Ohm Standard Resistor Optics Positioner Laser Optics Bin 3 Unknown Optics Laser Optical Bin 3 Current Calibrator Calibrator Standard Pneumatic Calibrator Cable For Accelerometer Omega Calibrator Ea Optics Thermocouple Calibrator Optics Bin 4 Standard Inductor Unknown Application Calibrator 0 Piezoelectric Accelerometer Calibration Vibration Optical Bin 1 Optical Bin 3 Precision Calibrator Loop Calibrator Resistance Standard Voltage Standard Dead Weight Tester Tester Calibrator Resistance Decade Multifunction Calibrator Vintage Microscope Objective Guildline Calibrator Tested Frequency Standard Oscillator Ac Calibrator Portable Calibrator Process Calibrator Laser Optics Bin 1 Standard Capacitor Altek Calibrator Dc Calibrator Altek Model Decade Resistance Decade Resistance Box Hp Calibration Kit Ohm Resistance Standard Mil Spec Laser Optics Decade Resistor Mil Spec Laser Optical Optics Bin 3 Torque Tester Fluke Standard Esi Resistor Druck Calibrator Optics Assembly Huge Optics Dead Weight Pcb Accelerometer Fluke 5100B Transmation Pps Mm Dia Fl Optics Window Ametek Calibrator Dc Voltage Calibrator Optical Mounted Prism Laser Optics Optics Coated Lens Lens Mil Spec Laser Optics Pressure Calibration Flow Calibrator Calibrator Type Calibrator Thermometer Documenting Process Calibrator Fluke 5100B Calibrator Optics Fixture Iet Digital Calibrator Hp Calibrator Newport Optics 10-32 For Accelerometer Optics Prism Rubidium Frequency Standard Rubidium Standard Transmation Druck Dpi Optics Device Rubidium Frequency Mm Laser Optics Standard Resistor Temperature Calibrator Standard Cell Rtd Calibrator Bliley Quartz Pcb Piezotronics Piezotronics Quartz Crystal Frequency Altek Calibration Fixture Calibrator Hart Leitz Wetzlar Germany Microscope Frequency Calibrator Pure Chemical Coated Laser Optics Tektronix Calibration Calibration Model Calibrator Free Shipping Nist Calibrator Microscope Ocular Genrad Gr Gr General Radio Genrad Pressure Module Optical Prism Optics Coated Filter Rubidium Optics Glass Melles Griot Optics Voltage Calibrator Hart Scientific Torque Calibrator Thermometer Calibrator Dc Voltage Standard Programmable Calibrator Dry Calibrator Optics Lens Convex Datron Transmation Model Meter Calibrator Bliley Calibration System Torque Analyzer Filter Laser Optics Quartz Oscillator Optical Coated Optics Beam Splitter Calibrator Source Radio Genrad Vibration Sensor Verification Kit Calibrator Module Optics Micrometer Endevco Nice Optics Ametek Jofra Infrared Laser Optics Lamp Microscope Bin 11 Ea Lamp Dc Reference Standard Resonator Frequency Reference Standard Endevco Meggitt Accelerometer Accelerometer Pressure Charge Amplifier Guildline Standard Resistor- Accuracy 9330 Portable Pressure Calibrator Electro Scientific Industries Voltage Current Calibrator Calibration Standard Decade Capacitor Endevco Model Range Calibrator Ge Druck Dpi Bin Pmel Dead Weight Pressure Meter Calibration Resistance Calibrator Fluke 5700A Microscope Objective Optics Valhalla Scientific Leeds Northrup Primary Flow Calibrator Calibrator Multimeter Japan Optics Frequency Standard Calibrator Signal Resistor 100 Mirror Laser Optical Low Noise Cable Japan Microscope Beam Splitter Bliley Crystal Multifunction Process Calibrator Short Load Voltage Divider Dry Block Calibrator Mirror Laser Optics Torque Meter Nist Mirror Filter Optics Flat Calibrator Pump Transfer Standard Chip Resistor Calibration Test Datron Wavetek Analyzer Calibrator Positioner Stage Efratom Genrad Precision Decade Bin 7 Fluke Hart Scientific
 In 
 
Order by: 
Available to: 
Price: 
 - 
$
279.91
Buy It Now
Free Shipping
Condition: Used
Location: Baton Rouge,LA,USA
$
1,442.96
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
$
1,749.99
Buy It Now
Free Shipping
Condition: Used
Location: Phoenix,AZ,USA
$
599
Buy It Now
$12 Shipping
Condition: Used
Location: Madison,WI,USA
$
7,299.98
Buy It Now
$250 Shipping
Condition: Used
Location: Bloomfield,CT,USA
$
727.29
Buy It Now
Free Shipping
Condition: Used
Location: Leander,TX,USA
$
15,999.98
Buy It Now
$500 Shipping
Condition: Used
Location: Bloomfield,CT,USA
Mahr Federal Gauge Gage Block Comparator Calibrator MDL 130B-24 S/N 8050 Unit is matched serial numbers between the Comparator Gage. The Amplifier and ... morethe Analogue Readout. Designed for the calibration of gage Blocks above 4" Range: 0.010" 24" Resolution: 000001" Used for the calibration of gage blocks. Product Brochure: Product Website: Mahr Federal’s 130B-16 Gage Block Comparator is truly the preferred choice of all major calibration laboratories. It is specifically designed for the measurement of gage blocks by comparison. With no compromises made. The Model 130B-16 provides the ultimate in resolution and reproducibility for measurement of industry’s most important dimensional standards. Unique"Floating Measuring Frame" assures true point-to-point measurement. Single sensor design for the lowest possible electronic noise. Precise counterbalancing for control of measurement forces. Visit Us at www.bullseyecalibration.com. Please feel free to email with any questions that you may have. And I will do my best to try to help. Please give us a call at 860-242-4953 to discuss payment options. All shipping costs to be paid by bidder. We will not ship this unit Internationally. We do accept personal checks. Bank checks, company checks, and bank wire transfers. SHIPPING POLICY: We sell sensitive test and measurement equipment here on Ebay. We strive for 5-star service. So we invest a great deal of time and care to package all of our items safely for shipment# This attention to detail means it may take up to 10 days for us to prepare and ship your units out of our facility. We want to support you throughout the transaction and want you to be satisfied, so please to contact us at 860-242-4953 with any questions or concerns. We do out best to ship quickly, but never at the expense of quality delivery. RETURN POLICY: This unit is being sold as-is. The auction description is written as a guide. We strongly recommened that you come view and test the units at our facility. Feel free to give us a c
$
89.98
Buy It Now
$0 Shipping
Condition: Used
Location: Des Moines,IA,USA
GENERAL RADIO INEGRATOR 1933-9610 FOR VIBRATION INTEGRATION SYSTEM VINTAGE USED Description: PLEASE READ BEFORE PURCHASING ASK ALL QUESTIONS BEFORE PURCHASING ... moreTO AVOID ANY CONFUSION. Pleas contact me at 515 707 8120. Please do not use email to contact me. Ebay messages or phone only. EXACTLY what is pictured is included. If it is not pictured. Assume it is not included. IF YOU RECEIVE YOUR ITEM AND IT IS NOT TO YOUR 100 PERCENT SATISFACTION. CONTACT US BEFORE LEAVING FEEDBACK! We strive to make sure every transaction a positive one! CONDITION OF ITEM IN THIS LISTING IS:2 EXACTLY WHAT IS SHOWN IS INCLUDED. Please check out my other General Radio items I currently have for sale on Ebay. Thank you. The item condition numbers and their definitions are below: 1. NEW 2. I guarantee this item to fully work or I will send you a full refund within seven days of you receiving the item. 3. I guarantee this item to power on. I have not tested the functionality of this item. If it does not power up. I will send you a full refund. Beyond that, no refunds will be offered. 4. Unable to test due to lack of knowledge or inappropriate power source. This item is sold AS-IS with no guarantees or refunds offered. 5. Failed to power up or testing and is being sold for parts. This item is sold AS-IS with no guarantees or refunds offered
$
220
Buy It Now
Free Shipping
Condition: Used
Location: Fort Worth,TX,USA
$
515
Buy It Now
$0 Shipping
Condition: New
Location: China
$
675.18
Buy It Now
$0 Shipping
Condition: New
Location: China
$
43,789
Buy It Now
$0 Shipping
Condition: Seller refurbished
Location: Toledo,OH,USA
$
19,995
Buy It Now
$0 Shipping
Condition: Seller refurbished
Location: Toledo,OH,USA
$
382.5
Buy It Now
$70 Shipping
Condition: Used
Location: Poland
$
382.5
Buy It Now
$70 Shipping
Condition: Used
Location: Poland
$
999.99
Buy It Now
$15 Shipping
Condition: For parts or not working
Location: Chicago,IL,USA
$
285
Buy It Now
Free Shipping
Condition: Used
Location: Sunman,IN,USA
$
231.54
Buy It Now
$133.06 Shipping
Condition: New
Location: United Kingdom
Kewtech FC2000 Calibration Check Box The Kewtech FC2000 Calibration Checkbox is an affordable option that allows electricians to check their own 17th ... moreEdition test equipment and ensure that all meters are operating correctly and accurately. The Kewtech FC2000 Calibration Check Box doesn’t replace the calibration requirements of testers but provides a quick and simple way to check instrument accuracy. Reducing the risk of incorrect certification. Kewtech FC2000 Calibration Checker features ► Checks all leading makes of Loop. RCD, Insulation, Continuity and Multifunction testers. ► Regularly validate your test instruments with self calibration checks. ► 12 comprehensive test points covering Loop. RCD and Insulation/Continuity. ► Null facility to remove lead resistance.
