact us for a price. All our items are Ex-MoD Surplus and are sold as is basis without warranty. Calibration or test unless otherwise stated.
|
|
HP 5342A MICROWAVE FREQUENCY COUNTER, 18 GHz, 50/1M OHM SWITCH, OPTION H16, HPIB
HP 5342A Microwave Frequency Counter to 18GHz This frequency counter provides automatic frequency measurement to 18GHz. Selectable input attenuation of 50ohms and 1Mohm. Two input frequency ranges: 10Hz to 500MHz& 500MHz to 18GHz. We were able to test the unit up to 2.7GHz but that's as high as our signal generator goes. Cannot speak to it's calibration accuracy as it has not been recently calibrated(nor has the signal generator we used to test it to 2.7 GHz) Has a small impact fracture in the red display filter. Over the least significant digits(does not significantly effect readability) Remarkably clean and in good shape for it's age. Has served us well for our 2.4GHz Radio and Bluetooth development work. This unit is heavy(~ 21 lbs unboxed) but if the shipping amount still seems ridiculous(from ebay's automated calculation) ... morecontact us for the best rate. Normal 0 USA and Canada only please. Terms and Conditions: Due to the recent increases in Canada Post's international shipping costs. It is no longer feasible to consider international shipping of insured items, or items that cannot be shipped by small packets. Sorry and sadly. No more international shipping, USA and Canada only. Payment: The winner required to complete the transaction within 3 days of the end of auction. We accept only Paypal for payment. Shipping: Any questions about shipping please ask before bidding. Brokerage fees and customs charges can be very expensive with any carrier. Unfortunately these fees can not be predicted prior to shipment and we are not responsible for any of these fees. By bidding on this auction you have agreed to pay for any related brokerage. Customs, or import tax, fees. Please. Check your country's Customs rules before bidding· Shipping& Handling charges are not refundable under any circumstances. We only ship to the Paypal(eBay) confirmed address. Please update your address before you pay the order. We are not responsible for undeliverable or lost packages due to an incorrect Paypal
|
|
HP/Agilent 5342A 500MHz-18GHz Microwave Frequency Counter w/ Option 002
Serial# 2636A11058(M-00) Here we have for your consideration the HP 5342A Microwave Frequency Counter. We are selling the unit as is- no returns. Not fully tested. Unit powers on but digits do not display correctly. All control knobs and buttons are responsive when selected. Connections are in good cosmetic condition. Fan sounds healthy. Includes power cord. Specifications: 120V. 48-66Hz, 100VA max Option 002: Amplitude Measurement Unit is in very good cosmetic condition with light scratches. BE SURE TO CHECK OUT OUR OTHER EBAY AUCTION SITES! spartasurplus and spartawholesale! BE SURE TO CHECK OUT OUR PHOTOS! YOU WILL BE RECEIVING THE EXACT ITEM SHOWN. THANK YOU For considering our item! We have been selling on ebay for over 12 years! Bid With Confidence!
|
|
Hewlett Packard HP 5342A Microwave Frequency Counter w/ OPT 011, 002, 004
FabExchange-Online Experienced& Professional Equipment Liquidation Manufacturer: Hewlett Packard Model: 5342A Microwave Frequency Counter with Options 011. 002, 004 Features: Automatic measurements to 18 GHz Portability Wide FM tolerance Amplitude measurement in dBm(Option 002) High input sensitivity Digital-to-analog converter(Option 004) Serial Number: 2636A11063 Condition: Physical- Used Mechanical- Fully Functional Other Information: For testing and inspection(Contact us for appointment) Shipping can be done at the buyer's request(Buyer is responsible for all Shipping Cost) Sales tax will be added for CA residents unless the buyer has a Reseller's Certificate Please check out our other Auctions!
|
|
HP 5342A microwave frequency counter 10Hz-18GHz (E4)
Here's an HP frequency counter. Powered it up and plugged it into a frequency generator. The reading is in the right neighborhood- might need calibration. But you'll have to handle that. We don't have a way to test higher frequency behavior, unfortunately. We're a surplus store. And we aren't experts with most of this stuff. So, we don't make any guarantees beyond what's stated in the listing& pictures. Please note that international shipping will cost more than domestic. Feel free to contact us with any questions via ebay. By giving us a call during business hours at 651.646.8653, or by visiting our St. Paul store!
