Ohm Standard Resistor Optics Positioner Laser Optics Bin 3 Unknown Optics Laser Optical Bin 3 Current Calibrator Calibrator Standard Pneumatic Calibrator Cable For Accelerometer Omega Calibrator Ea Optics Thermocouple Calibrator Optics Bin 4 Standard Inductor Unknown Application Calibrator 0 Piezoelectric Accelerometer Calibration Vibration Optical Bin 1 Optical Bin 3 Precision Calibrator Loop Calibrator Resistance Standard Voltage Standard Dead Weight Tester Tester Calibrator Resistance Decade Multifunction Calibrator Vintage Microscope Objective Guildline Calibrator Tested Frequency Standard Oscillator Ac Calibrator Portable Calibrator Process Calibrator Laser Optics Bin 1 Standard Capacitor Altek Calibrator Dc Calibrator Altek Model Decade Resistance Decade Resistance Box Hp Calibration Kit Ohm Resistance Standard Mil Spec Laser Optics Decade Resistor Mil Spec Laser Optical Optics Bin 3 Torque Tester Fluke Standard Esi Resistor Druck Calibrator Optics Assembly Huge Optics Dead Weight Pcb Accelerometer Fluke 5100B Transmation Pps Mm Dia Fl Optics Window Ametek Calibrator Dc Voltage Calibrator Optical Mounted Prism Laser Optics Optics Coated Lens Lens Mil Spec Laser Optics Pressure Calibration Flow Calibrator Calibrator Type Calibrator Thermometer Documenting Process Calibrator Fluke 5100B Calibrator Optics Fixture Iet Digital Calibrator Hp Calibrator Newport Optics 10-32 For Accelerometer Optics Prism Rubidium Frequency Standard Rubidium Standard Transmation Druck Dpi Optics Device Rubidium Frequency Mm Laser Optics Standard Resistor Temperature Calibrator Standard Cell Rtd Calibrator Bliley Quartz Pcb Piezotronics Piezotronics Quartz Crystal Frequency Altek Calibration Fixture Calibrator Hart Leitz Wetzlar Germany Microscope Frequency Calibrator Pure Chemical Coated Laser Optics Tektronix Calibration Calibration Model Calibrator Free Shipping Nist Calibrator Microscope Ocular Genrad Gr Gr General Radio Genrad Pressure Module Optical Prism Optics Coated Filter Rubidium Optics Glass Melles Griot Optics Voltage Calibrator Hart Scientific Torque Calibrator Thermometer Calibrator Dc Voltage Standard Programmable Calibrator Dry Calibrator Optics Lens Convex Datron Transmation Model Meter Calibrator Bliley Calibration System Torque Analyzer Filter Laser Optics Quartz Oscillator Optical Coated Optics Beam Splitter Calibrator Source Radio Genrad Vibration Sensor Verification Kit Calibrator Module Optics Micrometer Endevco Nice Optics Ametek Jofra Infrared Laser Optics Lamp Microscope Bin 11 Ea Lamp Dc Reference Standard Resonator Frequency Reference Standard Endevco Meggitt Accelerometer Accelerometer Pressure Charge Amplifier Guildline Standard Resistor- Accuracy 9330 Portable Pressure Calibrator Electro Scientific Industries Voltage Current Calibrator Calibration Standard Decade Capacitor Endevco Model Range Calibrator Ge Druck Dpi Bin Pmel Dead Weight Pressure Meter Calibration Resistance Calibrator Fluke 5700A Microscope Objective Optics Valhalla Scientific Leeds Northrup Primary Flow Calibrator Calibrator Multimeter Japan Optics Frequency Standard Calibrator Signal Resistor 100 Mirror Laser Optical Low Noise Cable Japan Microscope Beam Splitter Bliley Crystal Multifunction Process Calibrator Short Load Voltage Divider Dry Block Calibrator Mirror Laser Optics Torque Meter Nist Mirror Filter Optics Flat Calibrator Pump Transfer Standard Chip Resistor Calibration Test Datron Wavetek Analyzer Calibrator Positioner Stage Efratom Genrad Precision Decade Bin 7 Fluke Hart Scientific
 In 
 
Order by: 
Available to: 
Price: 
 - 
$
6.89
Buy It Now
$13.1 Shipping
Condition: New
Location: United Kingdom
$
750
Buy It Now
$0 Shipping
Condition: Used
Location: India
$
13.53
Buy It Now
$0 Shipping
Condition: New