$
82.16
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
$
1,999.99
Buy It Now
$0 Shipping
Condition: For parts or not working
Location: Neptune,NJ,USA
$
16.99
Buy It Now
$5.99 Shipping
Condition: New
Location: China
$
1,759
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
$
45.9
Buy It Now
$0 Shipping
Condition: New
Location: Hong Kong
$
5,999.98
Buy It Now
$500 Shipping
Condition: Used
Location: Bloomfield,CT,USA
$
4,162.5
Buy It Now
$0 Shipping
Condition: Used
Location: Mukilteo,WA,USA
On Products over $75) GE Druck DPI 620/G Genii Series Advanced Modular Calibrator with HART Communicator New- Factory Authorized Distributor- Factory ... moreWarranty New color scheme to reflect a unified M&C branding going forward Complete HART communicator included Optional Foundation Fieldbus communicator Modular re-rangeable and expandable concept Individual components can be used as stand-alone instruments The GE Druck DPI 620 Genii is a flexible modular calibration system that uses three basic components to perform multiple functions that formerly required a wide range of different instruments. The basic component of this system is the GE Druck DPI 620 Genii multifunction calibrator. A next-generation, ultra-compact, electrical, frequency, and temperature calibrator, which provides simultaneous measurement and source capabilities. Pressure measurement is provided by interchangeable pressure modules that can be attached to the calibrator by a pressure module carrier. Inside is a fully functional HART field communicator, replacing the need for a stand-alone HART communication unit. A Foundation Fieldbus communicator is also available as an option. If pressure generation is required, the calibrator and pressure module can be attached to one of three pressure generation stations, to form a high performance, full-integrated pressure calibrator. GE Druck DPI 620 Genii Series Advanced Modular Calibration and HART Foundation Fieldbus Communicator can measure and source mA, mV, V, Ohms, frequency, and a variety of RTDs and T/Cs. GE Druck DPI 620 Genii multifunction calibrators provide an isolated 24V loop power supply to energize devices and control loops and a stabilized DC voltage supply for ratio metric transducers. A HART digital configurator is provided for set-up and calibration adjustments of HART devices. As the next generation model, the DPI 620 Genii incorporates an advanced touch screen and new user interface for a flatter menu structure and greater ease-of-use. A completely new digital platform supports HART
$
35,195
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
Fluke Calibration 6531-140M Electronic Deadweight Tester. 140 Mpa New- Factory Authorized Distributor- Factory Warranty Pressure ranges available to 200 ... moreMPa(30.000 psi) +/ 0.02% of reading total one-year accuracy. 0.025% for two years Low torque variable volume allows for pressure generation and control up to 200 MPa(30.000 psi) with minimal physical effort Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in. 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5 The Fluke Calibration 6351 E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and manually operated pressure generation and control hardware in a single. Compact and rugged package. The Fluke Calibration 6351 E-DWT-H offers the ease of use and precision of continuous, real time electronic pressure measurement with the simple and direct pressure control of high quality manual pressure hardware. The Fluke Calibration 6351 E-DWT is named"electronic deadweight tester" because it is intended as a lightweight and easy to use, modern alternative to conventional piston-cylinder and weight based deadweight testers. FREE UPS Ground Shipping on items OVER $75 to continental U.S. PO Boxes/APOs require USPS shipping. May experience longer lead times. 6.25% Sales Tax for shipping to Massachusetts(Add an additional $24 for shipments to AK. HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands. Guam, Puerto Rico, Palau, U.S. Virgin Islands and American Samoa. Terms and Conditions Have a Question? Send us a message(Contact Seller) We are shipping from just north of Boston. MA in the United States. For international customers, do no
$
31,749
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
Fluke Calibration 6531-70M Electronic Deadweight Tester. 70Mpa/10K Psi New- Factory Authorized Distributor- Factory Warranty Pressure ranges available ... moreto 200 MPa(30.000 psi) +/ 0.02% of reading total one-year accuracy. 0.025% for two years Low torque variable volume allows for pressure generation and control up to 200 MPa(30.000 psi) with minimal physical effort Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in. 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5 The Fluke Calibration 6351 E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and manually operated pressure generation and control hardware in a single. Compact and rugged package. The Fluke Calibration 6351 E-DWT-H offers the ease of use and precision of continuous, real time electronic pressure measurement with the simple and direct pressure control of high quality manual pressure hardware. The Fluke Calibration 6351 E-DWT is named"electronic deadweight tester" because it is intended as a lightweight and easy to use, modern alternative to conventional piston-cylinder and weight based deadweight testers. FREE UPS Ground Shipping on items OVER $75 to continental U.S. PO Boxes/APOs require USPS shipping. May experience longer lead times. 6.25% Sales Tax for shipping to Massachusetts(Add an additional $24 for shipments to AK. HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands. Guam, Puerto Rico, Palau, U.S. Virgin Islands and American Samoa. Terms and Conditions Have a Question? Send us a message(Contact Seller) We are shipping from just north of Boston. MA in the United States. For international customers,
$
47,644
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
$
45,325
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
$
31,749
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
Fluke Calibration 6531-7M Electronic Deadweight Tester. 7 Mpa(1K Psi) New- Factory Authorized Distributor- Factory Warranty Pressure ranges available ... moreto 200 MPa(30.000 psi) +/ 0.02% of reading total one-year accuracy. 0.025% for two years Low torque variable volume allows for pressure generation and control up to 200 MPa(30.000 psi) with minimal physical effort Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in. 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5 The Fluke Calibration 6351 E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and manually operated pressure generation and control hardware in a single. Compact and rugged package. The Fluke Calibration 6351 E-DWT-H offers the ease of use and precision of continuous, real time electronic pressure measurement with the simple and direct pressure control of high quality manual pressure hardware. The Fluke Calibration 6351 E-DWT is named"electronic deadweight tester" because it is intended as a lightweight and easy to use, modern alternative to conventional piston-cylinder and weight based deadweight testers. FREE UPS Ground Shipping on items OVER $75 to continental U.S. PO Boxes/APOs require USPS shipping. May experience longer lead times. 6.25% Sales Tax for shipping to Massachusetts(Add an additional $24 for shipments to AK. HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands. Guam, Puerto Rico, Palau, U.S. Virgin Islands and American Samoa. Terms and Conditions Have a Question? Send us a message(Contact Seller) We are shipping from just north of Boston. MA in the United States. For international customers,
$
298.83
Buy It Now
$105 Shipping
Condition: Used
Location: Ukraine
$
650
Buy It Now
$180 Shipping
Condition: New – Open box
Location: Ukraine
$
31,749
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