|
|
HP Microwave Frequency Counter Model 5342A Hewlett Packard
For sale is a Hewlett Packard Model 5342A Microwave frequency Counter. The counter appears to be in good condition and powers on. This counter was not fully tested and may need calibration. This item is sold as is. Shipping will be a flat $20 to anywhere in the continental US. Buyer to pay for item in full within 48 hours of end of auction. Thanks for looking and good luck bidding! a;06d2.RcmdId ViewItemDescV4,RlogId p4%60bo7%60jtb9%3Fuk.rp73%28%3Ea%3B06d2-14905be447d-0x10d-
|
|
HP 5342A Microwave Frequency Counter Working Clean Options 001,006,011
I have been using this while testing and repairing various HP RF and Microwave equipment for the last few months. It is clean and reliable. The pictures show measurement of frequencies up to 8.4Ghz which is the highest signal source I have in my home lab. ALso. The pictures show top, sides and rear to be clean and the front panel is free of sticker scrapes, gouges and residue. The freuency measurements are all done at an output of-2dbm and a 10db attenuator for a signal level of-12dbm. I will include power cord and a collection of manuals on USB jump drive. Options 001 10 Mhz Time Base 006 39dbm limit(It has it. Just not sure what it all means) 011 GPIB(HPIB)
|
|
HP 5342A , 10 Hz to 18 GHz , Microwave Frequency Counter 5342 A
HP 5342A. 10 Hz to 18 GHz, Microwave Frequency Counter 5342 A This item is in good condition and comes with our 30 days warranty. Please read the following terms of sale carefully. These terms constitute a legally binding agreement( contract) between the seller and buyer. By bidding on. Or purchasing, the product posted in this eBay listing, the winning bidder agrees to and accepts all of the terms of sale stated below. TERMS OF SALE: Only what is shown in the eBay photo and mentioned in the listing is included. Anything else should be understood to not be included. For sale is for the eBay item only. No service or tech support are included, but if you have a question feel free to ask and we'll answer if we can. All sales are final. Please understand that this is an auction/liquidation environment, not a retail store, so make sure the ... moreitem is right for you, before bidding. PAYMENT: We accept payment by Paypal. And we only ship to the address which the buyer provides within the Paypal payment, no exceptions. If you would like to pay with a non-Paypal payment method. Please contact us before bidding to see if we can arrange something. Buyers are given 7 days from winning bid to pay. And payment is expected of all winning bidders If no payment is made within 7 days. An unpaid item reminder will be filed with eBay, and the buyer forfeits the auction win. We are required by state law to collect sales tax on all items shipping to a CA address. CA sales tax may be waived at our discretion. But only with a valid CA resale certificate- please contact us for resale exception*before* sending payment. DOMESTIC(US) SHIPPING: Local pickup is normally not available; exceptions are sometimes made. But only for higher-value orders. Please contact us first to see if we can make this arrangement for you, don't assume that we will be able to. We charge flat-rate shipping. And there is no extra cost to ship to AK, HI, PR, or PO boxes, these are all fine. Shipping cost includes packaging cost including time and materials. And
|
|
HP Agilent 5342A 18GHz Microwave Frequency Counter w/ Option 001 002 - Tested
RDR ELECTRONICS WILL ONLY SHIP TO U.S. ADDRESSES. FOREIGN BIDDERS WILL BE APPROVED TO BID ONLY AFTER PROVIDING A U.S. SHIPPING ADDRESS! Auction consisting of: 1- HP Agilent 5342A 18GHz Microwave Frequency Counter(s/n- 2244A06764) Option 001- High Stability Timebase Option 002- Amplitude Measurement 1- IEC Power Cord Only what is listed above and/or shown in the pictures below are included in this auction. This auction is for a nice Hewlett-Packard model 5342A microwave frequency counter. Unit has direct count input(BNC-f) for 10Hz to 500MHz(1Mohm& 50 Ohm) and harmonic count input(N-f) for 500MHz to 18GHz. Will handle FM modulation up to 50MHz. Comes with High-Stability Timebase option(10811 oscillator) and amplitude measurement(0.1dB resolution) Bottom of case has the feet and tilt-up stand. For more detailed information we have provided ... morethis link to the website. Unit weighs about 20 pounds. Handy unit to have around the test bench for the RF enthusiast. This unit has all the right options too. Used unit in good physical and electrical condition. The top cover does have'MICROWAVE' stenciled on it. We have powered this unit up and checked out both inputs(including input sensitivity) and it appears to be in good working order. This item is being sold with a 30-day warranty. Check the shipping calculator for S/H cost to your ZIP code. Item will be insured for the bid amount. To view all of our current E-bay auctions click on our RDR-Electronics Items for Sale Page link below! Click on any image for a more detailed view. Click on any image for a more detailed view. Click on any image for a more detailed view. Click on any image for a more detailed view. Click on any image for a more detailed view. Click on any image for a more detailed view. Terms and Conditions: There is no need for us to email you after the auction ends. Simply pay the amount of the winning bid plus the S/H indicated by the shipping calculator for your ZIP code. We do not try to make(or lose) money on our S/H cost. We try
