Ohm Standard Resistor Optics Positioner Laser Optics Bin 3 Unknown Optics Laser Optical Bin 3 Current Calibrator Calibrator Standard Pneumatic Calibrator Cable For Accelerometer Omega Calibrator Ea Optics Thermocouple Calibrator Optics Bin 4 Standard Inductor Unknown Application Calibrator 0 Piezoelectric Accelerometer Calibration Vibration Optical Bin 1 Optical Bin 3 Precision Calibrator Loop Calibrator Resistance Standard Voltage Standard Dead Weight Tester Tester Calibrator Resistance Decade Multifunction Calibrator Vintage Microscope Objective Guildline Calibrator Tested Frequency Standard Oscillator Ac Calibrator Portable Calibrator Process Calibrator Laser Optics Bin 1 Standard Capacitor Altek Calibrator Dc Calibrator Altek Model Decade Resistance Decade Resistance Box Hp Calibration Kit Ohm Resistance Standard Mil Spec Laser Optics Decade Resistor Mil Spec Laser Optical Optics Bin 3 Torque Tester Fluke Standard Esi Resistor Druck Calibrator Optics Assembly Huge Optics Dead Weight Pcb Accelerometer Fluke 5100B Transmation Pps Mm Dia Fl Optics Window Ametek Calibrator Dc Voltage Calibrator Optical Mounted Prism Laser Optics Optics Coated Lens Lens Mil Spec Laser Optics Pressure Calibration Flow Calibrator Calibrator Type Calibrator Thermometer Documenting Process Calibrator Fluke 5100B Calibrator Optics Fixture Iet Digital Calibrator Hp Calibrator Newport Optics 10-32 For Accelerometer Optics Prism Rubidium Frequency Standard Rubidium Standard Transmation Druck Dpi Optics Device Rubidium Frequency Mm Laser Optics Standard Resistor Temperature Calibrator Standard Cell Rtd Calibrator Bliley Quartz Pcb Piezotronics Piezotronics Quartz Crystal Frequency Altek Calibration Fixture Calibrator Hart Leitz Wetzlar Germany Microscope Frequency Calibrator Pure Chemical Coated Laser Optics Tektronix Calibration Calibration Model Calibrator Free Shipping Nist Calibrator Microscope Ocular Genrad Gr Gr General Radio Genrad Pressure Module Optical Prism Optics Coated Filter Rubidium Optics Glass Melles Griot Optics Voltage Calibrator Hart Scientific Torque Calibrator Thermometer Calibrator Dc Voltage Standard Programmable Calibrator Dry Calibrator Optics Lens Convex Datron Transmation Model Meter Calibrator Bliley Calibration System Torque Analyzer Filter Laser Optics Quartz Oscillator Optical Coated Optics Beam Splitter Calibrator Source Radio Genrad Vibration Sensor Verification Kit Calibrator Module Optics Micrometer Endevco Nice Optics Ametek Jofra Infrared Laser Optics Lamp Microscope Bin 11 Ea Lamp Dc Reference Standard Resonator Frequency Reference Standard Endevco Meggitt Accelerometer Accelerometer Pressure Charge Amplifier Guildline Standard Resistor- Accuracy 9330 Portable Pressure Calibrator Electro Scientific Industries Voltage Current Calibrator Calibration Standard Decade Capacitor Endevco Model Range Calibrator Ge Druck Dpi Bin Pmel Dead Weight Pressure Meter Calibration Resistance Calibrator Fluke 5700A Microscope Objective Optics Valhalla Scientific Leeds Northrup Primary Flow Calibrator Calibrator Multimeter Japan Optics Frequency Standard Calibrator Signal Resistor 100 Mirror Laser Optical Low Noise Cable Japan Microscope Beam Splitter Bliley Crystal Multifunction Process Calibrator Short Load Voltage Divider Dry Block Calibrator Mirror Laser Optics Torque Meter Nist Mirror Filter Optics Flat Calibrator Pump Transfer Standard Chip Resistor Calibration Test Datron Wavetek Analyzer Calibrator Positioner Stage Efratom Genrad Precision Decade Bin 7 Fluke Hart Scientific
 In 
 
Order by: 
Available to: 
Price: 
 - 
$
2,999.46
Buy It Now
$999.99 Shipping
Condition: New – Open box
Location: Ukraine