Fluke Calibration 6531-20M Electronic Deadweight Tester. 20 Mpa/3K Psi New- Factory Authorized Distributor- Factory Warranty Pressure ranges available ... moreto 200 MPa(30.000 psi) +/ 0.02% of reading total one-year accuracy. 0.025% for two years Low torque variable volume allows for pressure generation and control up to 200 MPa(30.000 psi) with minimal physical effort Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in. 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5 The Fluke Calibration 6351 E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and manually operated pressure generation and control hardware in a single. Compact and rugged package. The Fluke Calibration 6351 E-DWT-H offers the ease of use and precision of continuous, real time electronic pressure measurement with the simple and direct pressure control of high quality manual pressure hardware. The Fluke Calibration 6351 E-DWT is named"electronic deadweight tester" because it is intended as a lightweight and easy to use, modern alternative to conventional piston-cylinder and weight based deadweight testers. FREE UPS Ground Shipping on items OVER $75 to continental U.S. PO Boxes/APOs require USPS shipping. May experience longer lead times. 6.25% Sales Tax for shipping to Massachusetts(Add an additional $24 for shipments to AK. HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands. Guam, Puerto Rico, Palau, U.S. Virgin Islands and American Samoa. Terms and Conditions Have a Question? Send us a message(Contact Seller) We are shipping from just north of Boston. MA in the United States. For international customers,
$
31,749
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
Fluke Calibration 6531-40M Electronic Deadweight Tester. 40 Mpa/6K Psi New- Factory Authorized Distributor- Factory Warranty Pressure ranges available ... moreto 200 MPa(30.000 psi) +/ 0.02% of reading total one-year accuracy. 0.025% for two years Low torque variable volume allows for pressure generation and control up to 200 MPa(30.000 psi) with minimal physical effort Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in. 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5 The Fluke Calibration 6351 E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and manually operated pressure generation and control hardware in a single. Compact and rugged package. The Fluke Calibration 6351 E-DWT-H offers the ease of use and precision of continuous, real time electronic pressure measurement with the simple and direct pressure control of high quality manual pressure hardware. The Fluke Calibration 6351 E-DWT is named"electronic deadweight tester" because it is intended as a lightweight and easy to use, modern alternative to conventional piston-cylinder and weight based deadweight testers. FREE UPS Ground Shipping on items OVER $75 to continental U.S. PO Boxes/APOs require USPS shipping. May experience longer lead times. 6.25% Sales Tax for shipping to Massachusetts(Add an additional $24 for shipments to AK. HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands. Guam, Puerto Rico, Palau, U.S. Virgin Islands and American Samoa. Terms and Conditions Have a Question? Send us a message(Contact Seller) We are shipping from just north of Boston. MA in the United States. For international customers,
$
31,749
Buy It Now
$0 Shipping
Condition: New
Location: Melrose,MA,USA
Fluke Calibration 6531-14M Electronic Deadweight Tester. 14 Mpa/2K Psi New- Factory Authorized Distributor- Factory Warranty Pressure ranges available ... moreto 200 MPa(30.000 psi) +/ 0.02% of reading total one-year accuracy. 0.025% for two years Low torque variable volume allows for pressure generation and control up to 200 MPa(30.000 psi) with minimal physical effort Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in. 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5 The Fluke Calibration 6351 E-DWT-H is used in the lab or instrument shop or can be taken into the field for performing in-situ calibrations and tests. This hydraulic pressure calibration system combines a high performance electronic reference pressure monitor and manually operated pressure generation and control hardware in a single. Compact and rugged package. The Fluke Calibration 6351 E-DWT-H offers the ease of use and precision of continuous, real time electronic pressure measurement with the simple and direct pressure control of high quality manual pressure hardware. The Fluke Calibration 6351 E-DWT is named"electronic deadweight tester" because it is intended as a lightweight and easy to use, modern alternative to conventional piston-cylinder and weight based deadweight testers. FREE UPS Ground Shipping on items OVER $75 to continental U.S. PO Boxes/APOs require USPS shipping. May experience longer lead times. 6.25% Sales Tax for shipping to Massachusetts(Add an additional $24 for shipments to AK. HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands. Guam, Puerto Rico, Palau, U.S. Virgin Islands and American Samoa. Terms and Conditions Have a Question? Send us a message(Contact Seller) We are shipping from just north of Boston. MA in the United States. For international customers,
$
60,000
Buy It Now
$300 Shipping
Condition: New – Open box
Location: Japan
Thanks for your interest in supporting Merit ePartners#R14380707 This listing is for a HP Agilent 5071A Primary Frequency Standard with Opt: 001. Hi Performance" ... moreThis instrument has Firmware version: 4006. It powers on and responds to inputs. The system completes an oven warm up period. The display shows a"Fatal Error See Log" We scrolled through a log and found Error Code 000038e0 00000000. We hope that the buyer can determine how to eliminate the error. This system looks very clean. It has some very light surface wear and sticker residue from prior use. The calibration seals are intact. Standard power cord is not included. We offer a 30 day money back guarantee. Your purchases help to keep us a self sustaining enterprise. Please watch Meritonlinesales for more industrial. Test and measurement, scientific, computer, telecom and networking equipment. In compliance with Merit ePartners’ environmental policy. If you are not completely happy with your purchase or have purchased a product for parts or repair, we ask that you please return any defective electronic components, batteries or materials containing potentially toxic material back to us for safe recycling. Merit ePartners will provide return postage for return of electronic waste. Shipping and Handling Information We ship to US customers only. We cannot export or ship to eBay buyers registered outside of the US or Canada. We cannot ship to export companies. We do not ship to customers registered on eBay in other countries. Or customers with international registration email addresses, even if they provide a US shipping address. Please note: We are a work training program; all packaging is done by participants of the program. Handling rates are individually determined by value. Weight, and handling time spent to properly pack auction items. For multiple items won, we will do our best to accommodate a discount where feasible. Thank you for your understanding and patronage. Please use the shipping calculator provided to determine shipping costs if
$
759
Buy It Now
$200 Shipping
Condition: Used
Location: Ukraine
402-M1 Multifunctional. Multivalued decade resistance digital box. Bridge, potentiometer, resistor. Analog of: General Radio(GenRad) LEEDS& NORTHRUP, ... moreESI, IET Labs, GR, Yokogawa, Shallcross, Tinsley& Co, Shallcross, Leeds& Northrup, L&N, Extech, EMCO, AEMC devices. But has the same or better characteristics: Digital Bridge SHCH402-M1 Is designed to measure DC resistance in the range: 0.001-1 000 000 000 000 000 Ohm. Accuracy class: 1.0/ 0.5( 0.01-0.1 Ohm) 0.5/ 0.05( 0.1-1 Ohm) 0.05/ 0.05( 1.0-10 Ohm) 0.05(10 Ohm- 50 GOhm) 0.2(50 GOhm- 1TOhm) 0.5( 1TOhm- 2TOhm) 1.0( 2TOhm- 5TOhm) 2.0( 5TOhm- 10TOhm) 5.0( 10TOhm- 20TOhm) 10.0( 20TOhm- 100TOhm) 60.0( 100TOhm- 1000TOhm) Automatic selection of measurement range. Measurementrange. Ohm Accuracy class Measured resistance power. Watt Min. Voltage on measured resistance. V Nominal Voltage on measured resistance. V 1·10-3-1·10-1 1.0/0,5 0.02 Watt 1·10-1-1.0 0.5/0,05 1.0-10 0.05/0,05 10-1·10 2 0.05/0 1·10 2-1·10 3 1·10 3-1·10 4 1·10 4-1·10 5 1·10-5-1·10 6 0.05/0 1.5 V 30±20 V 1·10 6-1·10 7 300-60 V 1·10 7-1·10 8 300-60 V 1·10 8-1·10 9 1·10 9-1·10 10 1·10 10-5·10 10 5·10 10-1·10 12 0.2/0 3.0 V 1·10 12-2·10 12 0.5/0 15 V 2·10 12-5·10 12 1.0/0 5·10 12-1·10 13 2.0/0 30 V 1·10 13-2·10 13 5.0/0 60 V 2·10 13- 1·10 14 10.0/0 270 V 300-30 V 1·10 14-1·10 15 60.0/0 The average service: at least 10 years; MTBF: not less than 8.000 hours; Resistance measurement range: 1·10-3- 1· 10 15 Ohm; Quantaty of decades: 5; Dimensions: 160 x440x400mm; Weight: 20 kg. Warranty 12mounth. Digital Bridge SHCH402-M1, designed to measure DC electrical resistance(hereinafter- resistance) in the range 1·10-3 Ohm- 1·10 4 Ohm with a use of four-meaning scheme and connection of special measuring object(hereinafter- measured resistance) with a use of connecting cable and cables connectors in ra
