Ohm Standard Resistor Optics Positioner Laser Optics Bin 3 Unknown Optics Laser Optical Bin 3 Current Calibrator Calibrator Standard Pneumatic Calibrator Cable For Accelerometer Omega Calibrator Ea Optics Thermocouple Calibrator Optics Bin 4 Standard Inductor Unknown Application Calibrator 0 Piezoelectric Accelerometer Calibration Vibration Optical Bin 1 Optical Bin 3 Precision Calibrator Loop Calibrator Resistance Standard Voltage Standard Dead Weight Tester Tester Calibrator Resistance Decade Multifunction Calibrator Vintage Microscope Objective Guildline Calibrator Tested Frequency Standard Oscillator Ac Calibrator Portable Calibrator Process Calibrator Laser Optics Bin 1 Standard Capacitor Altek Calibrator Dc Calibrator Altek Model Decade Resistance Decade Resistance Box Hp Calibration Kit Ohm Resistance Standard Mil Spec Laser Optics Decade Resistor Mil Spec Laser Optical Optics Bin 3 Torque Tester Fluke Standard Esi Resistor Druck Calibrator Optics Assembly Huge Optics Dead Weight Pcb Accelerometer Fluke 5100B Transmation Pps Mm Dia Fl Optics Window Ametek Calibrator Dc Voltage Calibrator Optical Mounted Prism Laser Optics Optics Coated Lens Lens Mil Spec Laser Optics Pressure Calibration Flow Calibrator Calibrator Type Calibrator Thermometer Documenting Process Calibrator Fluke 5100B Calibrator Optics Fixture Iet Digital Calibrator Hp Calibrator Newport Optics 10-32 For Accelerometer Optics Prism Rubidium Frequency Standard Rubidium Standard Transmation Druck Dpi Optics Device Rubidium Frequency Mm Laser Optics Standard Resistor Temperature Calibrator Standard Cell Rtd Calibrator Bliley Quartz Pcb Piezotronics Piezotronics Quartz Crystal Frequency Altek Calibration Fixture Calibrator Hart Leitz Wetzlar Germany Microscope Frequency Calibrator Pure Chemical Coated Laser Optics Tektronix Calibration Calibration Model Calibrator Free Shipping Nist Calibrator Microscope Ocular Genrad Gr Gr General Radio Genrad Pressure Module Optical Prism Optics Coated Filter Rubidium Optics Glass Melles Griot Optics Voltage Calibrator Hart Scientific Torque Calibrator Thermometer Calibrator Dc Voltage Standard Programmable Calibrator Dry Calibrator Optics Lens Convex Datron Transmation Model Meter Calibrator Bliley Calibration System Torque Analyzer Filter Laser Optics Quartz Oscillator Optical Coated Optics Beam Splitter Calibrator Source Radio Genrad Vibration Sensor Verification Kit Calibrator Module Optics Micrometer Endevco Nice Optics Ametek Jofra Infrared Laser Optics Lamp Microscope Bin 11 Ea Lamp Dc Reference Standard Resonator Frequency Reference Standard Endevco Meggitt Accelerometer Accelerometer Pressure Charge Amplifier Guildline Standard Resistor- Accuracy 9330 Portable Pressure Calibrator Electro Scientific Industries Voltage Current Calibrator Calibration Standard Decade Capacitor Endevco Model Range Calibrator Ge Druck Dpi Bin Pmel Dead Weight Pressure Meter Calibration Resistance Calibrator Fluke 5700A Microscope Objective Optics Valhalla Scientific Leeds Northrup Primary Flow Calibrator Calibrator Multimeter Japan Optics Frequency Standard Calibrator Signal Resistor 100 Mirror Laser Optical Low Noise Cable Japan Microscope Beam Splitter Bliley Crystal Multifunction Process Calibrator Short Load Voltage Divider Dry Block Calibrator Mirror Laser Optics Torque Meter Nist Mirror Filter Optics Flat Calibrator Pump Transfer Standard Chip Resistor Calibration Test Datron Wavetek Analyzer Calibrator Positioner Stage Efratom Genrad Precision Decade Bin 7 Fluke Hart Scientific
 In 
 
Order by: 
Available to: 
Price: 
 - 
$
595.99
Buy It Now
$190 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5107 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5107 1 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5107 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