High precision capacitance AC bridge P5026(Set) Multivalued. High-frequency decade capacitance box capacitor standard. AC bridge analog of General Radio(GR. ... moreGenRad) IET Labs, but has the same or better characteristics. AC bridge Р5026М is designed to measure capacitance and dielectric tangent loss of high-voltage industrial insulation for a"direct" both outputs of the measuring object isolated from the"earth" and" inverted" one output of the measured object is connected to"earth" schemes under operational conditions. Directly on the installation location, as well as measurements of"direct" scheme in the laboratory capacity and dielectric tangent loss of various insulating materials and condensers at 50 and 60Hz. P5026 Set includes: 1. P5026 AC bridge- 1psc. 2. Q5122 potential protector- 1set. 3. P5069 condenser block- 1psc. 4. P5023 Standart air condenser- 1 set. 5. Solid dielectrics testing electrodes- 1 set. 6. Power cord- 1psc. 7. Cables- 1 psc. 8. Manual and docs. Technical characteristics: M easurement range С х tgδ х 10 pF-1000 pF 1∙10-4-0.1 100 pF-10000 pF 1∙10-4-1.0 10 4 pF-2∙10 4 pF 2∙10 4 pF-10 5 pF 10 5 pF-10 6 pF 5∙10-4-1.0 100 pF-10000 pF 5∙10-3-1.0(10 4 pF-10 5 pF)10 5 pF-10 6 pF) 650 pF-2∙10 5 pF 5∙10-3-0.1 6500 pF-2∙10 6 pF 5∙10-3-1.0 2∙10 6 pF-5∙10 8 pF Measurement range Operating voltage Measurement schem e С х tgδ х 10 pF-1000 pF 1∙10-4-0.1 5 kV-10 kV« straight» with F 5122 and Р5069 100 pF-10000 pF 1∙10-4-1.0 3 kV-10 kV 10 4 pF-2∙10 4 pF 2∙10 4 pF 10 5 п pF 3 kV-5 kV« straight» with F 5122 10 5 pF-10 6 pF 5∙10-4-1.0 100 pF-10000 pF 5∙10-3- 1.0 3 kV-10 kV« straight» with« turned back» 10 4 pF-10 5 pF)10 5 pF-10 6 pF) 650 pF 2∙10 5 pF 5∙10-3- 0.1 0.1 kV« straight» 6500 pF-2∙10 6 pF 5∙10-3-1.0 2∙10 6 pF-5∙10 8 pF MTBF not less than: 5250 hours; The average service at least: 6 years; Dimensions: 540 x 280 x 380mm; Weight: 22kg. Warranty 12 month. AC Bridge Р5026М consists of the following components
$
550
Buy It Now
$90 Shipping
Condition: New – Open box
Location: Ukraine
$
3,933
Buy It Now
$175 Shipping
Condition: New – Open box
Location: Ukraine
P5083 Multifunctional. Multivalued decade resistance box. Bridge, resistor. Potentiometer analog of: General Radio(GenRad) LEEDS& NORTHRUP, ESI, IET ... moreLabs, GR, Yokogawa, Shallcross, Tinsley& Co, Shallcross, Leeds& Northrup, L&N, Extech, EMCO, AEMC devices. But has the same or better characteristics: AC Bridge P5083 is an autonomous measuring device for general industrial purposes and designed for automatic measurements of: capacitance C. Inductance L. Active resistance R. Tangent loss tgδ( Q Qr) tangent angle of phase shift tgφ( Q Qc and QL) of measuremed objects. And also a percentage deviation of measured object with further presentation of measurement results in digital form. AC bridge P5083 can be used for: Scientific researches; Metrological measuring instruments attestation; Quality control of electrical and radiotechnical products; Nonelectrical values measurement with a use of nonelectrical values transformers into one of measured values. Min. Value of accuracy class: With an external model of calibration) 0.02/0,002(0.005/0,0002) The range of measured values ​​: resistance. Ohm from 1·10-5 to 1·10 10 capacitance from 1·10-16 to 10 inductance from 1·10-10 to 1·10 7 angle shift tangent(tg φ) from ± 1·10-5 to ± 1·10 +5 deviation percentage. from ± 0.001 to ± 100 frequency.KHz(3000 discrete frequencies installed) from 0.1 to 100 Discrete digital frame(on low range of measurements) active resistance. Ohm 1·10-5 capacitance 1·10-16 inductance 1·10-10 AC range of values. On-site measurements(dependingon the measuredvalues​​) V. From 0.01 to 30 Dimensions: 440 x158x405mm; Weight: 16 kg. Warranty 12mounth. Technical characteristics of AC bridge P5083: D epending on frequency and voltage of measurement object. Values measured by the AC bridge correspond to those shown in Table 1; Table1 Main Additional main derivative C Cp Rp tgδ c(Q R) Cs Rs L Lp Rp tgδ L(Q R) Ls Rs R Rp Cp tgδ c(Q C) Lp tgδ L(Q L) Rs Cs tgδ c(Q C) Ls tgδ L(Q L)
$
420.99
Buy It Now
$170 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
595.99
Buy It Now
$190 Shipping
Condition: Used
Location: Ukraine
