Ohm Standard Resistor Optics Positioner Laser Optics Bin 3 Unknown Optics Laser Optical Bin 3 Current Calibrator Calibrator Standard Pneumatic Calibrator Cable For Accelerometer Omega Calibrator Ea Optics Thermocouple Calibrator Optics Bin 4 Standard Inductor Unknown Application Calibrator 0 Piezoelectric Accelerometer Calibration Vibration Optical Bin 1 Optical Bin 3 Precision Calibrator Loop Calibrator Resistance Standard Voltage Standard Dead Weight Tester Tester Calibrator Resistance Decade Multifunction Calibrator Vintage Microscope Objective Guildline Calibrator Tested Frequency Standard Oscillator Ac Calibrator Portable Calibrator Process Calibrator Laser Optics Bin 1 Standard Capacitor Altek Calibrator Dc Calibrator Altek Model Decade Resistance Decade Resistance Box Hp Calibration Kit Ohm Resistance Standard Mil Spec Laser Optics Decade Resistor Mil Spec Laser Optical Optics Bin 3 Torque Tester Fluke Standard Esi Resistor Druck Calibrator Optics Assembly Huge Optics Dead Weight Pcb Accelerometer Fluke 5100B Transmation Pps Mm Dia Fl Optics Window Ametek Calibrator Dc Voltage Calibrator Optical Mounted Prism Laser Optics Optics Coated Lens Lens Mil Spec Laser Optics Pressure Calibration Flow Calibrator Calibrator Type Calibrator Thermometer Documenting Process Calibrator Fluke 5100B Calibrator Optics Fixture Iet Digital Calibrator Hp Calibrator Newport Optics 10-32 For Accelerometer Optics Prism Rubidium Frequency Standard Rubidium Standard Transmation Druck Dpi Optics Device Rubidium Frequency Mm Laser Optics Standard Resistor Temperature Calibrator Standard Cell Rtd Calibrator Bliley Quartz Pcb Piezotronics Piezotronics Quartz Crystal Frequency Altek Calibration Fixture Calibrator Hart Leitz Wetzlar Germany Microscope Frequency Calibrator Pure Chemical Coated Laser Optics Tektronix Calibration Calibration Model Calibrator Free Shipping Nist Calibrator Microscope Ocular Genrad Gr Gr General Radio Genrad Pressure Module Optical Prism Optics Coated Filter Rubidium Optics Glass Melles Griot Optics Voltage Calibrator Hart Scientific Torque Calibrator Thermometer Calibrator Dc Voltage Standard Programmable Calibrator Dry Calibrator Optics Lens Convex Datron Transmation Model Meter Calibrator Bliley Calibration System Torque Analyzer Filter Laser Optics Quartz Oscillator Optical Coated Optics Beam Splitter Calibrator Source Radio Genrad Vibration Sensor Verification Kit Calibrator Module Optics Micrometer Endevco Nice Optics Ametek Jofra Infrared Laser Optics Lamp Microscope Bin 11 Ea Lamp Dc Reference Standard Resonator Frequency Reference Standard Endevco Meggitt Accelerometer Accelerometer Pressure Charge Amplifier Guildline Standard Resistor- Accuracy 9330 Portable Pressure Calibrator Electro Scientific Industries Voltage Current Calibrator Calibration Standard Decade Capacitor Endevco Model Range Calibrator Ge Druck Dpi Bin Pmel Dead Weight Pressure Meter Calibration Resistance Calibrator Fluke 5700A Microscope Objective Optics Valhalla Scientific Leeds Northrup Primary Flow Calibrator Calibrator Multimeter Japan Optics Frequency Standard Calibrator Signal Resistor 100 Mirror Laser Optical Low Noise Cable Japan Microscope Beam Splitter Bliley Crystal Multifunction Process Calibrator Short Load Voltage Divider Dry Block Calibrator Mirror Laser Optics Torque Meter Nist Mirror Filter Optics Flat Calibrator Pump Transfer Standard Chip Resistor Calibration Test Datron Wavetek Analyzer Calibrator Positioner Stage Efratom Genrad Precision Decade Bin 7 Fluke Hart Scientific
 In 
 
Order by: 
Available to: 
Price: 
 - 
$
199
Buy It Now
$0 Shipping
Condition: Used
Location: Putnam,CT,USA
$
259.99
Buy It Now
$34.75 Shipping
Condition: Used
Location: Baton Rouge,LA,USA
$
52.95
Buy It Now
$0 Shipping
Condition: Used
Location: Albuquerque,NM,USA
$
259.99
Buy It Now
$34.75 Shipping
Condition: Used
Location: Baton Rouge,LA,USA
$
479.99
Buy It Now
$25 Shipping
Condition: Used
Location: Saint Louis,MO,USA
$
399.99
Buy It Now
$19.99 Shipping
Condition: For parts or not working
Location: Chicago,IL,USA
$
295.95
Buy It Now
$19.95 Shipping
Condition: Used
Location: San Antonio,TX,USA
$
599.99
Buy It Now
$20 Shipping
Condition: Used
Location: Chicago,IL,USA
$
249.99
Buy It Now
$20 Shipping
Condition: For parts or not working
Location: Chicago,IL,USA
$
249
Buy It Now
Free Shipping
Condition: Used
Location: Lindenhurst,NY,USA
$
449.99
Buy It Now
$19.99 Shipping
Condition: For parts or not working
Location: Chicago,IL,USA
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5108 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5109 10 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5109 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 10 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