Inductance standard P547. Analog of Lutron. Advantest. Avtech, HP Agilent. NoiseCom, General Radio. Boonton, Anritsu, Fluke and general Electric, but ... morehas the same or better characteristics. This device can be used for wide measurement range. For sale is 1 of 4 devices. Please choose on from the table. Is designed to be used as a inductance standard in AC circuits with a maximum operating frequency 1500- 10000 Hz. Depending on inductance standard nominal value. Nominal value: 1 H. 0.1 H. 0.001 H. 0.0001 H Accuracy: 0.1% Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics of device inductance standard P547: Inductance standard P547 is designed to be used as inductance standard in AC circuits with a maximum operating frequency 1500- 10000 Hz, depending on inductance standard nominal value. Inductance standard P547 is produced with the following nominal values: 1 H. 0.1 H. 0.001 H. 0.0001 H. Inductor coil P547 is designed for operation at temperatures of 10 ° C to +35 ° C and relative humidity up to 80% Technical characteristics Parameters Parameters and characteristics value Note Deviation from nominal value a) ± 0.1% for all inductance values ​​ and in frequency range of not more than: L, H 1 0. 1 0. 01 0. 001 and 0. 0001 Hz max. 500 1500 5000 10000 b) inductance change at higher frequency relative to maximum operating frequency for"a" does not exceed 0.2% at L, H 1 0. 1 0. 01 Hz max. 1000 3000 10000 Ohm resistance do not exceed L H 1 0. 1 0. 01 0. 001 0. 0001 On standards indicated resistance at t = +20 ° C r ~ Ohm 140 20 1. 5 0
$
520
Buy It Now
$155 Shipping
Condition: New – Open box
Location: Ukraine
P567 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics: ... moreNominal frequency range: 20- 5000 Hz; for decade x10: 20- 2500Hz; Extended frequency range: 5000- 10000 Hz; Accuracy class: 0.2% quantaty of decades: 10; Limits of inductance measurement: up to 111.1 mH; Max Current: 0.25A; Nominal Current: 0.2A; Dimensions: 405x215x235mm Weight: 11kg; Warranty 12 mounths This device was also used in USSR and Russia army. So it has best quality. Longevity and permanence characteristic. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Inductance box P567(Р-567. Р 567, p567, p 567, p-567) Designed to be used as inductance standard in AC measuring circuits at a frequency range from 20 Hz to 10000 Hz if all decades are connected. Except"x10" decade, which is designed for operation at frequencies up to 2500 Hz. Accuracy class 0.2 Inductance boxes P567 such as MICP are designed to be used as inductance standards in AC measuring circuits at a frequency range from 20 Hz to 10000 Hz if all decades are connected. Except"x10" decade, which is designed for operation at frequencies up to 2500 Hz. Devices are available in two versions: Inductance box P567- for work in closed rooms at an ambient temperature of +10 to +35 ° C and relative humidity of 30 to 80% Inductance box P567T– is designed for work in closed rooms at tropical climate. Technical characteristics Parameters Parameters and characteristics value Note Accuracy class of the box, according to GOST 10770-84 0.2 Nominal frequency range f
$
12.23
Buy It Now
$2.74 Shipping
Condition: New
Location: China
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5112 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5112 50 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5112 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 50 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
1,255.23
Buy It Now
$200 Shipping
Condition: New – Open box
Location: Ukraine
High Precision B1-16 AC Voltmeters programable Calibrator. Verificator, Tester analog of FLUKE,EDC,Agilent,Tektronix IET Labs. But has the same or better ... morecharacteristics. B1-16 is designed for white range AC Voltmeters calibration. Thechnical characteristics: Accuracy class: 2% Output Voltage 100mkV-3V; Output Voltage ranges: 0.316V-0.4V-0.5V-0.6V-0.7V-0.8V-0.9V-1V-1.5V-2V-2.5V-3V. Output Frequency rance: 10Hz- 50MHz; With fixed values: ​​ 10-20-30-40-45-55-100-200-300-400-450-550 Hz 1-2-3-4-4.5-5,5 10-20-30-40-45-100-200-500 kHz. 1-3-5-10-15-20-30-50 MHz. Output frequency and voltage controll type: remote or manual; Output resistance: 1-30-50 Ohm; Setlling time: less than 15 sec. Dimensions: 488x173x475mm; Weight: 20kg Warranty 12 month. This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: NEW(not used. But from an old stock) Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance clibrators, standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Device