Location: China
$
3,521
Buy It Now
$0 Shipping
Condition: Used
Location: India
$
3,521
Buy It Now
$0 Shipping
Condition: Used
Location: India
$
1,595
Buy It Now
$39.95 Shipping
Condition: Used
Location: Elgin,IL,USA
Click the images to enlarge. Click images to enlarge. Hewlett Packard Agilent 85054A Type N Calibration Kit With 905A Sliding Load Description: Up for ... moreAuction is an HP Agilent 85054 Type N Calibration Kit. This Calibration kit is in Good physical condition. Showing some light wear on the adapters and scratching on the wooden case exterior. A certificate of Calibration shows a Calibration date of 06-August-1992. We are not knowledgeable with this exact type of item, so we are unable to test and are offering it for sale AS-IS for parts or repair. All components appear to be in Good working condition. The protective foam inside the case is not in good condition. And peels away very easily, due to the age of the material. We recommend replacing the foam right away. Please see pictures for more details! Happy Bidding! Physical Condition: Good Working Condition: We lack the capabilities to test this item. AS-IS PLEASE READ BEFORE BIDDING All items that we sell are guaranteed to be as described in the listing. Everything that is included in the auction is described and/or pictured above. If there is no indication of whether something is included. Please do not assume it is. Parts or repair items and items that we cannot fully test are only guaranteed to have the functionally described. No further functionality can be guaranteed for these items. Used printing consumables and batteries are not guaranteed. Feel free to ask us a question before bidding. Thank you for shopping with us! For more GREAT DEALS from MCLEAN-SURPLUS. Please feel free to check out our eBay store. Payment For payment by PayPal. Please checkout through eBay. For payment by credit card over the phone. Please call 703-534-5865 after committing to purchase through eBay. Our hours for credit card payment are Monday- Friday 10 AM to 5 PM EST. Local Pickup Local pickup is available at our location in Falls Church. Virginia from Monday- Saturday 10AM- 5PM. If you have won the item and prefer to pick it up, please click"Request Invoice" or send us a
$
850
Buy It Now
$200 Shipping
Condition: Used
Location: France
$
9,950
Buy It Now
$95 Shipping
Condition: Seller refurbished
Location: Culver City,CA,USA
IET/ General Radio 1408 Air Bath Reference Standard Capacitor You are bidding on an IET/ General Radio 1408 Air Bath Reference Standard Capacitor. This ... moreunit is in excellent condition. Has been fully tested and is ready to ship. Link to the Datasheet: Description: The continuously improving accuracy of capacitor calibrations by NIST brings a better knowledge of capacitance to standards laboratories provided. Of course, the laboratories have adequate reference standards. The 1408 Reference Standard Capacitors, with their high stability, are suitable for calibration in parts in 107. The 1616(not included) Precision Capacitance Bridge is highly recommended for accurate calibration of a wide range of working standards from such a reference. The unit includes two standards. 