$
2,167
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
G79 Exact Micro Teslameter. Gaussmeter, Magnetometer analog of Alpha Lab, F.W. Bell, but has the same or better characteristics. Microteslameter G79 is ... moreused to measure the rms values of the magnetic induction from 0.02 mkT to 1000mkT alternating magnetic fields with frequency from 20Hz to 20kHz in a small volume of space. Measurement range: 0.02 mkT- 1000mkT; Measured chanels settings: 0.1mkT.0.3mkT; 1mkT; 3mkT; 10mkT; 30mkT; 100mkT;300mkT; 1000mkT; Measurement range: 20Hz- 20kHz; High Accuracy class: 5% Voltage: 220V. 50Hz or 6 built-in batteries; Power consumption: 6 V ∙ A; Weight: 6 kg. Warranty 12 months. The presence of the analog output allows to research the magnetic induction waveform and automate the processes of measurement and control with the help of connected analyzing and reproducing devices. Microteslameter G79 consists of measuring panel and two interchangeable sensors. Diameter of the probe- 13.0 mm. The length of the probes sensitive part 6.0 mm. 20.0 mm; Microteslameter can be used in the determination of magnetic compatibility at adjusting and non-destructive testing of nodes. Blocks, and elements of radio and electronic devices; In contrast to similar samples Microteslameter G79 has an extended amplitude and frequency ranges; Microteslameter G79 Power supply- 220V, 50Hz. Or from six built-in battery type 3336(or analog) The power consumed does not exceed 6V•A; The manufacturer guarantees that the quality of devices Microteslameter G79 corresponds to the technical requirements TR. If consumering the terms and conditions of storage. Transportation. Installation, operation, established by the technical conditions and operational documents. Microteslameter G79 is used to measure the rms values of the magnetic induction from 0.02 mkT to 1000mkT alternating magnetic fields with frequency from 20Hz to 20kHz in a small volume of space. This device can be connected to other devices with the use of special connector. Consists of measuring controlel and two interchangeable probes( di
$
999.68
Buy It Now
$170 Shipping
Condition: New – Open box
Location: Ukraine
Voltage comparator P3003. Analog of Lutron. Advantest. Avtech, HP Agilent. NoiseCom, General Radio. Boonton, Anritsu, Fluke and general Electric, but ... morehas the same or better characteristics. This device can be used for wide measurement range. Voltage comparator P3003 Is designed for: DC voltage comparison(relative measurement) voltage measurement(with normal element class 0.001. II level) calibrated voltage issuance; voltage increase. Accuracy class 0.0005. Voltage comparators P3003(hereinafter comparators) differential. Accuracy class 0.0005 are designed for: DC voltage comparison(relative measurement) voltage measurement(with normal element class 0.001. II level) calibrated voltage issuance; voltage increase Voltage comparator P3003 includes modes with external digital and analog output meter. Comparator operating conditions: ambient temperature- from +10 ° C to +35 ° C. Relative humidity- 80% at 25 ° C, voltage supply- 220 ± 22)V, at frequency 50, 60Hz. Voltage comparator P3003. Is designed for areas with tropical climates, corresponds to performance 0 category 4.1. And operate at temperatures from 10 ° to 35 ° C. Comparator model P3003- 04.1. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics of device inductance standard P547: Differential voltage comparator. When measuring and comparing voltages calibrator built jointly operate together. Differential instrumentation amplifier, differential micro voltmeter, input voltage divider. Compared and measurement limits calibrator compensated voltage input voltage: 11.111110 V; 1.1111110 V; 0.1
$
655
Buy It Now
$105 Shipping
Condition: New – Open box
Location: Ukraine
$
830
Buy It Now
$130 Shipping
Condition: Used
Location: Ukraine
P310 or P321 or P331 Coil. Unevalued resistance standard resistor. SET of 9psc. 30% discount. P310 or P321 or P331 resistance standard resistor analog ... moreof LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 0.001- 0.01- 0.1- 1- 10- 100- 1000- 10000- 100000 Ohm. Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 0.001 P310 100 20 20 5 20 5 0.1 0.05 32 1000 0.01 P310 100 20 20 5 20 5 0.1 0.05 10 1000 0.1 P321 100 15 20 3 20 4 0.1 0.05 3.2 1000 1 P321 100 15 20 3 20 4 0.1 0.05 1 1000 10 P321 100 15 20 3 20 4 0.1 0.05 0.32 1000 100 P331 100 8 20 2 20 10 0.1 0.025 0.1 1000 1000 P331 100 8 20 2 20 10 0.1 0.025 0.032 1000 10000 P331 100 8 20 2 20 10 0.1 0.025 0.01 5000 100000 P331 100 8 20 2 20 10 0.1 0.025 0.0032 50000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) Warranty: 12 month. Electrical resistance coil Represents an exemplary resist ance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Accuracy class 0.01 Electrical resistance coil represents an exemplary resistance standard and is designed for testing and fitting working r
$
944.74
Buy It Now
$130 Shipping
Condition: New – Open box
Location: Ukraine
P310 or P321 or P331 Coil. Unevalued resistance standard resistor. SET of 9psc. 30% discount. P310 or P321 or P331 resistance standard resistor analog ... moreof LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 0.001- 0.01- 0.1- 1- 10- 100- 1000- 10000- 100000 Ohm. Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 0.001 P310 100 20 20 5 20 5 0.1 0.05 32 1000 0.01 P310 100 20 20 5 20 5 0.1 0.05 10 1000 0.1 P321 100 15 20 3 20 4 0.1 0.05 3.2 1000 1 P321 100 15 20 3 20 4 0.1 0.05 1 1000 10 P321 100 15 20 3 20 4 0.1 0.05 0.32 1000 100 P331 100 8 20 2 20 10 0.1 0.025 0.1 1000 1000 P331 100 8 20 2 20 10 0.1 0.025 0.032 1000 10000 P331 100 8 20 2 20 10 0.1 0.025 0.01 5000 100000 P331 100 8 20 2 20 10 0.1 0.025 0.0032 50000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) Warranty: 12 month. Electrical resistance coil Represents an exemplary resist ance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Accuracy class 0.01 Electrical resistance coil represents an exemplary resistance standard and is designed for testing and fitting working r
$
583.99
Buy It Now
$85 Shipping
Condition: New – Open box
Location: Ukraine
P534/3 Variable Capacitor 0.5pF-152pF 0.5% Analog of Jennings. General Radio(GR. Genrad) IET Labs but has the same or better characteristics. Technical ... morecharacteristics: Measurement range: 0.5pF-152pF Accuracy: 0.5% Weight: 5kg Warranty 12 month. This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: Used. An old stock. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics: Temperature +10 +35 ° C; Relative humidity up to 80% This device can be also named as: P-594/3. P 594/3, P 594/3, R 594/3, R 594/3, R- 594/3. Р 594/3, р- 594/3, Р 594/3, capacitor standard. Capacitors standard. Standard capacitance. Laboratory standard, high precision capacitor. Etalon capacitor. Photos If necessary we can take photos of a device from various angles. Technical Documentation In case you didn't find in technical specifications for the device all necessary information you are interested in. Feel free to contact me. I will look through the technical documentation for the device and I will be happy to consult you. Also I may speak directly with the manufacturer and find out more specific information about this product. If some technical parameters for the device(error. Accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time. On delivering the device. Electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be doc
$
2,999.46
Buy It Now
$999.99 Shipping
Condition: New – Open box