614.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5108 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5108 5 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5108 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 5 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5114 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5114 500 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5114 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 500 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5107 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5107 1 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5107 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5110 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5110 20 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5110 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 20 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5111 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5111 30 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5111 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 30 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5112 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5112 50 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5112 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 50 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5102 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5102 5mkH 0.2 0.5 0.5 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5102 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 5mkH Accuracy class 1 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5113 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5113 100 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5113 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 100 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform
$
657
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5115 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5115 1 H 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5115 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 H Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform with
$
167
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5101 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5101 1mkH 0.4 1 1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5101 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1mkH Accuracy class 2 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform with a
$
2,167
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
G79 Exact Micro Teslameter. Gaussmeter, Magnetometer analog of Alpha Lab, F.W. Bell, but has the same or better characteristics. Microteslameter G79 is ... moreused to measure the rms values of the magnetic induction from 0.02 mkT to 1000mkT alternating magnetic fields with frequency from 20Hz to 20kHz in a small volume of space. Measurement range: 0.02 mkT- 1000mkT; Measured chanels settings: 0.1mkT.0.3mkT; 1mkT; 3mkT; 10mkT; 30mkT; 100mkT;300mkT; 1000mkT; Measurement range: 20Hz- 20kHz; High Accuracy class: 5% Voltage: 220V. 50Hz or 6 built-in batteries; Power consumption: 6 V ∙ A; Weight: 6 kg. Warranty 12 months. The presence of the analog output allows to research the magnetic induction waveform and automate the processes of measurement and control with the help of connected analyzing and reproducing devices. Microteslameter G79 consists of measuring panel and two interchangeable sensors. Diameter of the probe- 13.0 mm. The length of the probes sensitive part 6.0 mm. 20.0 mm; Microteslameter can be used in the determination of magnetic compatibility at adjusting and non-destructive testing of nodes. Blocks, and elements of radio and electronic devices; In contrast to similar samples Microteslameter G79 has an extended amplitude and frequency ranges; Microteslameter G79 Power supply- 220V, 50Hz. Or from six built-in battery type 3336(or analog) The power consumed does not exceed 6V•A; The manufacturer guarantees that the quality of devices Microteslameter G79 corresponds to the technical requirements TR. If consumering the terms and conditions of storage. Transportation. Installation, operation, established by the technical conditions and operational documents. Microteslameter G79 is used to measure the rms values of the magnetic induction from 0.02 mkT to 1000mkT alternating magnetic fields with frequency from 20Hz to 20kHz in a small volume of space. This device can be connected to other devices with the use of special connector. Consists of measuring controlel and two interchangeable probes( di
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5105 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5105 100mkH 0.025 0.05 0.1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5105 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 100 mkH Accuracy class 0.05 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal wavefor
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5103 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5103 10mkH 0.066 0.1 0.1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5103 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 10mkH Accuracy class 0.2 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal wavefo