for В1-16 voltmeters verification d esigned for AC voltmeters testing in a wide frequency range. Output voltage range 100mkV- 3V with nominal rms values ​​corresponds to 0.316V-0.4V-0.5V-0.6V-0.7V-0.8V-0.9V-1V-1.5V-2V-2.5V-3V. Frequency range of output voltage 10 Hz-50 MHz with fixed values 10-20-30-40-45-55-100-200-300-400-450-550 Hz, 1-2-3-4-4.5 10-20-30-40-45-100-200-500-5.5 kHz. 1-3-5-10-15-20-30-50 MHz. Device В1-16 for voltmeters verification is designed for AC voltmeters testing in a wide frequency range. Devices В1-16 for voltmeters verification have remote and manual fixed frequency selection and nominal value of output voltage level and output to digital code on CPY. Can be used in automated calibration sys
$
657
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5115 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5115 1 H 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5115 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1 H Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform with
$
614.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5108 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5108 5 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5108 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 5 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
17.28
Buy It Now
$2.74 Shipping
Condition: New
Location: China
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5113 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5113 100 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5113 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 100 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform
$
599.87
Buy It Now
$120 Shipping
Condition: New – Open box
Location: Ukraine
P327 Multivalued Programable DC Calibrator analog of FLUKE.EDC,Agilent,Tektronix IET Labs. But has the same or better characteristics. Multivalued DC ... morevoltage calibrators P 327 are tools of general use, designed for calibration of such measuring devices: differential voltage comparators; potentiometers; digital voltmeters; measuring amplifiers; voltage calibrators. Voltage calibrator P 327 issues voltage discrete in exact linear ratio: 1-10)V(10·1V) 0.1-1)V(10·0.1V) 10-100)mV(10·10mV) 1-10)mV(10·1mV) 0.1-1)mV(10·0.1mV) 10-100)mkV(10·10mkV) 1-10)mkV(10·1mkV) 0.1-1)mkV(10·0.1mkV) Accuracy class: 0.02-0,4% Calibrated voltage limits: 1 mkV.10 mkV, 100 mkV, 1 mV, 10 mV, 100mV.1V, 10V; Minimum resistance load for 10V: 1kOhm; Output resistance limits: 0.5- 300 Ohm; Quantity of decades: 1; Calibrated voltage range 10-7- 10V; Voltage: 180-240V; Frequency: 50 Hz; Power consumption: 25 V*A; The average service 10 years; Dimensions 317х106х325 mm; Weight 6 kg. Voltage Calibrator P327 designed for operation at temperatures of 10 ° to 35 ° C and relative humidity of 80% at 25 ° C. Voltage Calibrator P327 designed for use in tropical climate should be used in rooms with air-conditioned at a temperature of 10 ° to 35 °(and marked as P327 0 4.1* C. AC voltage power supply of voltage calibrator P327 is(220 ± 22)V. Frequency of 50 Hz. On request for Voltage Calibrators P327 export 60 Hz frequency can be made. Technical characteristics Voltage Calibrator P327 has: Calibrated voltage measuring ranges: 1. 10, 100mkV. 1, 10, 100 mV. 1, 10V; Quantity of decades- 1; Decade scale division for stages is according to Table 1. Acceptable basic error limit of calibrators P327 installed linearity voltage in unloaded mode should correspond to values ​​shown in Table 1. Voltage calibrator acceptable basic accuracy class with normal element calibration is 0.001of 2-nd category corresponds to: ±(20U + 0.5) mkV during calibration interval of 1 hour; ±(40U + 3) mkV during
$
185.99
Buy It Now
$8 Shipping
Condition: New
Location: China
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5111 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5111 30 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5111 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 30 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5110 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5110 20 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5110 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 20 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5104 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5104 50mkH 0.033 0.05 0.2 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5104 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 50mkH Accuracy class 0.1 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wi