Location: Ukraine
High precision capacitance AC bridge P5026(Set) Multivalued. High-frequency decade capacitance box capacitor standard. AC bridge analog of General Radio(GR. ... moreGenRad) IET Labs, but has the same or better characteristics. AC bridge Р5026М is designed to measure capacitance and dielectric tangent loss of high-voltage industrial insulation for a"direct" both outputs of the measuring object isolated from the"earth" and" inverted" one output of the measured object is connected to"earth" schemes under operational conditions. Directly on the installation location, as well as measurements of"direct" scheme in the laboratory capacity and dielectric tangent loss of various insulating materials and condensers at 50 and 60Hz. P5026 Set includes: 1. P5026 AC bridge- 1psc. 2. Q5122 potential protector- 1set. 3. P5069 condenser block- 1psc. 4. P5023 Standart air condenser- 1 set. 5. Solid dielectrics testing electrodes- 1 set. 6. Power cord- 1psc. 7. Cables- 1 psc. 8. Manual and docs. Technical characteristics: M easurement range С х tgδ х 10 pF-1000 pF 1∙10-4-0.1 100 pF-10000 pF 1∙10-4-1.0 10 4 pF-2∙10 4 pF 2∙10 4 pF-10 5 pF 10 5 pF-10 6 pF 5∙10-4-1.0 100 pF-10000 pF 5∙10-3-1.0(10 4 pF-10 5 pF)10 5 pF-10 6 pF) 650 pF-2∙10 5 pF 5∙10-3-0.1 6500 pF-2∙10 6 pF 5∙10-3-1.0 2∙10 6 pF-5∙10 8 pF Measurement range Operating voltage Measurement schem e С х tgδ х 10 pF-1000 pF 1∙10-4-0.1 5 kV-10 kV« straight» with F 5122 and Р5069 100 pF-10000 pF 1∙10-4-1.0 3 kV-10 kV 10 4 pF-2∙10 4 pF 2∙10 4 pF 10 5 п pF 3 kV-5 kV« straight» with F 5122 10 5 pF-10 6 pF 5∙10-4-1.0 100 pF-10000 pF 5∙10-3- 1.0 3 kV-10 kV« straight» with« turned back» 10 4 pF-10 5 pF)10 5 pF-10 6 pF) 650 pF 2∙10 5 pF 5∙10-3- 0.1 0.1 kV« straight» 6500 pF-2∙10 6 pF 5∙10-3-1.0 2∙10 6 pF-5∙10 8 pF MTBF not less than: 5250 hours; The average service at least: 6 years; Dimensions: 540 x 280 x 380mm; Weight: 22kg. Warranty 12 month. AC Bridge Р5026М consists of the following components
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5108 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5109 10 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5109 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 10 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
1,255.23
Buy It Now
$200 Shipping
Condition: New – Open box
Location: Ukraine
High Precision B1-16 AC Voltmeters programable Calibrator. Verificator, Tester analog of FLUKE,EDC,Agilent,Tektronix IET Labs. But has the same or better ... morecharacteristics. B1-16 is designed for white range AC Voltmeters calibration. Thechnical characteristics: Accuracy class: 2% Output Voltage 100mkV-3V; Output Voltage ranges: 0.316V-0.4V-0.5V-0.6V-0.7V-0.8V-0.9V-1V-1.5V-2V-2.5V-3V. Output Frequency rance: 10Hz- 50MHz; With fixed values: ​​ 10-20-30-40-45-55-100-200-300-400-450-550 Hz 1-2-3-4-4.5-5,5 10-20-30-40-45-100-200-500 kHz. 1-3-5-10-15-20-30-50 MHz. Output frequency and voltage controll type: remote or manual; Output resistance: 1-30-50 Ohm; Setlling time: less than 15 sec. Dimensions: 488x173x475mm; Weight: 20kg Warranty 12 month. This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: NEW(not used. But from an old stock) Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance clibrators, standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Device for В1-16 voltmeters verification d esigned for AC voltmeters testing in a wide frequency range. Output voltage range 100mkV- 3V with nominal rms values ​​corresponds to 0.316V-0.4V-0.5V-0.6V-0.7V-0.8V-0.9V-1V-1.5V-2V-2.5V-3V. Frequency range of output voltage 10 Hz-50 MHz with fixed values 10-20-30-40-45-55-100-200-300-400-450-550 Hz, 1-2-3-4-4.5 10-20-30-40-45-100-200-500-5.5 kHz. 1-3-5-10-15-20-30-50 MHz. Device В1-16 for voltmeters verification is designed for AC voltmeters testing in a wide frequency range. Devices В1-16 for voltmeters verification have remote and manual fixed frequency selection and nominal value of output voltage level and output to digital code on CPY. Can be used in automated calibration sys
$
2,150
Buy It Now
$140 Shipping
Condition: New – Open box
Location: Ukraine
P3027-1 Decade Voltage Devider. Dekavider analog of Fluke,HP,General Radio,EMCO,ESI. Shalltronix, Reliance Electric, Agilent, Boonton Electronics, Tektronix, ... morebut has the same or better characteristics. High precision DC Voltage Divider P3027-1 Designed to expand the limits of measurements of electrical devices in DC. And for testing voltage dividers. Division coefficient Nominal input voltage. V Input resistance. KOhm divider circuit protection circuit general 10 10 V 10±0.03 55.4±0,5 8.47±0,05 100 100 V 100±0.3 554±5 84.7±0,5 1000 1000 V 1000±3 5540±50 847±5 Division coefficient 10- Nominal input voltage: 10V; Division coefficient 100- Nominal input voltage: 100V; Division coefficient 1000- Nominal input voltage: 1000V; Power: 220±22) V; Frequency: 50-60HZ; Power consumption: 30A*V; High Accuracy class: 0.0002% Max Voltage 3kV; The average service: at least 10 years. Dimensions: 440x160x460 mm; Weight: 11 kg. Warranty 12 Months. Technical characteristic: The voltage divider P3027-1. Is designed for operation under the conditions shown in Table1. Nominal values of the coefficients of division and the corresponding values of the input resistance and input voltage corresponds to those indicated in the Table2. Value of the output resistance of the divider for all of the coefficients- 1000 ± 3) ohm. DC voltage divider P3027/1 has a special option of offline verification and adjustment of the division coefficients. The main measuring resistance of VD are placed in the active thermostat. Time required to establish the temperature in the thermostat does not exceed 2 hours. Duration of continuous operation of VD is not less than 8 hours. Not including time of the operating mode establishment. Acceptable basic error P3027-1. Is shown in percentage of the nominal values of division coefficient and in working mode is equal ± 0.0002% Inspection and adjustment of the division coefficients must be held each 2 days in order to provide accuracy in normal condition. Admi
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5105 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5105 100mkH 0.025 0.05 0.1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5105 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 100 mkH Accuracy class 0.05 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal wavefor
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5114 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5114 500 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5114 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 500 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform
$
649.99
Buy It Now
$135 Shipping
Condition: Used
Location: Ukraine
P597/7 Exemplary capacitor standard capacitance 100 0 pF General Radio.GenRad, IET analog of General Radio(GR. Genrad) IET Labs, Arco but has the same ... moreor better characteristics: Model Value Accuracy class Accuracyevaluationcapacity. Frequency range. Hz The value of loss tangent Height. Mm Diameter. Mm Weight. Kg P597/7 1000 pF 0.05 ± 0, 0 2 40-100000 5·10-5 260 180 11 Warranty 12 month. If you need such New item(not used) Please contact me, I will get it for your request. Please mind, that it may take some additional time) This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: Used. An old stock. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics: P597/1-9 is designed to be used as the exemplary steps in the chains of alternating current with a frequency from 40 to 100.000 Hz. Temperature +10 +35 ° C; Relative humidity up to 80% This device can be also named as: P-597. P-597, P 597, R597. R 597 R-597, р 597. Р- 597. Р 597 capacitor standard. Capacitors standard. Standard capacitance. Laboratory standard, high precision capacitor. Etalon capacitor. Photos If necessary we can take photos of a device from various angles. Technical Documentation In case you didn't find in technical specifications for the device all necessary information you are interested in. Feel free to contact me. I will look through the technical documentation for the device and I will be happy to consult you. Also I may speak directly with the manufacturer and find out more specific information about this product. If some technical parameters for the device(error. Accuracy, measuring range, operating voltage and fre