$
420.99
Buy It Now
$170 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
595.99
Buy It Now
$190 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5104 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5104 50mkH 0.033 0.05 0.2 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5104 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 50mkH Accuracy class 0.1 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wi
$
167
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5106 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5106 500mkH 0.025 0.05- Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5106 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 500 mkH Accuracy class 0.05 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
3,933
Buy It Now
$175 Shipping
Condition: New – Open box
Location: Ukraine
P5083 Multifunctional. Multivalued decade resistance box. Bridge, resistor. Potentiometer analog of: General Radio(GenRad) LEEDS& NORTHRUP, ESI, IET ... moreLabs, GR, Yokogawa, Shallcross, Tinsley& Co, Shallcross, Leeds& Northrup, L&N, Extech, EMCO, AEMC devices. But has the same or better characteristics: AC Bridge P5083 is an autonomous measuring device for general industrial purposes and designed for automatic measurements of: capacitance C. Inductance L. Active resistance R. Tangent loss tgδ( Q Qr) tangent angle of phase shift tgφ( Q Qc and QL) of measuremed objects. And also a percentage deviation of measured object with further presentation of measurement results in digital form. AC bridge P5083 can be used for: Scientific researches; Metrological measuring instruments attestation; Quality control of electrical and radiotechnical products; Nonelectrical values measurement with a use of nonelectrical values transformers into one of measured values. Min. Value of accuracy class: With an external model of calibration) 0.02/0,002(0.005/0,0002) The range of measured values ​​: resistance. Ohm from 1·10-5 to 1·10 10 capacitance from 1·10-16 to 10 inductance from 1·10-10 to 1·10 7 angle shift tangent(tg φ) from ± 1·10-5 to ± 1·10 +5 deviation percentage. from ± 0.001 to ± 100 frequency.KHz(3000 discrete frequencies installed) from 0.1 to 100 Discrete digital frame(on low range of measurements) active resistance. Ohm 1·10-5 capacitance 1·10-16 inductance 1·10-10 AC range of values. On-site measurements(dependingon the measuredvalues​​) V. From 0.01 to 30 Dimensions: 440 x158x405mm; Weight: 16 kg. Warranty 12mounth. Technical characteristics of AC bridge P5083: D epending on frequency and voltage of measurement object. Values measured by the AC bridge correspond to those shown in Table 1; Table1 Main Additional main derivative C Cp Rp tgδ c(Q R) Cs Rs L Lp Rp tgδ L(Q R) Ls Rs R Rp Cp tgδ c(Q C) Lp tgδ L(Q L) Rs Cs tgδ c(Q C) Ls tgδ L(Q L)
$
999.68
Buy It Now
$170 Shipping
Condition: New – Open box
Location: Ukraine
Voltage comparator P3003. Analog of Lutron. Advantest. Avtech, HP Agilent. NoiseCom, General Radio. Boonton, Anritsu, Fluke and general Electric, but ... morehas the same or better characteristics. This device can be used for wide measurement range. Voltage comparator P3003 Is designed for: DC voltage comparison(relative measurement) voltage measurement(with normal element class 0.001. II level) calibrated voltage issuance; voltage increase. Accuracy class 0.0005. Voltage comparators P3003(hereinafter comparators) differential. Accuracy class 0.0005 are designed for: DC voltage comparison(relative measurement) voltage measurement(with normal element class 0.001. II level) calibrated voltage issuance; voltage increase Voltage comparator P3003 includes modes with external digital and analog output meter. Comparator operating conditions: ambient temperature- from +10 ° C to +35 ° C. Relative humidity- 80% at 25 ° C, voltage supply- 220 ± 22)V, at frequency 50, 60Hz. Voltage comparator P3003. Is designed for areas with tropical climates, corresponds to performance 0 category 4.1. And operate at temperatures from 10 ° to 35 ° C. Comparator model P3003- 04.1. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics of device inductance standard P547: Differential voltage comparator. When measuring and comparing voltages calibrator built jointly operate together. Differential instrumentation amplifier, differential micro voltmeter, input voltage divider. Compared and measurement limits calibrator compensated voltage input voltage: 11.111110 V; 1.1111110 V; 0.1
$
4,000
Buy It Now
$999.99 Shipping
Condition: New – Open box
Location: Ukraine
$
549.99
Buy It Now
$25 Shipping
Condition: For parts or not working
Location: Chicago,IL,USA
$
449.99
Buy It Now
$15 Shipping
Condition: For parts or not working
Location: Chicago,IL,USA
1
 In 

Past Items  
 