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5105 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5105 100mkH 0.025 0.05 0.1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5105 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 100 mkH Accuracy class 0.05 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal wavefor
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5108 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5109 10 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5109 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 10 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
15.96
Buy It Now
$0.69 Shipping
Condition: New
Location: China
$
2,999.46
Buy It Now
$999.99 Shipping
Condition: New – Open box
Location: Ukraine
High precision capacitance AC bridge P5026(Set) Multivalued. High-frequency decade capacitance box capacitor standard. AC bridge analog of General Radio(GR. ... moreGenRad) IET Labs, but has the same or better characteristics. AC bridge Р5026М is designed to measure capacitance and dielectric tangent loss of high-voltage industrial insulation for a"direct" both outputs of the measuring object isolated from the"earth" and" inverted" one output of the measured object is connected to"earth" schemes under operational conditions. Directly on the installation location, as well as measurements of"direct" scheme in the laboratory capacity and dielectric tangent loss of various insulating materials and condensers at 50 and 60Hz. P5026 Set includes: 1. P5026 AC bridge- 1psc. 2. Q5122 potential protector- 1set. 3. P5069 condenser block- 1psc. 4. P5023 Standart air condenser- 1 set. 5. Solid dielectrics testing electrodes- 1 set. 6. Power cord- 1psc. 7. Cables- 1 psc. 8. Manual and docs. Technical characteristics: M easurement range С х tgδ х 10 pF-1000 pF 1∙10-4-0.1 100 pF-10000 pF 1∙10-4-1.0 10 4 pF-2∙10 4 pF 2∙10 4 pF-10 5 pF 10 5 pF-10 6 pF 5∙10-4-1.0 100 pF-10000 pF 5∙10-3-1.0(10 4 pF-10 5 pF)10 5 pF-10 6 pF) 650 pF-2∙10 5 pF 5∙10-3-0.1 6500 pF-2∙10 6 pF 5∙10-3-1.0 2∙10 6 pF-5∙10 8 pF Measurement range Operating voltage Measurement schem e С х tgδ х 10 pF-1000 pF 1∙10-4-0.1 5 kV-10 kV« straight» with F 5122 and Р5069 100 pF-10000 pF 1∙10-4-1.0 3 kV-10 kV 10 4 pF-2∙10 4 pF 2∙10 4 pF 10 5 п pF 3 kV-5 kV« straight» with F 5122 10 5 pF-10 6 pF 5∙10-4-1.0 100 pF-10000 pF 5∙10-3- 1.0 3 kV-10 kV« straight» with« turned back» 10 4 pF-10 5 pF)10 5 pF-10 6 pF) 650 pF 2∙10 5 pF 5∙10-3- 0.1 0.1 kV« straight» 6500 pF-2∙10 6 pF 5∙10-3-1.0 2∙10 6 pF-5∙10 8 pF MTBF not less than: 5250 hours; The average service at least: 6 years; Dimensions: 540 x 280 x 380mm; Weight: 22kg. Warranty 12 month. AC Bridge Р5026М consists of the following components
$
13.53
Buy It Now
$0 Shipping
Condition: New
Location: China
$
13.53
Buy It Now
$0 Shipping
Condition: New
Location: China
$
4.61
Buy It Now
$0 Shipping
Condition: New
Location: China
$
12.09
Buy It Now
$0.69 Shipping
Condition: New
Location: China
$
10.19
Buy It Now
$0 Shipping
Condition: New
Location: China
$
185.13
Buy It Now
$5 Shipping
Condition: New
Location: China
$
17.09
Buy It Now
$2.6 Shipping
Condition: New
Location: China
$
944.74
Buy It Now
$130 Shipping
Condition: New – Open box
Location: Ukraine
P310 or P321 or P331 Coil. Unevalued resistance standard resistor. SET of 9psc. 30% discount. P310 or P321 or P331 resistance standard resistor analog ... moreof LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 0.001- 0.01- 0.1- 1- 10- 100- 1000- 10000- 100000 Ohm. Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 0.001 P310 100 20 20 5 20 5 0.1 0.05 32 1000 0.01 P310 100 20 20 5 20 5 0.1 0.05 10 1000 0.1 P321 100 15 20 3 20 4 0.1 0.05 3.2 1000 1 P321 100 15 20 3 20 4 0.1 0.05 1 1000 10 P321 100 15 20 3 20 4 0.1 0.05 0.32 1000 100 P331 100 8 20 2 20 10 0.1 0.025 0.1 1000 1000 P331 100 8 20 2 20 10 0.1 0.025 0.032 1000 10000 P331 100 8 20 2 20 10 0.1 0.025 0.01 5000 100000 P331 100 8 20 2 20 10 0.1 0.025 0.0032 50000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) Warranty: 12 month. Electrical resistance coil Represents an exemplary resist ance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Accuracy class 0.01 Electrical resistance coil represents an exemplary resistance standard and is designed for testing and fitting working r