10 pF and 100 pF, plus a self-contained air bath whose temperature is held constant to within 0.01 per year to assure the utmost stability of the standards. Since it carriers its own environment, it is well adapted for use in laboratories without an oil bath or closely-controlled ambient temperature or in portable laboratories and calibration centers. The air bath operates from 12 volts so that it is an easy matter to transport it under power at all times. Features: 10 pF and 100 pF combination High stability Low voltage coefficient Terminals: Two GR-874 locking connectors or BNC connectors(connectors not included but can be supplied at an additional cost) Specifications: Nominal Value: 10 pF and 100 pF. Adjustment Accuracy: ±5 ppm. Stability: Estimated to be better than 1 ppm per year. Temperature Coefficient: 2 ±2 ppm/°C for 100 pF; 5 ±2 ppm/°C for 10 pF. Electrical: Dissipation Factor: Voltage: 750 V max. Residual Impedance: See the datasheet- Figure 1(in specifications area towards the bottom) Terminals: Two locking G874 coaxial connectors or BNC connectors(not included) Air-Bath Characteristics: Temperature: 30°C nominal with stability of 0.01°C/year. Temperature Coefficient: 0+0.05 ppm/°C from 17 to 29&#
$
22
Buy It Now
$5.5 Shipping
Condition: New – Open box
Location: Ilion,NY,USA
Delivery Information tracking number will be sent to the buyer. Treatment time: up to 1 business days of accepting payment(except holidays) Delivery time: ... more2-5 business days Returns Policy We accept the return within 3 days since the buyer received the package. Buyer pays return shipping and handling fees. Refund will only be PayPal account Refund will be transferred only after he received the products. My return policy is: 100% money back guarante Newsletter Product Summary[2013 VERSION] Updated EatSmart Auto-On Technology and Sensor Accuracy. Large 3.5" LCD display w/ Accubright blue backlight- Easy to read from any distance or angle! 4 High Precision EatSmart Sensors- Consistent and accurate measurement up to 400 lbs or 180 kgs every time; Graduation increments of.2 lbs. 3oz. Sturdy 8mm thick tempered glass top and large 12" x 13" platform FREE EatSmart Body Tape Measure now included- Another great tool to monitor progress! Auto Calibrated; Auto Power-Off; Runs on 4 AAA batteries(included) 100% EatSmart Satisfaction Guarantee. Payment Information At this time we accept PayPal only We appreciate your immediate payment. Product Description NEW FEATURES(2013 VERSION) EatSmart"Step-On" technology allows you to simply step on the scale and get your weights. No more tapping to activate the scale! Increased capacity to 400 pounds with the same precision and repeatability that makes our products great! Overview: The EatSmart Bathroom Scale is the ideal way to track your weight loss quickly and easily. Simply step on. And in seconds you'll have an accurate readout to the nearest.2 lbs on the EatSmart's oversized 3.5" Accubright LCD display. With EatSmart's proprietary new"step-on" technology there is no more tapping to turn the scale on! The LCD display also contains a cool-blue backlight, allowing for easy viewing even in the most low light areas of the bathroom or home. Industry Leading Design and Accuracy: The EatSmart Digital Bathroom Scale is also not only easy to
$
7.4
Buy It Now
$13.75 Shipping
Condition: New
Location: United Kingdom
$
12.17
Buy It Now
$1.05 Shipping
Condition: New
Location: China
$
583.99
Buy It Now
$85 Shipping
Condition: New – Open box
Location: Ukraine
P534/3 Variable Capacitor 0.5pF-152pF 0.5% Analog of Jennings. General Radio(GR. Genrad) IET Labs but has the same or better characteristics. Technical ... morecharacteristics: Measurement range: 0.5pF-152pF Accuracy: 0.5% Weight: 5kg Warranty 12 month. This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: Used. An old stock. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics: Temperature +10 +35 ° C; Relative humidity up to 80% This device can be also named as: P-594/3. P 594/3, P 594/3, R 594/3, R 594/3, R- 594/3. Р 594/3, р- 594/3, Р 594/3, capacitor standard. Capacitors standard. Standard capacitance. Laboratory standard, high precision capacitor. Etalon capacitor. Photos If necessary we can take photos of a device from various angles. Technical Documentation In case you didn't find in technical specifications for the device all necessary information you are interested in. Feel free to contact me. I will look through the technical documentation for the device and I will be happy to consult you. Also I may speak directly with the manufacturer and find out more specific information about this product. If some technical parameters for the device(error. Accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time. On delivering the device. Electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be doc