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5107 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5107 1 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5107 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
3,933
Buy It Now
$175 Shipping
Condition: New – Open box
Location: Ukraine
P5083 Multifunctional. Multivalued decade resistance box. Bridge, resistor. Potentiometer analog of: General Radio(GenRad) LEEDS& NORTHRUP, ESI, IET ... moreLabs, GR, Yokogawa, Shallcross, Tinsley& Co, Shallcross, Leeds& Northrup, L&N, Extech, EMCO, AEMC devices. But has the same or better characteristics: AC Bridge P5083 is an autonomous measuring device for general industrial purposes and designed for automatic measurements of: capacitance C. Inductance L. Active resistance R. Tangent loss tgδ( Q Qr) tangent angle of phase shift tgφ( Q Qc and QL) of measuremed objects. And also a percentage deviation of measured object with further presentation of measurement results in digital form. AC bridge P5083 can be used for: Scientific researches; Metrological measuring instruments attestation; Quality control of electrical and radiotechnical products; Nonelectrical values measurement with a use of nonelectrical values transformers into one of measured values. Min. Value of accuracy class: With an external model of calibration) 0.02/0,002(0.005/0,0002) The range of measured values ​​: resistance. Ohm from 1·10-5 to 1·10 10 capacitance from 1·10-16 to 10 inductance from 1·10-10 to 1·10 7 angle shift tangent(tg φ) from ± 1·10-5 to ± 1·10 +5 deviation percentage. from ± 0.001 to ± 100 frequency.KHz(3000 discrete frequencies installed) from 0.1 to 100 Discrete digital frame(on low range of measurements) active resistance. Ohm 1·10-5 capacitance 1·10-16 inductance 1·10-10 AC range of values. On-site measurements(dependingon the measuredvalues​​) V. From 0.01 to 30 Dimensions: 440 x158x405mm; Weight: 16 kg. Warranty 12mounth. Technical characteristics of AC bridge P5083: D epending on frequency and voltage of measurement object. Values measured by the AC bridge correspond to those shown in Table 1; Table1 Main Additional main derivative C Cp Rp tgδ c(Q R) Cs Rs L Lp Rp tgδ L(Q R) Ls Rs R Rp Cp tgδ c(Q C) Lp tgδ L(Q L) Rs Cs tgδ c(Q C) Ls tgδ L(Q L)
$
595.99
Buy It Now
$190 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
614.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5108 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5108 5 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5108 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 5 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
209
Buy It Now
$35 Shipping
Condition: New – Open box
Location: Ukraine
MMB( Charles Wheatstone Bridge) multivalued resistance indicator.Box,bridge resistor analog of: General Radio(GenRad) LEEDS& NORTHRUP, ESI, IET Labs, ... moreGR, Yokogawa, Shallcross, Tinsley& Co, Shallcross, Leeds& Northrup, L&N, Extech, EMCO, AEMC devices. But has the same or better characteristics: Measuring range: 0.05- 50.000 ohms. from 0.05 ohms to 5 ohms; from 0.5 ohms to 50 ohms; from 5 ohms to 500 ohms; from 50 ohms to 5000 ohms; from 500 ohms to 50.000 ohms; Accuracy class: ±2.0% ±5,0% ±15,0% Dimensions: 201 x111x65mm; Weight: 1.1 kg. Warranty 12month. Resistance Indicator ММВ(small Wheatstone bridge. Mmb) Designed for technical DC resistance measurements of the first kind conductors. Measurement range: from 0.05 Ohm to 5 Ohm; from 0.5 Ohm to 50 Ohm; from 5 Ohm to 500 Ohm; from 50 Ohm to 5000 Ohm; from 500 Ohm to 50000 Ohm Indications error depending on the range: is less than ± 2.0% ± 5.0% ± 15.0% Resistance Indicator ММВ is designed for technical DC resistance measurements of the first kind conductors. Resistance Indicator ММВ is designed to be operated at an ambient temperature of +10 to +35 ° C and relative humidity up to 80% at +30 ° C. Technical characteristics Indicator has five measurement limits: from 0.05 Ohm to 5 Ohm; from 0.5 Ohm to 50 Ohm; from 5 Ohm to 500 Ohm; from 50 Ohm to 5000 Ohm; from 500 Ohm to 50000 Ohm; Indicators MMB measurement error at average level"5" rheochords scale does not exceed ± 2.0% and on its both sides of levels"2" and"20" does not exceed ± 5.0% from actual value of measured resistance at following switch positions" x1" x10" x100" In other cases error does not exceed ± 15% In switch multiplicity" x0. 1" on levels" 0.5" and"1" error is not specified. Settling time of galvanometers moving part is not more than 4 seconds. Operating position- horizontal. Indicators MMB dimensions are not more than 201x111x65 mm. Indicators MMB wei
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5103 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5103 10mkH 0.066 0.1 0.1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5103 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 10mkH Accuracy class 0.2 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal wavefo
$
398.83
Buy It Now
$105 Shipping
Condition: Used
Location: Ukraine
$
333.99
Buy It Now
$85 Shipping
Condition: Used
Location: Ukraine
P597/3 Exemplary capacitor standard capacitance 10 0 pF General Radio.GenRad, IET analog of General Radio(GR. Genrad) IET Labs, Arco but has the same ... moreor better characteristics: Model Value Accuracy class Accuracyevaluationcapacity. Frequency range. Hz The value of loss tangent Height. Mm Diameter. Mm Weight. Kg P597/2 100 pF 0.05 ± 0, 0 2 40-100000 5·10-5 165 180 5 Warranty 12 month. If you need such New item(not used) Please contact me, I will get it for your request. Please mind, that it may take some additional time) This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: Used. An old stock. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Capacitance standard Р597 designed to be used as standard or AC circuits measurement element. Capacitance standard Р597 designed to be used as exemplary standard in AC circuits with the frequency from 40 to 100.000 Hz. Capacitance standard Р597 is used at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 30 ° C) In terms to mechanical stress Capacitance standard Р597 applies to ordinary devices. The nominal values of capacity are listed by groups in the table. The deviation of the actual capacitance(in percent of nominal value) at a frequency of 1000 Hz does not exceed ±(0.05 + Δ/ C) for C = 1 ÷ 4000pF. A = ± 0.1% determined from the capacitance values) for C = 0.01 ÷ 1mkF. Dielectric tangent loss at a frequency of 1000 Hz is less than 5• 10-5- for C = 1 ÷ 4000pF and 1• 10-3- for C = 0.01 ÷ 1.0 mkF. Capacitance value changes at the frequency deviation of 1000 Hz does not exceed ±(0.05 + 0.5/ C) for C- 1
$
550
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
$
520
Buy It Now
$155 Shipping
Condition: New – Open box
Location: Ukraine
P567 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics: ... moreNominal frequency range: 20- 5000 Hz; for decade x10: 20- 2500Hz; Extended frequency range: 5000- 10000 Hz; Accuracy class: 0.2% quantaty of decades: 10; Limits of inductance measurement: up to 111.1 mH; Max Current: 0.25A; Nominal Current: 0.2A; Dimensions: 405x215x235mm Weight: 11kg; Warranty 12 mounths This device was also used in USSR and Russia army. So it has best quality. Longevity and permanence characteristic. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Inductance box P567(Р-567. Р 567, p567, p 567, p-567) Designed to be used as inductance standard in AC measuring circuits at a frequency range from 20 Hz to 10000 Hz if all decades are connected. Except"x10" decade, which is designed for operation at frequencies up to 2500 Hz. Accuracy class 0.2 Inductance boxes P567 such as MICP are designed to be used as inductance standards in AC measuring circuits at a frequency range from 20 Hz to 10000 Hz if all decades are connected. Except"x10" decade, which is designed for operation at frequencies up to 2500 Hz. Devices are available in two versions: Inductance box P567- for work in closed rooms at an ambient temperature of +10 to +35 ° C and relative humidity of 30 to 80% Inductance box P567T– is designed for work in closed rooms at tropical climate. Technical characteristics Parameters Parameters and characteristics value Note Accuracy class of the box, according to GOST 10770-84 0.2 Nominal frequency range f