$
11.58
Buy It Now
$0.69 Shipping
Condition: New
Location: China
$
499
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
P5102 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5102 5mkH 0.2 0.5 0.5 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5102 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 5mkH Accuracy class 1 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform wit
$
699.99
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5114 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5114 500 mH 0.01 0.04 0.06 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5114 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 500 mH Accuracy class 0.02 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform
$
12.23
Buy It Now
$2.74 Shipping
Condition: New
Location: China
$
6.87
Buy It Now
$0.69 Shipping
Condition: New
Location: China
$
390
Buy It Now
$140 Shipping
Condition: New – Open box
Location: Ukraine
P5017 Multivalued decade of mutual inductance. Inductance box, inductor standard set is analog of General Radio(GR, GenRad) IET Labs, but has the same ... moreor better characteristics: Variation range. MH + 12.99 Acceptable basic error limit. MH +(14х10-3 + 1.1х10-3 M) Inductance variation range From 4.5 to 10 Acceptable basic error limit. Deg + 0.4( M 0.1 mH) Variation range of residual mutual inductance. MH + 150 Accuracy class. MH + 15 C omplex resistance m odul of the primary circuit. Ohm 90 + 5 C omplex resistance a rgument of the primary circuit 0.45 + 0.02 and 0.55 + 0.02 C omplex resistance m odul of the secondary circuit. Ohm 400 + 20 C omplex resistance a rgument of the secondary circuit 0.1 Nominal Current. A 0.125 Normal frequency. Hz 50 MTBF: not less than 24500 Hours; Dimensions: 405x215x235mm Weight: 11kg; Warranty 12 mounths This device was also used in USSR and Russia army. So it has best quality. Longevity and permanence characteristic. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Complex mutual inductance box Р5017 is designed to control interchangeable differential transformer devices. Powered from AC frequency of 50 Hz. Measuring range of complex mutual inductance modulus M in range 12.99 mH. Measuring range of complex mutual inductance argument- from 4.5 to 10 if M is not less than 0.1 mH. Measuring range of complex residual mutual inductance modulus M 0 within ± 150mkH. Complex mutual inductance box Р5017 is designed to control interchangeable differential transformer devices. Powered from AC frequency of 50 Hz. Complex mutual inductance box Р5017 is us
$
23.23
Buy It Now
$2.74 Shipping
Condition: New
Location: China
$
167
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5101 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5101 1mkH 0.4 1 1 Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170 x 170 x 205mm; Weight: 3.5 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5101 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 1mkH Accuracy class 2 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform with a
$
4,000
Buy It Now
$999.99 Shipping
Condition: New – Open box
Location: Ukraine
$
649.99
Buy It Now
$135 Shipping
Condition: Used
Location: Ukraine