$
2,150
Buy It Now
$140 Shipping
Condition: New – Open box
Location: Ukraine
P3027-1 Decade Voltage Devider. Dekavider analog of Fluke,HP,General Radio,EMCO,ESI. Shalltronix, Reliance Electric, Agilent, Boonton Electronics, Tektronix, ... morebut has the same or better characteristics. High precision DC Voltage Divider P3027-1 Designed to expand the limits of measurements of electrical devices in DC. And for testing voltage dividers. Division coefficient Nominal input voltage. V Input resistance. KOhm divider circuit protection circuit general 10 10 V 10±0.03 55.4±0,5 8.47±0,05 100 100 V 100±0.3 554±5 84.7±0,5 1000 1000 V 1000±3 5540±50 847±5 Division coefficient 10- Nominal input voltage: 10V; Division coefficient 100- Nominal input voltage: 100V; Division coefficient 1000- Nominal input voltage: 1000V; Power: 220±22) V; Frequency: 50-60HZ; Power consumption: 30A*V; High Accuracy class: 0.0002% Max Voltage 3kV; The average service: at least 10 years. Dimensions: 440x160x460 mm; Weight: 11 kg. Warranty 12 Months. Technical characteristic: The voltage divider P3027-1. Is designed for operation under the conditions shown in Table1. Nominal values of the coefficients of division and the corresponding values of the input resistance and input voltage corresponds to those indicated in the Table2. Value of the output resistance of the divider for all of the coefficients- 1000 ± 3) ohm. DC voltage divider P3027/1 has a special option of offline verification and adjustment of the division coefficients. The main measuring resistance of VD are placed in the active thermostat. Time required to establish the temperature in the thermostat does not exceed 2 hours. Duration of continuous operation of VD is not less than 8 hours. Not including time of the operating mode establishment. Acceptable basic error P3027-1. Is shown in percentage of the nominal values of division coefficient and in working mode is equal ± 0.0002% Inspection and adjustment of the division coefficients must be held each 2 days in order to provide accuracy in normal condition. Admi
$
7.37
Buy It Now
$13.76 Shipping
Condition: New
Location: United Kingdom
$
4,995
Buy It Now
$49.95 Shipping
Condition: Used
Location: Elgin,IL,USA
Up for sale is a used and uncalibrated Agilent 85052B 3.5 mm cal kit. Includes what is shown and looks to be complete. See pictures for details and add ... more25.00 for shipping and insurance. Call or email with any questions at 8472175546. A 14 day inspection period and ROR is granted per discription as discribed. RcmdId ViewItemDescV4,RlogId p4%60bo7%60jtb9%3Fvo%7B%3Dd70f%2Bf54%3E-1419f2b8cd9-0xf9-
$
26.39
Buy It Now
$0 Shipping
Condition: New
Location: China
$
11.76
Buy It Now
$0 Shipping
Condition: New
Location: China
This weight set is perfect for checking the accuracy of your digital. Balance or mechanical scales. Class: OIML Class M2 Suitable for general laboratory. ... moreCommercial, and educational use 17 Weights are included as well as accessories: 1x 100g- 1x 50g- 2x 20g- 1 x 10g- 1 x 5g- 2 x 2g- 1 x 1g- 1 x 500mg- 2 x 200mg- 1 x 100mg- 1 x 50 mg- 2 x 20 mg- 1 x 10 mg- tweezers and travel/ storage case are included! In Stock and Ready to Ship! I Ship Fast!