P593 Multivalued decade inductance box. Inductor standard set is analog of General Radio(GR. GenRad) IET Labs, but has the same or better characteristics. ... moreInductance standard P593 d esigned for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Standard’s nominal value of inductance 0.01 mkH- 100mH Accuracy class: 1; 2; 5 Valued Inductance standard P593(hereinafter- standard) are designed for use as an AC element in measuring systems with frequency of 1 kHz to 10000kHz. Inductance standard P593 designed for use in moderate climate conditions in dry heated rooms at ambient temperature of 10 to 35 ° C and relative humidity up to 80% at 25 ° C. P593 a set of: 15 standard inductors; Nominal value from 0.01mkH to 100mH; Accuracy class: 1. 2, 5; Accuracy of the attestation: from 0.2; Full average lifespan- at least 10 years; Dimensions: 100x150mm for more 1mkH; 40x160mm for less 0.3 mkH; 490x335x185mm- whole case; Weight: 1 standart- 0.7kg; Whole set- 15kg; Warranty 12mounth. Technical characteristic of Decade inductance box inductor standard set type P593: Nominal Value of inductance Accuracy class Normal Frequency KHz Max Current A Max Voltage V Q Q/Frequency KHz 100 mH 1 1 0.010 5.000 70 30 30 mH 1 1 0.010 1.000 40 30 10 mH 1 1 0.010 0.500 130 100 3 mH 1 1 0.010 0.100 160 100 1 mH 1 1 0.010 0.050 200 300 300 mkH 1 1 0.010 0.020 140 300 100 mkH 1 1 0.010 0.005 200 1000 30 mkH 1 1 0.250 0.050 130 1000 10 mkH 1 1 0.250 0.020 210 3000 3 mkH 1 100 0.250 0.500 180 3000 1 mkH 2 100 0.250 0.100 200 10000 0.3 mkH 2 100 0.500 0.050- 0.1 mkH 2 100 0.500 0.020- 0.03 mkH 5 100 0.500 0.005- 0.01 mkH 5 100 0.500 0.002- Technical characteristics Inductance standard P593 correspond to GOST 21175. Inductance standard nominal value(L) accuracy classes(K) Normal frequency(f) attestation fixed- frequencies. Maximum current values(I) maximum operating voltage values(U) lowest values quality factor(Q) for frequencies f shown in Table 1. Acceptable basic error limit. Sh
$
333
Buy It Now
$70 Shipping
Condition: New – Open box
Location: Ukraine
Inductance standard P547. Analog of Lutron. Advantest. Avtech, HP Agilent. NoiseCom, General Radio. Boonton, Anritsu, Fluke and general Electric, but ... morehas the same or better characteristics. This device can be used for wide measurement range. For sale is 1 of 4 devices. Please choose on from the table. Is designed to be used as a inductance standard in AC circuits with a maximum operating frequency 1500- 10000 Hz. Depending on inductance standard nominal value. Nominal value: 1 H. 0.1 H. 0.001 H. 0.0001 H Accuracy: 0.1% Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Technical characteristics of device inductance standard P547: Inductance standard P547 is designed to be used as inductance standard in AC circuits with a maximum operating frequency 1500- 10000 Hz, depending on inductance standard nominal value. Inductance standard P547 is produced with the following nominal values: 1 H. 0.1 H. 0.001 H. 0.0001 H. Inductor coil P547 is designed for operation at temperatures of 10 ° C to +35 ° C and relative humidity up to 80% Technical characteristics Parameters Parameters and characteristics value Note Deviation from nominal value a) ± 0.1% for all inductance values ​​ and in frequency range of not more than: L, H 1 0. 1 0. 01 0. 001 and 0. 0001 Hz max. 500 1500 5000 10000 b) inductance change at higher frequency relative to maximum operating frequency for"a" does not exceed 0.2% at L, H 1 0. 1 0. 01 Hz max. 1000 3000 10000 Ohm resistance do not exceed L H 1 0. 1 0. 01 0. 001 0. 0001 On standards indicated resistance at t = +20 ° C r ~ Ohm 140 20 1. 5 0
$
4,000
Buy It Now
$999.99 Shipping
Condition: New – Open box
Location: Ukraine
$
390
Buy It Now
$140 Shipping
Condition: New – Open box
Location: Ukraine