|
|
HP/Agilent 5342A 10Hz-18GHz Microwave Frequency Counter w/Option 011 HP-IB
Search our eBay Store! HP/Agilent 5342A 10Hz-18GHz Microwave Frequency Counter w/Option 011 HP-IB SKU: JV-DAY-A-AGICOUNTER5342 Condition: Used Packaging: OEM Warranty: 30 day DOA Warranty This auction only comes with what is pictured or listed in the description. All parts. Accessories, cables, etc. are only included if pictured or listed in description. If in doubt, please contact us before purchasing. Click an Image to Enlarge New Page 1 HP/Agilent 5342A 10Hz-18GHz@1Hz Resolution 11-Digit Microwave Frequency Counter w/Option 011 Digital I/O HP-IB. Model: 5342A· Option: 011(Digital I/O HP-IB) Unit powers on with working fan. Display and buttons are responsive. When‘RESOLUTION’ buttons are pressed. 5-Error is displayed. Functionality is unknown. Stand and rubber feet are missing from bottom of unit. Dimensions(L”xW”xH” 20-5/8 x 8-1/2 ... morex 5-1/8. As a large liquidator for many vendors. Our rating system is as follows. On a scale from 1- 10. With 10 being in new or excellent condition, this item is rated as a 8. SEE PHOTOS. All images taken in house of the unit(s) being sold. Except for multiple quantities where item received will be in similar or better condition. Please review images thoroughly before purchasing. Additional information may be found searching online. We do not have additional info. Only pictured items will be included. All parts. Including accessories and cables are only in cluded if pictured or listed in the description. All pictures are taken in house. If you require more information. Please contact the manufacturer and/or research online. As a large liquidator, we do not carry additional information beyond what has been provided to us above. This FDA DISCLAIMER is for MEDICAL DEVICES only and not for all our products: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so. DO NOT bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will ve
|
|
HP 5342A Microwave Frequency Counter - 30 Day Warranty
Up For Auction is this: HP 5342A Microwave Frequency Counter- 30 Day Warranty Comes as shown Satisfaction Guaranteed! My Promise to You: You are buying from a person that truly cares about your satisfaction. I stand by every sale. My word is my honor. Kent Payments should be received within 3 calendar days from the auction end date. If you need longer. Contact me so I can note it, I am patient. I accept Visa/Mastercard and Paypal. Walk-ins are welcome and no shipping charged when done so. I keep a pot of coffee on for such. If you are not a"Verified" Paypal person(or use an eCheck) Understand I will not receive money for about 3 days. I will not ship until Paypal says"cleared" on my end. Verified" Paypal customers are credited instantly. I ACCEPT VISA/ Master Card call me at 775-232-7288 for instant processing International ... morebidders may incur local custom's fees that were not paid on this Ebay sale. Items shipped via FEDEX when possible Large items are shipped via palleted truck freight Please email me your phone number if it is not in your ebay form. This is needed by the shipper to prevent delivery problems. All rates are Ground rates unless specified otherwise Shipping rates are to the 48 contiguous United States Only. Military addresses and destinations outside the 48 states may incur higher shipping. I need a physical shipping address. Fedex will not ship to a PO Box. If you are buying multiples. Dont pay until you are done purchasing. Then email me you are done. I will combine shipping and give you a cheaper total. Some things are delicate or large and cant be combined, but most can. If I see a single paid item I go into ship-mode and process quickly and I may not spot your other item without your telling me. Most are processed same day. Sometimes 2(weekends and such) Let me know if it needs expedited and we will work something out on cost. Ebay charges me a fee. Instantly, for every listing once sold. After 7 days, if I do not receive payment, a"non payer" alert is
|
|
HP 5342A Microwave Frequency Counter ***SOLD AS IS FOR PARTS/REPAIR ONLY***
HP 5342A Microwave Frequency Counter powers up. But the display does not work. The LED power indicator lights up when powered on, but no display. Not fully tested. There are some scuffs and writing on the unit, see pictures for details. THIS ITEM IS SOLD AS IS FOR PARTS OR REPAIR. No returns. Power cable is included. No other cables are included. The HP 5342A Microwave Frequency Counter measures the frequency of signals in the range of 10 Hz to 18 GHz. With a basic sensitivity of-25 dBm. Signals in the frequency range of 10 Hz to 500 MHz are measured by the direct count method. Signals in the frequency range of 500 MHz to 18 GHz are down-converted to an IF by a heterodyne conversion technique for application to the counter circuits. The unique conversion technique employed results in high sensitivity and FM tolerance in addition to automatic ... moreamplitude discrimination. The counted IF is added to the local oscillator frequency to determine the unknown frequency for display. Serial No. 2317A08432 Purchased from overstock electrical test equipment auction. Check out our Ebay store for additional electronics. May combine shipping if purchasing two or more items. If interested in combined shipping. Please send an email prior to payment to receive a combined shipping invoice.