Item up for sale is a: General Radio Co Standard Inductor Type 1482-P 1H +/ 0.1% This item is NOT tested unless otherwise noted. If you have any questions regarding this item please feel free to contact me and I will do my best to answer your questions 1 item as shown in picture. Picture represents the actual item. ~14 Pounds in a box with packaging materials Included is only what is mentioned. No other cables. Parts, power cords, power adapters, software or any other accessories included. Payment options: PayPal only or contact us for payment methods to pay on pickup. Warranty for US shipments: 14 days testing period unless the auction specified as final sale. Buyer must return the product back to the company in a timely manner. Refund upon receiving and inspecting of product and for the cost of the product only. Restocking fee may apply ... morefor the new product shipped. Warranty for International shipments: All international orders are final. No exception. Shipping: Buyer is responsible for all shipping cost including returns. Please note for domestic shipments(within US) we ship Fedex ground only. But you can use UPS ground shipping rates(calculated automatically by ebay) to estimate the shipping charges. Actual Fedex ground rates may be cheaper then UPS depending on the destination, so for heavy packages you can always contact us to get the exact shipping rate. FEDEX does not ship to PO Boxes- please provide us with a regular address prior to completing the transaction. International Shipments: International shipments are shipped by USPS global express mail if such option is available. We process international shipments twice a week. Please note that Buyer is responsible for all custom duties/taxes/fees where applicable. Import duties. Taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. We do not mark merchandise values
This is a GENERAL RADIO CO. STANDARD INDUCTOR TYPE 1482-M 200mh ± 0.1% This item is untested and being sold as is. See photos for item details. Hawaii. Alaska, PR, will have added shipping surcharges, please ask for quote prior to bidding. Powered by The free listing tool. List your items fast and easy and manage your active items.
This General Radio 1482N 500 mH +/ 0.1% Standard Inductor is in very good condition working well. Nice clean unit. The General Radio 1482-N Standard Inductor is an accurate. Highly stable standard of inductance for use as a low frequency reference or working standard in the laboratory. Long term stability is typically well within the specified ±0.1% This unit is sold as-is.
General Radio Co Standard Inductor Type No 1482-F 2mH Item is UNTESTED- no testing has been done. Sold"as is" Condion: some normal wear. Scuffs, etc, some dust, some old stickers stuck onetc see pics for condition. Sold"as is" ===== Please note: Processing time can be up to 5 BUSINESS DAYS. Prior to your item shipping. This is in addition to the actual shipping time, please do not buy unless you are ok with the possibility of an extended shipping time. Please review eBay’s shipping calculator for an ESTIMATE of arrival. Please do not leave a LOW RATING on shipping time as your Purchase and knowledge of the shipping time indicates you are completely satisfied with the shipping time posted in ebay shipping arrival estimate. ========== Buyer to pay for shipping in the United States(use Shipping Calculator) Feel free to request ... morequote for other shipping Methods) International shipping via USPS International(based on availability)international request rates prior to bidding(use shipping calculator) International Buyers– Please Note: Import duties. Taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. I accept Payment through PayPal. All Sales Final. Item is sold"AS IS" No warranty expressed or implied. Winning bidder is to pay for item 3 days after end of auction. Questions are More than welcome!
General Radio Standard Inductor Type 1481-M 5h ± 0.25% UP FOR AUCTION IS A GENERAL RADIO STANDARD INDUCTOR TYPE 1481-M 5H ± 0.25% THE UNIT COMES FROM A WORKING ENVIRONMENT. BUT WE ARE UNABLE TO PERFORM TESTING HERE AT NEXTSTEP. THERE ARE A FEW SCUFFS AND SCRATCHES, BUT OVERALL THIS UNIT APPEARS TO BE IN VERY GOOD CONDITION. Satisfaction guaranteed! If you are not completely satisfied. You may return the item within 14 days of purchase for a full refund. Questions welcome. Items are usually shipped USPS by the next business day after payment is received. We often ship within one business hour of payment. Our eBay hours are Monday to Friday 10-6 Pacific. International customers. Please ask about shipping options before bidding. As part of our mission to reduce waste. 100% of packing materials are reused(except Priority Mail flat rate ... moreboxes) All items will be properly packed, but your foam packing peanuts may not match. If you are not happy with the item you've purchased. We will work to resolve the situation to your satisfaction. Please give us a chance to fix a problem before leaving feedback. Thank you for supporting NextStep Recycling!