P5017 Multivalued decade of mutual inductance. Inductance box, inductor standard set is analog of General Radio(GR, GenRad) IET Labs, but has the same ... moreor better characteristics: Variation range. MH + 12.99 Acceptable basic error limit. MH +(14х10-3 + 1.1х10-3 M) Inductance variation range From 4.5 to 10 Acceptable basic error limit. Deg + 0.4( M 0.1 mH) Variation range of residual mutual inductance. MH + 150 Accuracy class. MH + 15 C omplex resistance m odul of the primary circuit. Ohm 90 + 5 C omplex resistance a rgument of the primary circuit 0.45 + 0.02 and 0.55 + 0.02 C omplex resistance m odul of the secondary circuit. Ohm 400 + 20 C omplex resistance a rgument of the secondary circuit 0.1 Nominal Current. A 0.125 Normal frequency. Hz 50 MTBF: not less than 24500 Hours; Dimensions: 405x215x235mm Weight: 11kg; Warranty 12 mounths This device was also used in USSR and Russia army. So it has best quality. Longevity and permanence characteristic. Condition: NEW(not used. An old stock) Tested and 100% workable. If necessary. We can provide calibration certificate from Government standardization institute(+145-265usd) Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance. Capacitance and inductance standards, decade box and other etalons. If you haven’t found the needed item in my listing. Please contact me. I’ll try to help you. Complex mutual inductance box Р5017 is designed to control interchangeable differential transformer devices. Powered from AC frequency of 50 Hz. Measuring range of complex mutual inductance modulus M in range 12.99 mH. Measuring range of complex mutual inductance argument- from 4.5 to 10 if M is not less than 0.1 mH. Measuring range of complex residual mutual inductance modulus M 0 within ± 150mkH. Complex mutual inductance box Р5017 is designed to control interchangeable differential transformer devices. Powered from AC frequency of 50 Hz. Complex mutual inductance box Р5017 is us
1
 In 

Past Items  
 
P331 Coil. Unevalued resistance standard resistor. USED. P331 resistance standard resistor analog of LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 100 Ohm. For sale is one coil) I sold a more then 70 units of this devices types. That is why now in stock I had units with scratches. Cracks and cleavage of the case and panel. Please take a look the picture. Also I had no enough units with class 0.01. That is why I can send you unit with class 0.02. I will choose the best one used device I had in my stock. It will be tested and 100% workable. I give you a warranty for 1 year. I Also I had new devices please take a look them by the link: http:stores.ebay.com/electro-radio-device-high-precision/Resistance-Standards-Boxes-i.html?fsub=3003745013. Accuracy class: 0.01% It is max error(accuracy) ... morewhich is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 100 P331 100 8 20 2 20 10 0.1 0.025 0.1 1000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) Warranty: 12 month. Electrical resistance coil P331 Represents an exemplary resistance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Nominal
P321 Coil. Unevalued resistance standard resistor. NEW. P321 resistance standard resistor analog of LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 0.1 Ohm. For sale is one coil) Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. ... moreMohm max typical max typical max typical max typical 0.1 P321 100 15 20 3 20 4 0.1 0.05 3.2 1000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) Warranty: 12 month. Electrical resistance coil P321 Represents an exemplary resistance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Nominal resistance 0.1 Ohm; Accuracy class 0.01 Electrical resistance coil P321 represents an exemplary resistance standard and is designed for testing and fitting working resistance coils in DC circuits. As well as exemplary and working( laboratory) measuring devices. Electrical resistance coil P321 operates in liquid environment( capacitor oil, kerosene, o rganosilicium fluid) Acceptable resistance deviation of coils P321 from their nominal values caused by adjustment inaccuracy at temperature of 20°C and power not exceeding nominal: for accuracy class 0.01 is not more th