|
|
HP - AGILENT 5342A MICROWAVE FREQUENCY COUNTER W/OPT 001 & 011 ! CALIBRATED !
In these bad economic times. Get more“bang” for your money with tested, working and calibrated test equipment from AAA Equipment Resources INC. I AM A WELL KNOWN SELLER AND BUYER OF ALL WORKING TEST EQUIPMENT.WE OUR ONE OF EBAYS TOP SELLERS OF TESTED. WORKING, AND CALIBRATED TEST EQUIPTMENT FOR OVER TWELVE YEARS. I AM A MAN OF MY WORD. OUR GOAL IS TO EXCEED CUSTOMER’S EXPECTATIONS. YOU ARE BUYING A PROFESSIONALLY TESTED AND CHECKED OUT AS FULLY FUNCTIONAL, HP- AGILENT 5342A MICROWAVE FREQUENCY COUNTER WITH OPTION 001 AND 011. Option 001 is High-Stability Timebase, and Option 011 is Digital Input/ output HP-IB. It was just calibrated. Due Date 12/07/15. The unit is in good to great cosmetic condition with a small scratch here or there. The top cover has a 14 marked on the top(see picture) The back and bottom feet are missing. All buttons, ... moreknobs, and switches are good and intact. The serial# is 2317A08004. Works with 120& 240 voltage. We always re-check the item before we ship it. This makes sure the item is working when it left my shop. WE WILL RE-CALIBRATED THE UNIT BEFORE SHIPPING AND A NIST TRACEABLE CALIBRATION CERTIFICATE. WILL BE PROVIDED AFTER ITEM IS RECEIVED AND IS ACCEPTED AS WORKING WITH IN SPECS. WE WILL MAIL OUT THE CERTIFICATE. THE RE-CALIBRATION DELAYS THE SHIPPING TIME THREE(3) DAYS. The 5342A Frequency Counter provides automatic frequency measurement to 18GHz in a highly portable package. Selectable input attenuation of 50 ohms and 1 Megohm. Two input frequency ranges: 10Hz to 500MHz& 500MHz to 18GHz. The 5342A is particularly useful in the communication field since it can tolerate an FM carrier frequency of up to 50MHz peak to peak. Because it utilizes microprocessor technology. The keyboard allows you to perform various math functions to allow for such things as IF offsets. An 11-digit display is sectionalized for easy readout to 1Hz resolution. SPECS: INPUT 1: Frequency Range: 500 MHz to 18 GHz* Sensitivity: 500 MHz to 12.4 GHz: 25 dBm 12.4 GHz to 18 GHz: 20 dBm*Maximum Inp
|
|
Agilent HP 5342A Microwave Frequency Counter 10hz-18Ghz W / 001 and 006 Warranty
HP 5342A Microwave Frequency Counter 10hz-18Ghz Good to-23dBm@ 18GHz Measured up to 26Ghz Opt. 001- High Stability Time Base Opt. 006 Limiter Input Protection( +39dBm) 15 Day Repair or Replace Warranty
|
|
HP /Agilent 5342A Microwave Frequency Counter. NOT WORKING PROPERLY. READ.