1 2
 In 

Past Items  
 
BRUEL KJAER 4221 HIGH PRESSURE MICROPHONE CALIBRATOR ACOUSTIC VIBRATION Sold as is. Only item as picture is included. No accessories, cables, etc. Thanks. TERMS OF USE Welcome to our SILO Ebay store. Please. Review our terms and conditions, which has the purpose to clarify and help for a better business relationship with our costumers. If you do not agree with any part of our company policies, please do not do any bidding in our items. IF YOU PLACE A BID IN OUR ITEMS We’ll consider that you have agreed to all the following Term of Use. ITEM CONDITIONS: Please. Make a thoroughly inspection of the photos, description and conditions of each item you are interested, before placing your bid. SILO attempts to be as accurate as possible. However. SILO does not warrant that product descriptions or other content is accurate, complete, reliable, current, ... moreor error-free. If a product offered in our store is not as described, your sole remedy is to return it in the same condition. DISCLAIMER Many of our items are previously USED products or REFURSBISHED. Therefore they are sold“with all faults” or“AS IS” unless otherwise specify in writing. The condition of the item is provided in the“ description” RETURN POLICY: Our goal is to provide our customer with the best option for their needs. If you need to return an item these rules will apply: We offer the buyer a two weeks(14 days) right to return the item. The buyer will be responsible for the cost of packing and shipping the item. Items MUST BE returned for any Refund. We do not offer partial refunds. Refunds will be given as money back. Items sold with any discount from the original price CAN NOT be returned. The sale is final. WARRANTIES OR RETURNS: NO WARRANTIES ARE EXPRESS OR IMPLIED. Items that are supposed to be operational according to the description in the listing can be returned if they are D.O.D. Items that are untested or are sold‘AS IS’ and can not be returned. DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY: All ITEMS OR PRODUCTS LISTED IN OUR EBAY
PCB PIEZOTRONICS 336C34 ACCELEROMETER VIBRATION CALIBRATOR Sold as is. Thanks. TERMS OF USE Welcome to our SILO Ebay store. Please. Review our terms and conditions, which has the purpose to clarify and help for a better business relationship with our costumers. If you do not agree with any part of our company policies, please do not do any bidding in our items. IF YOU PLACE A BID IN OUR ITEMS We’ll consider that you have agreed to all the following Term of Use. ITEM CONDITIONS: Please. Make a thoroughly inspection of the photos, description and conditions of each item you are interested, before placing your bid. SILO attempts to be as accurate as possible. However. SILO does not warrant that product descriptions or other content is accurate, complete, reliable, current, or error-free. If a product offered in our store is not as described, ... moreyour sole remedy is to return it in the same condition. DISCLAIMER Many of our items are previously USED products or REFURSBISHED. Therefore they are sold“with all faults” or“AS IS” unless otherwise specify in writing. The condition of the item is provided in the“ description” RETURN POLICY: Our goal is to provide our customer with the best option for their needs. If you need to return an item these rules will apply: We offer the buyer a two weeks(14 days) right to return the item. The buyer will be responsible for the cost of packing and shipping the item. Items MUST BE returned for any Refund. We do not offer partial refunds. Refunds will be given as money back. Items sold with any discount from the original price CAN NOT be returned. The sale is final. WARRANTIES OR RETURNS: NO WARRANTIES ARE EXPRESS OR IMPLIED. Items that are supposed to be operational according to the description in the listing can be returned if they are D.O.D. Items that are untested or are sold‘AS IS’ and can not be returned. DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY: All ITEMS OR PRODUCTS LISTED IN OUR EBAY STORE ARE PROVIDED BY SILO ON AN"AS IS" AND"AS AVAILABLE" BASIS. U
The David W. Taylor Model Basin. The TMB Portable Calibrator for Vibration Transducers by Francis F. Vane Navy Department Report 909/ November 1954. In very nice condition. Free domestic USPS First Class Mail. International shipping $ 12.00
Up for auction is a KISTLER 541T CALIBRATOR for ACCELEROMETER VIBRATION in great working condition. Free shipping!
Dactron Laser Shaker Control System Front End Box This unit came from the merge of Western Digital and Seagate and looks like it's used surplus. This unit shows recent calibration of 10/6/2011 and due 10/6/2012. Tested to power on only. Assumed to be in excellent. Used condition, but sold as is. Terms of Sale Buyer pays $28 shipping. continental US) HI. AK, PR and Canada pay $58 shipping. Paypal usually ships within 24 hours. International bidders(non-Canadian) PLEASE contact us before bidding. Thanks for your interest. Please email with any questions.
TESTING& COSMETIC NOTES: This is a USED WORKING item in VERY GOOD cosmetic condition that IS THOROUGHLY TESTED and is GUARANTEED WORKING The user can touch the metal screw part to feel the vibration. Please note that the unit may need to be calibrated prior to use. COMPONENTS INCLUDED IN THIS AUCTION: 1- MMF VC110 ACCELEROMETER VIBRATION CALIBRATOR SHAKER 70HZ-10KHZ• 1- CASE• 1- POWER SUPPLY• 1- BOX OF SCREW ADAPTERS• 1- POWER CORD• 1- INSTRUCTION MANUAL• 1- ACCELEROMETER SCREW REPLACEMENT or MONEY BACK GUARANTEE: When you receive a Guaranteed item from OC Depot. It should perform as described. In the rare situation that this is not the case, we will send a replacement upon safe return of the original item within 14 days of receiving the item. If a replacement is not available we will honor the terms of our Money-Back Guarantee. Please ... moreClick Here and Read Our Sales Policies at" at" src="http:ocdepot.com/template/Rounded_Middle_Right.gif" at" src="http:ocdepot.com/template/Rounded_Left_Bottom.gif" at" at" src="http:ocdepot.com/template/Rounded_Middle_Bottom.gif" at" src="http:ocdepot.com/template/Rounded_Right_Bottom.gif" SearchBy9- 54671 | Location: Z58 | Lister: Tommy | Tester: TESTER NAME HERE' | Tech: | Quan: 1 | List: 1 | Duplicate: False | Plan: Q1 5 pounds or more | Amazon: Size: 0x0x0 Weight: 14 | Start: $299.99 | BIN: $0.00 | Type: Auction | $hippingBump: $0 | Date: 10/25/2013 | Condition: | CONSIGNOR VIDE O | RESEARCH LINK | Created: 10/25/2013 | Business& Industrial Electrical& Test Equipment Test Equipment Calibrators Powered by
General Radio 1557-A Vibration Calibrator: Instruction Manual w/ Schematics Manuals in good used condition. 14 day right of return. General description: General Radio 1557-A Vibration Calibrator: Instruction Manual w/ Schematics-56441 We have in stock over 70.000 manuals for test equipment. If you don't find what you need, please give us a call. For questions or additional information. Please contact our Customer Service department at: 1-800-527-4642. Items may be listed on multiple sites. Availability is subject to prior sale. Warranty: 30days Return Right: 14day Payment Options We accept: PayPal(preferred) Major Credit Cards(additional Information may be required) Texas residents Only: Sales tax will be charged(Please contact Tucker Electronics at 1-800-527-4642 before making payment) Shipping Information We ship via Fed Ex or USPS. ... moreApprox Weight: 1 lb. Boxed Dim: 15x12 Envelope. INTERNATIONAL BUYERS: USPS INTERNATIONAL FIRST CLASS MAIL CAN TAKE FROM 4 TO 5 WEEKS FOR DELIVERY. LIMITED TRACKING AVAILABLE AFTER IT LEAVES TEXAS UNTIL IT ARRIVES AT DESTINATION. DO NOT ORDER BY THIS METHOD IF YOU EXPECT DELIVERY IN 5-10 DAYS. YOU NEED TO ORDER BY USPS PRIORITY MAIL WHICH IS CONSIDERABLY MORE EXPENSIVE. BUT QUICKER. E-MAIL US IF YOU HAVE A QUESTION OR NEED A QUOTE ON PRIORITY MAIL. Auction Sales Policy We will contact the winning bidder via e-mail with 2 business days after the auction has ended. Winning bidders must confirm their order within 3 business days after notification. Additional instructions for completion of sale will be included in the e-mail notification. Payment must be received within 7 business days after the order is confirmed. Or the winning bid will automatically be voided. Exceptions to this rule will be made on an individual basis. Please contact us within 3 business days if you need special arrangements. Tucker Electronics phone: 1-800-527-4642) Any and all state and local sales. Use, excise, privilege, and similar taxes imposed on TUCKER or which TUCKER has a duty to collect in con