P321 or P331 Coil. Unevalued resistance standard resistor. P321 or P331 resistance standard resistor analog of LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 1 or 10 or 100 or 1000 or 10000 or 100000 Ohm. For sale is one of coils. You may choose a value for your consideration) I sold a more then 70 units of this devices types. That is why now in stock I had units with scratches. Cracks and cleavage of the case and panel. Please take a look the picture. Also I had no enough units with class 0.01. That is why I can send you unit with class 0.02. I will choose the best one used device I had in my stock. It will be tested and 100% workable. I give you a warranty for 1 year. Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the ... morevalue. Temperature resistance change, Stability per year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 1 P321 100 15 20 3 20 4 0.1 0.05 1 1000 10 P321 100 15 20 3 20 4 0.1 0.05 0.32 1000 100 P331 100 8 20 2 20 10 0.1 0.025 0.1 1000 1000 P331 100 8 20 2 20 10 0.1 0.025 0.032 1000 10000 P331 100 8 20 2 20 10 0.1 0.025 0.01 5000 100000 P331 100 8 20 2 20 10 0.1 0.025 0.0032 50000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) This device was also used in USSR and Russian army. So it has best quality. Longevity. And pe
P310 Coil. Unevalued resistance standard resistor. P310 resistance standard resistor analog of LEEDS& NORTHRUP. ESI, Honeywell, IET Labs device has the same or better characteristics: Nominal values 0.001 or 0.01( For sale is one of coils. You may choose a value for your consideration) I sold a more then 70 units of this devices types. That is why now in stock I had units with scratches. Cracks and cleavage of the case and panel. Please take a look the picture. Also I had no enough units with class 0.01. That is why I can send you unit with class 0.02. I will choose the best one used device I had in my stock. It will be tested and 100% workable. I give you a warranty for 1 year. Accuracy class: 0.01% It is max error(accuracy) which is given per manufacturer. It’s including nominal of the value. Temperature resistance change, Stability ... moreper year, stability per max current include and all other parameters which can affect the accuracy of the resistance standard) Real(typical) error: 0.002% = 20ppm; Accuracy of attestation(calibration uncertainty) 0.001% General characteristics(given by manufactur) Nominal Value Ohm Model Adjustment to Nominal. ppm) Stability per year. ppm) Resistance Change 15-25°C from 20°C, ppm/°C) Power Coef(ppm/mW) Max. Current. A Insulation resistance. Mohm max typical max typical max typical max typical 0.001 P310 100 20 20 5 20 5 0.1 0.05 32 1000 0.01 P310 100 20 20 5 20 5 0.1 0.05 10 1000 Nominal power: 0.1 Watt; Max power: 1 Watt; Dielectric strength of insulation: 2kV; Height: 170mm; Diameter: 110mm; Weight: 1kg; Hole for thermometer. Operation temperature: 15-25 °C; Relative humidity: 25 to 80% Atmosphere pressure: 84-106.7 kPa(630-800 mmHg) This device was also used in USSR and Russian army. So it has best quality. Longevity. And permanence characteristics. Condition: USED( lightly used. From an old stock) Item may have some visible scraches or bad paint etc. Tested and 100% workable. If necessary. The device can be calibrated and provided with the calibration cer
This is a CPI CO. RESISTOR STANDARD RESISTANCE 0.01 OHM( 0.01Ω) This item is in working condition and being sold as is. See photos for item details. Hawaii. Alaska, PR, will have added shipping surcharges, please ask for quote prior to bidding. Powered by The free listing tool. List your items fast and easy and manage your active items.
This is a RESISTOR STANDARD RESISTANCE P310 0.01 OHM( 0.01Ω) This item is in working condition and being sold as is. See photos for item details. Hawaii. Alaska, PR, will have added shipping surcharges, please ask for quote prior to bidding. Powered by The free listing tool. List your items fast and easy and manage your active items.
For sale lot of 3 pc. 0.001 0.01 0.1 Ohm Ω Lot of 3pc. Resistance Standard Resistor Accuracy 0.01% Technical characteristics: Accuracy class: 0.01% Nominal power: 0.1 Watt Max power: 1 Watt Dimensions 170x110 mm Weight: 0.9 kg If you need just one of coils. Just let me know or see my other items. I ship by air mail with tracking. Paypal Payment. 14 days Refund or Item Change!