I have a Agilent/ Hewlett Packard 5342A 10 Hz- 18.0 GHZ Microwave Frequency Counter THAT IS NOT WORKING PROPERLY U p For Bid. The HP/Agilent 5342A Microwave Frequency Counter Covers 10 Hz to 18.0 GHZ Microwave Frequency is being sold for PARTS ONLY AS-IS. During Bench testing I found the 10 Hz- 500 MHz input working fine. But the 500- 18.0 GHZ port quits after a ~15 minute warm up. For this reason I am selling the unit: AS-IS FOR PARTS ONLY. ALSO. THERE ARE NO CABINETS ON THE UNIT SO WHAT YOU SEE IN THE PICTURE IS WHAT YOUR GOING TO GET. PLEASE VIEW ALL PICTURES AND ASK ANY QUESTIONS YOU MAY HAVE. The Serial Number is: 2428A09032. I I accept PayPal Only. Thanks for looking.
|
|
Agilent HP 5342A Microwave Frequency Counter Options 001 002 004 011 with Manual
This is a fully working example of this counter. Options include the High Stability timebase. Using in this case the-hp- 10811 oven, one of the best ever made; the input level measuring facility(Opt 002) the Option 004 Digital to Analog convertor, and the HPIB interface Option 011. I have set the OCXO against a GPS standard after 24 hours of warm up but accuracy depends slightly on the unit's final position. Included is an original paper copy of the Operating and Service Manual Part Number 05342-90013. The rear panel OCXO output is at TTL level. Per the manual, in case you were expecting a sine wave.
|
|
HP 5342A Microwave Frequency Counter w/ Opt 002 & H01 ***PARTS/REPAIR ONLY***
HP 5342A Microwave Frequency Counter w/ Opt 002& H01. This item is not functional. There are parts missing from inside the unit*SEE PICTURES* FOR PARTS OR REPAIR ONLY* THIS ITEM IS SOLD AS IS* No returns* No cables included* S/N 2317A07867 Purchased from test equipment auction. Check out our Ebay store for additional electronics. May combine shipping if purchasing two or more items. If interested in combined shipping. Please send an email prior to payment to receive a combined shipping invoice.
|
|
Agilent/HP 5342A Microwave Frequency Counter Option 011 HPIB
HP 5342A Microwave Frequency Counter Option 011 HPIB Tested and Working The 5342A Frequency Counter provides automatic frequency measurement to 18 GHz in a highly portable package. Selectable input attenuation of 50 Ohms and 1 MOhm. Two input frequency ranges: 10 Hz to 500 MHz& 500 MHz to 18 GHz. The 5342A is particularly useful in the communication field since it can tolerate an FM carrier frequency of up to 50MHz peak to peak. Because it utilizes microprocessor technology. The keyboard allows you to perform various math functions to allow for such things as IF offsets. An 11-digit display is sectionalized for easy readout to 1 Hz resolution. Specifications: Input 1: Frequency Range: 500 MHz to 18 GHz Sensitivity. 500 MHz to 12.4 GHz: 25 dBm Sensitivity. 12.4 GHz to 18 GHz: 20 dBm Dynamic Range. 500 MHz to 12.4 GHz: 22 dBm to +22 dBm ... moreDynamic Range. 12.4 GHz to 18 GHz: 15 dBm to +22 dBm Maximum Operating Level: +22 dBm Damage Level: +25 dBm. Peak Resolution: 0.1 dBm Accuracy: ±1.5 dB SWR. Amplitude Measurement: SWR. Frequency Measurement: Measurement Time: 100 ms + frequency measurement time Display: simultaneously displays frequency to 1 MHz resolution and level. Option 011 provides full frequency resolution on HP-IB Input 2(50Ω Impedance Only) Frequency Range: 10 MHz to 520 MHz Dynamic Range(Frequency and Level) 17 dBm to +20 dBm Damage Level: +24 dBm Accuracy: ±1.5 dB SWR: Measurement Time: 100 ms + frequency measurement time Display: simultaneously displays frequency and input level Option 011: Digital Input/Output(HP-IB) Operating and Service Manual: HP 5342A Microwave Frequency Counter Operating and Service Manual Payment: Paypal accepted. We DO NOT accept Personal Checks. Note: due to eBay's new policy. Sellers can no longer ask for Cashier's Checks/Money Orders via listings or emails. Contact should be made within 3 days and payment must be received within 10 days of winning. Payment must clear before shipping. Unpaid auction wins will be forfeited after 10 days and a Non-Payer repor
|
|