Description General Radio 1557A Vibration Calibrator This calibrator provides a single-frequency(100 Hz) Single-level(1 g) check on the GR Vibration Pickups or any pickup whose total mass is 300 grams or less. It can provide on-the-spot calibration of vibration-measuring systems immediately before and after important measurements and can also be used to compare transducers or to calibrate working transducers against a standard transducer. Operation of the calibrator is simple. A pickup of known mass is attached to the shaker, either in place of one of the removable 50-gram disks or to one of the disks by double-faced, pressure-sensitive tape. The user adjusts the Level control until the panel meter, calibrated in grams, indicates the mass of the pickup. The pickup will then be automatically subjected to an acceleration of 1 gram at 100Hz. ... moreThe 1557-A is a small, battery-operated unit consisting of a transistorized electromechanical oscillator and a cylindrical shaker. The acceleration output of the calibrator appears at two pill box-shaped, 50-gram disks mounted on an internal cylinder that projects through the sides of the instrument. SPECIFICATIONS Output: ACCELERATION: 1 grms ±10% 1 g =386 in.s2(9.81 m/s2) VELOCITY: 0.614 in.ls(15.6 mm/s) rms. DISPLACEMENT: 0.000978 in. 0.0248 mm) rms: 0.00277 in. 0.0704 mm) pk-pk. FREQUENCY: 100 Hz+ 1% for 50- gram load; 100 Hz+ o. 2% for 300-gram load. Power: Battery operated(Eveready 724 or equivalent dry cell) Mechanical: Aluminum case. DIMENSIONS(w x h x d) 4 x 8 x 4 in. 105x205x105 mm) WEIGHT: 3.25 l b(1.5 kg) Net The item is in good condition and working. Battery is not included No accessories. Cables or power cords are included unless shown in the photos or mentioned in the description. Shipping Weight(lbs. 6 Shipping Dimensions(in. 14 x 10 x 6
For auction is a General Radio GenRad 1557-A Vibration Calibrator. These are exceptionally rare. It comes with*both* of its hard to find weights. It is used. Has plenty of gooey sticker schmutz that needs to be cleaned off and has a small piece broken from the thin plastic meter cover but the calibrator works. I do not have the 6V battery required to power it but I hooked it up to a benchtop power supply. It has been tested at 6V. The battery function works and the vibration setting works at all power levels. There is no corrosion in the battery compartment. Please look at the pictures carefully. Note: Please ask questions before the last day of the auction I ship to confirmed addresses only Item will be packed carefully This a 30 year old item. It is being sold As-Is. No returns unless it has been grossly misrepresented.
Sold as is as I do not know how to test these equipments. Payment: Ø ONLY Accepting verified PayPal Payment. Shipping: Shipping to the US ONLY. All orders are shipped via USPS priority service. Due to shipper restrictions. I can only deliver to street addresses. NO APO/FPO addresses. Orders will be processed 3 business days after receipt of valid payment information. Estimated delivery time for Ground Shipment is 3-7 business days from the date of shipment. Buyer pays 0 USD shipping. Handling and insurance. Terms& Conditions: All products being sold are used. Unless otherwise stated. Payment must be made in full within 4 days from the date of purchase. Buyer is responsible for all shipping costs including insurance. Thank you for looking.
For parts or repair KISTLER 541T CALIBRATOR for ACCELEROMETER VIBRATION Sold as is. Thanks. TERMS OF USE Welcome to our SILO Ebay store. Please. Review our terms and conditions, which has the purpose to clarify and help for a better business relationship with our costumers. If you do not agree with any part of our company policies, please do not do any bidding in our items. IF YOU PLACE A BID IN OUR ITEMS We’ll consider that you have agreed to all the following Term of Use. ITEM CONDITIONS: Please. Make a thoroughly inspection of the photos, description and conditions of each item you are interested, before placing your bid. SILO attempts to be as accurate as possible. However. SILO does not warrant that product descriptions or other content is accurate, complete, reliable, current, or error-free. If a product offered in our store is not ... moreas described, your sole remedy is to return it in the same condition. DISCLAIMER Many of our items are previously USED products or REFURSBISHED. Therefore they are sold“with all faults” or“AS IS” unless otherwise specify in writing. The condition of the item is provided in the“ description” RETURN POLICY: Our goal is to provide our customer with the best option for their needs. If you need to return an item these rules will apply: We offer the buyer a two weeks(14 days) right to return the item. The buyer will be responsible for the cost of packing and shipping the item. Items MUST BE returned for any Refund. We do not offer partial refunds. Refunds will be given as money back. Items sold with any discount from the original price CAN NOT be returned. The sale is final. WARRANTIES OR RETURNS: NO WARRANTIES ARE EXPRESS OR IMPLIED. Items that are supposed to be operational according to the description in the listing can be returned if they are D.O.D. Items that are untested or are sold‘AS IS’ and can not be returned. DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY: All ITEMS OR PRODUCTS LISTED IN OUR EBAY STORE ARE PROVIDED BY SILO ON AN"AS IS" AND"AS AVAILABLE&q
1-567-221-0615 Home Lab Equipment Analytical Equipment Pumps Analytical Instruments Spectrophotometers Autoclaves/Sterilizers Balances Biotech/ Life Sciences DNA Synthesizers Imaging Systems Micropipette Fabrication Microplate Readers Microplate Washers/ Handlers Centrifuges Clinical Laboratory Blood/Gas Analyzers Chemistry Analyzers(Clinical) Clinical Lab- Misc. Diagnostic Instruments Hematology Analyzers Controllers Detectors Gas Chromatography Generators Glove Boxes/Isolation Chambers Histology/ Pathology Cryostats Microtomes Slide Stainers Tissue Processors Homogenizers Liquid Chromatography Liquid Handling Mixers/Grinders/Homogenization Ovens Sample Preparation Ultrasonic Dryers Heaters. Baths& Circulators Lab Supplies Power Supplies Scales Other Microscopes Medical Equipment Diagnostic Equipment Imaging Equipment Medical- General ... moreOptometry Equipment Surgical- General Item Information. GRAS 42AB Class 1 Sound Calibrator Kit- G.R.A.S. 42 AB Vibration SKU: 1160645829 Condition: Used Warranty: 30-Day Warranty Description. GRAS 42AB Class 1 Sound Calibrator Kit- G.R.A.S. 42 AB Vibration. This sound calibration kit appears to be in good condition. It powered on without issue. What is displayed in the pictures is what you will receive unless otherwise specified. Please contact us if you have any questions regarding this item or if you would like us to send more pictures of it. In addition. We are willing to perform whatever tests or examinations you may request in order to better determine the condition of the unit. Simply contact us with detailed instructions. Warranty. If you are unsatisfied with your purchase or buying experience in any way. Please contact us first so we can rectify the situation before submitting feedback. We'll do whatever it takes to make things right! M-F. 8am to 6pm EST Toll Free: 1-567-221-0615 Many online sellers are there to"sell and forget. At New Life Scientific. Customer service is central. Not just something we do on the side if we have to. And although in many cases w