$
242.84
Buy It Now
Free Shipping
Condition: Used
Location: Canada
$
242.84
Buy It Now
Free Shipping
Condition: Used
Location: Canada
$
999.99
Buy It Now
$58 Shipping
Condition: Used
Location: Milton Freewater,OR,USA
$
29.95
Buy It Now
$0 Shipping
Condition: Used
Location: Rocklin,CA,USA
$
88.99
Buy It Now
$0 Shipping
Condition: Used
Location: Rocklin,CA,USA
$
155
Buy It Now
$30 Shipping
Condition: New
Location: China
$
184.91
Buy It Now
$15 Shipping
Condition: New
Location: China
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5103 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5103 10mkH 0.066 0.1 0.1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5103 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 10mkH Accuracy class 0.2 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal wavefo
$
247.91
Buy It Now
Free Shipping
Condition: Used
Location: United Kingdom
$
243.35
Buy It Now
$8.95 Shipping
Condition: Used
Location: Santa Rosa,CA,USA
$
7.42
Buy It Now
$13.76 Shipping
Condition: New
Location: United Kingdom
$
18.85
Buy It Now
$0 Shipping
Condition: New
Location: China
$
573.99
Buy It Now
Free Shipping
Condition: Used
Location: Milpitas,CA,USA
$
4.74
Buy It Now
$0 Shipping
Condition: New
Location: China
$
178
Buy It Now
$15 Shipping
Condition: New
Location: China
$
299.99
Buy It Now
$14.5 Shipping
Condition: Used
Location: Manassas,VA,USA
$
185.13
Buy It Now
$15 Shipping
Condition: New
Location: China
$
185.13
Buy It Now
$15 Shipping
Condition: New
Location: China
$
750
Buy It Now
$200 Shipping
Condition: Used
Location: France
$
850
Buy It Now
Free Shipping
Condition: Used
Location: Farmingdale,NJ,USA
$
202.36
Buy It Now
Free Shipping
Condition: Used
Location: Canada
$
9.63
Buy It Now
Free Shipping
Condition: New
Location: United Kingdom
$
10.69
Buy It Now
$0 Shipping
Condition: New
Location: China
$
59.95
Buy It Now
$0 Shipping
Condition: Used
Location: Rocklin,CA,USA
$
185.13
Buy It Now
$15 Shipping
Condition: New
Location: China
$
8.13
Buy It Now
Free Shipping
Condition: New
Location: United Kingdom
$
9.63
Buy It Now
$13.76 Shipping
Condition: New
Location: United Kingdom
$
145
Buy It Now
Free Shipping
Condition: Used
Location: Laguna Hills,CA,USA
HP Agilent 8493A Coaxial Fixed Attenuator 10 dB. DC to 12.4 GHz Description The Agilent 8493A coaxial fixed attenuator provides precision attenuation. ... moreFlat frequency response, low SWR over broad frequency range at a low price. The attenuator is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 30 dB. This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit. Key F eatures& Specifications Superior RF Performance Frequency Range: DC to 12.4 GHz Maximum SWR: See table below for Maximum SWR Specifications Power handling Maximum Input Power: 2 W(average) 100 W(peak) Features Connector: SMA male. Female Sold as pictured. No additional software, manuals or accessories provided. Email your questions to sales@gstestequipment.com CA residents add 8% CA State Sales Tax. We buy your excess test equipment. Please contact sales@gstestequipment.com or call(949) 679-5561
$
3,914
Buy It Now
$0 Shipping
Condition: Used
Location: India
$
7.59
Buy It Now
$13.61 Shipping
Condition: New
Location: United Kingdom
$
14,500
Buy It Now
$99.95 Shipping
Condition: Used
Location: Elgin,IL,USA
$
447.61
Buy It Now
Free Shipping
Condition: New – Open box
Location: United Kingdom
$
390
Buy It Now
$140 Shipping
Condition: New – Open box
Location: Ukraine
P5000 Multivalued decade of mutual inductance. Inductance box, inductor standard analog of General Radio(GR, GenRad) IET Labs, but has the same or better ... morecharacteristics: Nominal frequency range: 5000Hz; Max frequency range: 10000 Hz; Max mutual inductance: 11.111 mH; Accuracy class: 0.2; Quantity of decades: 4; MTBF: not less than 24500 Hours; Dimensions: 405x215x240mm Weight: 11kg; Decades Upper value of normal frequencies range. KHz Extended range of frequencies. Hz Normal w inding current, A Max w inding current, A P rimary secondary P rimary secondary 1 mH-10 mH 1.5 1.5-2 0.25А 0.25А 0.5А 0.5А 0.1 m-1 mH 2.5 2.5-5 0.25А 0.25А 0.5А 0.5А 0.01 m-0.1 mH 2.5 2.5-5 0.5А 0.5А 1А 0.5А 0.00 m-0.01 mH 5 5-10 0.5А 0.5А 1А 1А Warranty 12 mounths This device was also used in USSR and Russia army. So it has best quality. Longevity and permanence characteristic. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Inductance box P5000 is designed to be used as mutual inductance standard in DC and AC circuits at frequency up to 10 kHz. Nominal frequency range up to 5000 Hz. Extended frequency range up to 10000 Hz. Highest value of mutual inductance 11.111 mH Accuracy class 0.2 Inductance boxes P5000 are designed to be used as mutual inductance standards in DC and AC circuits at frequency up to 10 kHz. Mutual inductance box P5000 is designed to be used in dry heated rooms in a temperate climate at ambient temperature from 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C) Technical characteristics Accuracy class 0.2 according to GOST 20798-75. The highest value of mutual inductan
$
12.01
Buy It Now
$0.69 Shipping
Condition: New
Location: China
$
535.99
Buy It Now
Free Shipping
Condition: Used
Location: Milpitas,CA,USA
$
6.87
Buy It Now
$0.69 Shipping
Condition: New
Location: China
$
830
Buy It Now
$130 Shipping
Condition: Used
Location: Ukraine
P310 or P321 or P331 Coil. Unevalued resistance standard resistor. SET of 9psc. 30% discount. P310 or P321 or P331 resistance standard resistor analog ... moreof LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 0.001- 0.01- 0.1- 1- 10- 100- 1000- 10000- 100000 Ohm. Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 0.001 P310 100 20 20 5 20 5 0.1 0.05 32 1000 0.01 P310 100 20 20 5 20 5 0.1 0.05 10 1000 0.1 P321 100 15 20 3 20 4 0.1 0.05 3.2 1000 1 P321 100 15 20 3 20 4 0.1 0.05 1 1000 10 P321 100 15 20 3 20 4 0.1 0.05 0.32 1000 100 P331 100 8 20 2 20 10 0.1 0.025 0.1 1000 1000 P331 100 8 20 2 20 10 0.1 0.025 0.032 1000 10000 P331 100 8 20 2 20 10 0.1 0.025 0.01 5000 100000 P331 100 8 20 2 20 10 0.1 0.025 0.0032 50000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) Warranty: 12 month. Electrical resistance coil Represents an exemplary resist ance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Accuracy class 0.01 Electrical resistance coil represents an exemplary resistance standard and is designed for testing and fitting working r
$
420.99
Buy It Now
$170 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
595.99
Buy It Now
$190 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5107 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5107 1 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5107 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
Inductance standard P547. Analog of Lutron. Advantest. Avtech, HP Agilent. NoiseCom, General Radio. Boonton, Anritsu, Fluke and general Electric, but ... morehas the same or better characteristics. This device can be used for wide measurement range. For sale is 1 of 4 devices. Please choose on from the table. Is designed to be used as a inductance standard in AC circuits with a maximum operating frequency 1500- 10000 Hz. Depending on inductance standard nominal value. Nominal value: 1 H. 0.1 H. 0.001 H. 0.0001 H Accuracy: 0.1% Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics of device inductance standard P547: Inductance standard P547 is designed to be used as inductance standard in AC circuits with a maximum operating frequency 1500- 10000 Hz, depending on inductance standard nominal value. Inductance standard P547 is produced with the following nominal values: 1 H. 0.1 H. 0.001 H. 0.0001 H. Inductor coil P547 is designed for operation at temperatures of 10 ° C to +35 ° C and relative humidity up to 80% Technical characteristics Parameters Parameters and characteristics value Note Deviation from nominal value a) ± 0.1% for all inductance values ​​ and in frequency range of not more than: L, H 1 0. 1 0. 01 0. 001 and 0. 0001 Hz max. 500 1500 5000 10000 b) inductance change at higher frequency relative to maximum operating frequency for"a" does not exceed 0.2% at L, H 1 0. 1 0. 01 Hz max. 1000 3000 10000 Ohm resistance do not exceed L H 1 0. 1 0. 01 0. 001 0. 0001 On standards indicated resistance at t = +20 ° C r ~ Ohm 140 20 1. 5 0
$
657
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5115 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5115 1 H 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5115 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 H Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform with
$
995
Buy It Now
Free Shipping
Condition: Used
Location: Farmingdale,NJ,USA
1 2 3 4 5 6 7 8 9 10 11 12 13 14
 In