P597/7 Exemplary capacitor standard capacitance 100 0 pF General Radio.GenRad, IET analog of General Radio(GR. Genrad) IET Labs, Arco but has the same ... moreor better characteristics: Model Value Accuracy class Accuracyevaluationcapacity. Frequency range. Hz The value of loss tangent Height. Mm Diameter. Mm Weight. Kg P597/7 1000 pF 0.05 ± 0, 0 2 40-100000 5·10-5 260 180 11 Warranty 12 month. If you need such New item(not used) Please contact me, I will get it for your request. Please mind, that it may take some additional time) This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: Used. An old stock. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics: P597/1-9 is designed to be used as the exemplary steps in the chains of alternating current with a frequency from 40 to 100.000 Hz. Temperature +10 +35 ° C; Relative humidity up to 80% This device can be also named as: P-597. P-597, P 597, R597. R 597 R-597, р 597. Р- 597. Р 597 capacitor standard. Capacitors standard. Standard capacitance. Laboratory standard, high precision capacitor. Etalon capacitor. Photos If necessary we can take photos of a device from various angles. Technical Documentation In case you didn't find in technical specifications for the device all necessary information you are interested in. Feel free to contact me. I will look through the technical documentation for the device and I will be happy to consult you. Also I may speak directly with the manufacturer and find out more specific information about this product. If some technical parameters for the device(error. Accuracy, measuring range, operating voltage and fre
$
167
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
P5106 or P596 Unavalued Standard inductors types analog of General Radio(GR. GenRad 1482) Marconi, HP, IET Labs, but have the same or better characteristics: ... moreModel Value Accuracy depending on the nominal frequency. 1kHz 0.5; 1.5; 2.5; 5; 10 kHz 0.08; 50. 100 kHz P5106 500mkH 0.025 0.05- Technical characteristics: This device is desined to be used as part of the measuring circuits of alternating current frequency from 0.08 kHz to 100 kHz. Dimensions: 170x170x205mm; Weight: 4 kg; Operating temperature: 1-40 °С; Relative humidity: 30- 80% Atm. pressure: 84-106 kPa(630-800 mmHg) Warranty 12month. Inductance standard Р5106 esigned to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Inductance nominal value 500 mkH Accuracy class 0.05 Fixed certification frequencies 1 kHz. 10 kHz. 50kHz. 100kHz. Inductance unequivocal standard is designed to be used as an element of AC measuring schemes of frequency from 0.08 kHz to 100 kHz. Application area– laboratories of research institutes. Industrial enterprises and metrological services. Inductance standard- general industrial and export version) is designed to be used in moderate climate conditions, in dry heated rooms at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 25 ° C; Inductance standard- 04.1- general climate version) is designed to be used in both, dry and humid tropical climate, in closed and air-conditioned or partially air-conditioned rooms at a temperature of 1 to 40 ° C and relative humidity up to 80% at 25 ° C(GOST 15150) Technical characteristics Acceptable basic error limit. Expressed in percentage of inductance standards nominal value is equal to amount determined by the formula: δ = ± K where K- standards accuracy class. Normal using conditions of inductance standard: ambient temperature(20 ± 5) ° C; relative humidity 30-80% atmospheric pressure 84-106 kPa(650-800 mm.Hg) normal frequency(1 ± 0.1) kHz; current up to maximum; sinusoidal waveform w
$
333.99
Buy It Now
$85 Shipping
Condition: Used
Location: Ukraine
P597/3 Exemplary capacitor standard capacitance 10 0 pF General Radio.GenRad, IET analog of General Radio(GR. Genrad) IET Labs, Arco but has the same ... moreor better characteristics: Model Value Accuracy class Accuracyevaluationcapacity. Frequency range. Hz The value of loss tangent Height. Mm Diameter. Mm Weight. Kg P597/2 100 pF 0.05 ± 0, 0 2 40-100000 5·10-5 165 180 5 Warranty 12 month. If you need such New item(not used) Please contact me, I will get it for your request. Please mind, that it may take some additional time) This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristic. Condition: Used. An old stock. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration certificate from Government Standardization Institute( +145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Capacitance standard Р597 designed to be used as standard or AC circuits measurement element. Capacitance standard Р597 designed to be used as exemplary standard in AC circuits with the frequency from 40 to 100.000 Hz. Capacitance standard Р597 is used at an ambient temperature of 10 ° to 35 ° C and relative humidity up to 80% at 30 ° C) In terms to mechanical stress Capacitance standard Р597 applies to ordinary devices. The nominal values of capacity are listed by groups in the table. The deviation of the actual capacitance(in percent of nominal value) at a frequency of 1000 Hz does not exceed ±(0.05 + Δ/ C) for C = 1 ÷ 4000pF. A = ± 0.1% determined from the capacitance values) for C = 0.01 ÷ 1mkF. Dielectric tangent loss at a frequency of 1000 Hz is less than 5• 10-5- for C = 1 ÷ 4000pF and 1• 10-3- for C = 0.01 ÷ 1.0 mkF. Capacitance value changes at the frequency deviation of 1000 Hz does not exceed ±(0.05 + 0.5/ C) for C- 1
$
178
Buy It Now
$15 Shipping
Condition: New
Location: China
$
117.7
Buy It Now
$6.89 Shipping
Condition: New
Location: China
$
15.96
Buy It Now
$2.74 Shipping
Condition: New
Location: China
$
184.95
Buy It Now
$15 Shipping
Condition: New
Location: China
$
17.82
Buy It Now
Free Shipping
Condition: New
Location: United Kingdom
$
10.96
Buy It Now
$2.6 Shipping
Condition: New
Location: China
$
6.87
Buy It Now
$2.74 Shipping
Condition: New
Location: Hong Kong
$
24.78
Buy It Now
Free Shipping
Condition: New
Location: United Kingdom
$
6.87
Buy It Now
$2.74 Shipping
Condition: New
Location: China
$
15.19
Buy It Now
$0 Shipping
Condition: New
Location: China
$
4.78
Buy It Now
$14.36 Shipping
Condition: New
Location: United Kingdom
$
10.24
Buy It Now
$71.4 Shipping
Condition: New
Location: United Kingdom
$
8.39
Buy It Now
$13.76 Shipping
Condition: New
Location: United Kingdom
$
17.34
Buy It Now
$68.86 Shipping
Condition: New
Location: United Kingdom
$
7.39
Buy It Now
$14.37 Shipping
Condition: New
Location: United Kingdom
$
999
Buy It Now
$25 Shipping
Condition: Used
Location: West Hurley,NY,USA
$
6.87
Buy It Now
$13.76 Shipping
Condition: New
Location: United Kingdom
$
17.39
Buy It Now
$0 Shipping
Condition: New
Location: China
$
2,999.99
Buy It Now
$0 Shipping
Condition: Used
Location: Cypress,TX,USA
About Us How We Work Contact Us Megown Test& Measurement Inc. Megown Test& Measurement Inc. 4400 Yankee Hill Road Rocklin. CA. USA Tel: 1-916-773-5010 ... moreTel: 1-800-442-5835 Fax: 1-916-773-4126"For all Your Test and Measurement Needs! Item Description You are looking at a Keysight/ Agilent/ HP 85064A Type N RF Electronic(ECAL) Calibration Kit. This unit has been tested and will come with a 30 day Warranty. Cosmetics: Scratches here and there Very clean unit Specifications: Keysight/ Agilent/ HP Model# 85064A Serial# US34480134/ Asset# 216135 Type N RF Electronic Calibration Kit 30 day WARRANTY Frequency Range: 1 to 18 GHz Option 001: Type N Lowband Module. 45 MHz to 2 GHz Full two-port calibration with a single-connection for easy calibrations, Precision slotless connectors provide greater measurement accuracy and repeatability than standard connectors, Simple user interface, Compatible with Keysight network analyzers, Straight-forward noninsertable calibrations, Includes Wrench. Wooden Box and ECAL Module Product Details: The Keysight 85064A electronic calibration system consists of a control unit and a connector specific calibration module. The control unit provides communication and control for the calibration module. The Keysight 85064A is an electronic calibration module that must be controlled by the Keysight 85060C control unit. Electronic calibration(ECal) is a precision. Single-connection, one- or two-port calibration technique that uses fully traceable and verifiable electronic standards. ECal provides repeatable, accurate measurements while bringing convenience and simplicity to your daily calibration routine. ECal replaces the traditional calibration technique which uses mechanical standards. With mechanical standards. You are required to make numerous connections to the test ports for a single calibration. These traditional calibrations require intensive operator interaction, which is prone to errors. With ECal, a full two-port calibration can be accomplished with a single connection o
$
8.61
Buy It Now
Free Shipping
Condition: New
Location: United Kingdom
1 2 3 4 5 6 7 8 9 10 11 12 13 14
 In